Hae-Jong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hae-Jong Kim has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Seung-Won Lee
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Gyeongsangnam-do, Republic of Korea
6 shared publications - Byung-Bae Park
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Gyeongsangnam-do, Republic of Korea
3 shared publications - Ik-Su Kwon
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Gyeongsangnam-do, Republic of Korea
3 shared publications - Jang-Seob Lim
Division of MEC, Mokpo National Maritime University, Mokpo-si, South Korea
3 shared publications - Jin-Seok Lim
Power Cable Research Center, Korea Electrotechnology Research Institute, Changwon-si 51543, Gyeongsangnam-do, Republic of Korea
3 shared publications - Hee-Suk Ryoo
Superconductivity Research Center, Korea Electrotechnology Research Institute, Changwon-si, Korea
2 shared publications
Latest Publications
- Open Access
- 30 September 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (10) , 1877
Long-Term Field Monitoring of Biofouling Characteristics in the Yellow Sea off Jeju Island, South Korea
Biofouling on offshore wind farm substructures threatens operational reliability and raises maintenance demands, underscoring the need for effective antifouling strategies. This study presents a 27-month evaluation of fouling development on a conventional non-antifouling coating and self-polishing copolymer (SPC) systems at a South Korean offshore wind farm. Biofouling coverage was assessed through long-term image analysis, and surface energy was characterized via contact angle measurements. Species analyses identified successional communities dominated by barnacles, coralline algae, and bryozoa. The conventional coating showed rapid colonization, exceeding 90% coverage within 10 months, whereas the SPC systems exhibited superior performance by suppressing settlement, though their effectiveness declined over time. Quantitative analysis revealed a clear relationship between higher surface energy and increased fouling rates, highlighting material properties as a key factor in colonization. This study provides one of the first long-term quantitative datasets from South Korean waters, advancing understanding of biofouling dynamics and informing antifouling strategies for offshore wind infrastructure.
- 30 September 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (10) , 1877
Open AccessLong-Term Field Monitoring of Biofouling Characteristics in the Yellow Sea off Jeju Island, South Korea
Biofouling on offshore wind farm substructures threatens operational reliability and raises maintenance demands, underscoring the need for effective antifouling strategies. This study presents a 27-month evaluation of fouling development on a conventional non-antifouling coating and self-polishing copolymer (SPC) systems at a South Korean offshore wind farm. Biofouling coverage was assessed through long-term image analysis, and surface energy was characterized via contact angle measurements. Species analyses identified successional communities dominated by barnacles, coralline algae, and bryozoa. The conventional coating showed rapid colonization, exceeding 90% coverage within 10 months, whereas the SPC systems exhibited superior performance by suppressing settlement, though their effectiveness declined over time. Quantitative analysis revealed a clear relationship between higher surface energy and increased fouling rates, highlighting material properties as a key factor in colonization. This study provides one of the first long-term quantitative datasets from South Korean waters, advancing understanding of biofouling dynamics and informing antifouling strategies for offshore wind infrastructure.
- Open Access
Enhanced Clustering of DC Partial Discharge Pulses Using Multi-Level Wavelet Decomposition and Principal Component Analysis
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability. Conventional AC-based diagnostic methods, such as phase-resolved partial discharge analysis (PRPDA), are ineffective under DC conditions, emphasizing the need for waveform-based analysis. This study presents a novel clustering framework for DC PD pulses, leveraging multi-level wavelet decomposition and statistical feature extraction. Each signal is decomposed into multiple frequency bands, and 70 distinctive waveform features are extracted from each pulse. To mitigate feature redundancy and enhance clustering performance, principal component analysis (PCA) is employed for dimensionality reduction. Experimental data were obtained from multiple defect types and measurement distances using a 22.9 kV cross-linked polyethylene (XLPE) cable system. The proposed method significantly outperformed conventional time-frequency (T-F) mapping techniques, particularly in scenarios involving signal attenuation and mixed noise. Propagation-induced distortion was effectively addressed through multi-resolution analysis. In addition, field noise sources such as HVDC converter switching transients and fluorescent lamp emissions were included to assess robustness. The results confirmed the framework’s capability to distinguish between multiple PD types and noise sources, even in challenging environments. Furthermore, optimal mother wavelet selection and correlation-based feature analysis contributed to improved clustering resolution. This framework supports robust PD classification in practical HVDC diagnostics. The framework can contribute to the development of real-time autonomous monitoring systems for HVDC infrastructure. Future research will explore incorporating temporal deep learning architectures for automated PD-type recognition based on clustered data.
Open AccessEnhanced Clustering of DC Partial Discharge Pulses Using Multi-Level Wavelet Decomposition and Principal Component Analysis
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability. Conventional AC-based diagnostic methods, such as phase-resolved partial discharge analysis (PRPDA), are ineffective under DC conditions, emphasizing the need for waveform-based analysis. This study presents a novel clustering framework for DC PD pulses, leveraging multi-level wavelet decomposition and statistical feature extraction. Each signal is decomposed into multiple frequency bands, and 70 distinctive waveform features are extracted from each pulse. To mitigate