Jeon-Wook Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeon-Wook Cho has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Byung-Bae Park
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Gyeongsangnam-do, Republic of Korea
2 shared publications - Dongmin Kim
Mechanical Engineering, Changwon National University, Changwon, Gyeongsangnam-do Korea (the Republic of) 51139
2 shared publications - Hae-Jong Kim
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Republic of Korea
2 shared publications - Hee-Suk Ryoo
Superconductivity Research Center, Korea Electrotechnology Research Institute, Changwon-si, Korea
2 shared publications - Kideok Sim
SuperGenics Company Ltd., Changwon, South Korea
2 shared publications - Sung-Kyu Kim
Korea Electrotechnology Research Institute, Changwon, South Korea
2 shared publications
Latest Publications
- Open Access
Electrical Breakdown Characteristics of LNG for Cryogenic Feedthrough Insulation Under Explosion-Proof Conditions
Reliable insulation design for LNG feedthroughs requires fundamental dielectric breakdown data obtained under cryogenic LNG conditions. However, such data remain scarce owing to the explosion-proof requirements imposed by the flammable nature of LNG. Furthermore, the influence of phase differences between LNG and NG on creepage dielectric breakdown behavior along insulation surfaces has received little attention. In this study, an explosion-proof cryostat and test facility compliant with the IEC 60079 series of standards were developed, and dielectric breakdown tests were conducted over a range of electrode gap distances and pressures. Two electrode configurations were employed: rod–plate electrodes for dielectric breakdown characterization in LN2 and LNG, and creepage electrodes for surface dielectric breakdown evaluation in NG and LNG. Experimental results show that LNG requires approximately 1–2 bar of additional operating pressure above that of LN2 to achieve equivalent dielectric strength. Moreover, LNG exhibited higher creepage dielectric breakdown voltages than NG under all test conditions, with the difference becoming more pronounced as pressure and creepage distance increased. Post-breakdown surface analysis revealed distinct differences in carbonization patterns between the two media. The findings of this study are expected to serve as fundamental reference data for the insulation design of LNG-based cryogenic feedthroughs.
Open AccessElectrical Breakdown Characteristics of LNG for Cryogenic Feedthrough Insulation Under Explosion-Proof Conditions
Reliable insulation design for LNG feedthroughs requires fundamental dielectric breakdown data obtained under cryogenic LNG conditions. However, such data remain scarce owing to the explosion-proof requirements imposed by the flammable nature of LNG. Furthermore, the influence of phase differences between LNG and NG on creepage dielectric breakdown behavior along insulation surfaces has received little attention. In this study, an explosion-proof cryostat and test facility compliant with the IEC 60079 series of standards were developed, and dielectric breakdown tests were conducted over a range of electrode gap distances and pressures. Two electrode configurations were employed: rod–plate electrodes for dielectric breakdown characterization in LN2 and LNG, and creepage electrodes for surface dielectric breakdown evaluation in NG and LNG. Experimental results show that LNG requires approximately 1–2 bar of additional operating pressure above that of LN2 to achieve equivalent dielectric strength. Moreover, LNG exhibited higher creepage dielectric breakdown voltages than NG under all test conditions, with the difference becoming more pronounced as pressure and creepage distance increased. Post-breakdown surface analysis revealed distinct differences in carbonization patterns between the two media. The findings of this study are expected to serve as fundamental reference data for the insulation design of LNG-based cryogenic feedthroughs.
- 17 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Increased Impedance of Wound HTS Power Cables by Quenching at a Shielding Layer for Fault Current Limiting Function
The use of high temperature superconducting (HTS) power cables is viable solution to address the growing demand for electric power, while ensuring low loss and high electric power transmission. Usually, HTS power cables and circular connection of substations reduce grid impedance, and the fault current is increased over the capacity of the circuit breaker. To protect the electric power grid, the fault current should be reduced below the allowable level. Of late, research on HTS power cables having fault current limiting (FCL) functions has increased. An inductive FCL HTS power cable uses the increased inductive impedance caused by magnetic flux leakage to a neighboring iron yoke when a quench occurs at the shielding layer of the cable core due to electromagnetic coupling with the conducting layer. Therefore, there is less heat generation, and the temperature rise is suppressed. In this study, we describe the increased inductive impedance and reduced fault current using a FCL model coil. To demonstrate the electromagnetic coupling between the conducting and shielding layers of the cable core, two concentrically wound REBCO coils were fabricated. The iron yoke inside the coil increases the inductive impedance when a fault current flows through the conducting layer, and quench occurs at the shielding layer. The results are used to develop an FCL HTS power cable with 154 kV, 600 MVA class.
- 17 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Increased Impedance of Wound HTS Power Cables by Quenching at a Shielding Layer for Fault Current Limiting Function
The use of high temperature superconducting (HTS) power cables is viable solution to address the growing demand for electric power, while ensuring low loss and high electric power transmission. Usually, HTS power cables and circular connection of substations reduce grid impedance, and the fault current is increased over the capacity of the circuit breaker. To protect the electric power grid, the fault current should be reduced below the allowable level. Of late, research on HTS power cables having fault current limiting (FCL) functions has increased. An inductive FCL HTS power cable uses the increased inductive impedance caused by magnetic flux leakage to a neighboring iron yoke when a quench occurs at the shielding layer of the cable core due to electromagnetic coupling with the conducting layer. Therefore, there is less heat generation, and the temperature rise is suppressed. In this study, we describe the increased inductive impedance and reduced fault current using a FCL model coil. To demonstrate the electromagnetic coupling between the conducting and shielding layers of the cable core, two concentrically wound REBCO coils were fabricated. The iron yoke inside the coil increases the inductive impedance when a fault current flows through the conducting layer, and quench occurs at the shielding layer. The results are used to develop an FCL HTS power cable with 154 kV, 600 MVA class.
- 31 July 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (5) , 2217-2225
Evaluation of Repeatability for the Measurement of DC Conductivity of HVDC XLPE Model Cables
- 31 July 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (5) , 2217-2225
Evaluation of Repeatability for the Measurement of DC Conductivity of HVDC XLPE Model Cables
- 31 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Design of a Novel Inductive Type Fault Current Limiting HTS Power Cable
In a power system, fault currents are on the rise and are becoming a common problem. Moreover, several methods for the restriction of fault currents can lead to the instability of power system. In the Republic of Korea, the Korea Electrotechnology Research Institute is carrying out the development of a 154 kV class high temperature superconductor (HTS) cable with a fault current limiting function since May 2017. In this project, a novel inductive type fault current limiting (IFCL) HTS power cable is proposed. This paper presents the design of an IFCL-HTS cable for a transmission system, whose principle is based on change in the distribution of magnetic fields around the cable using a quench of HTS shield layer. The results of the design and simulation for performance prediction are discussed in detail.
- 31 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Design of a Novel Inductive Type Fault Current Limiting HTS Power Cable
In a power system, fault currents are on the rise and are becoming a common problem. Moreover, several methods for the restriction of fault currents can lead to the instability of power system. In the Republic of Korea, the Korea Electrotechnology Research Institute is carrying out the development of a 154 kV class high temperature superconductor (HTS) cable with a fault current limiting function since May 2017. In this project, a novel inductive type fault current limiting (IFCL) HTS power cable is proposed. This paper presents the design of an IFCL-HTS cable for a transmission system, whose principle is based on change in the distribution of magnetic fields around the cable using a quench of HTS shield layer. The results of the design and simulation for performance prediction are discussed in detail.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Cryogenic Electrical Insulation Characteristics of Solid Insulator for the HVDC HTS Cable
A termination in the development of the HTS cable is very important because it requires thermal insulation as well as electrical insulation. We studied the cryogenic insulation properties of epoxy as a solid insulator for electrical and thermal design of 250kV class HVDC HTS cable terminations. Electrical characteristics of the epoxy is a crucial element in the electrical insulation design of the HVDC HTS cable termination. Therefore, we studied the characteristics of the breakdown and the surface discharge of the epoxy. And the results were compared with the characteristics of breakdown and surface discharge of FRP.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Cryogenic Electrical Insulation Characteristics of Solid Insulator for the HVDC HTS Cable
A termination in the development of the HTS cable is very important because it requires thermal insulation as well as electrical insulation. We studied the cryogenic insulation properties of epoxy as a solid insulator for electrical and thermal design of 250kV class HVDC HTS cable terminations. Electrical characteristics of the epoxy is a crucial element in the electrical insulation design of the HVDC HTS cable termination. Therefore, we studied the characteristics of the breakdown and the surface discharge of the epoxy. And the results were compared with the characteristics of breakdown and surface discharge of FRP.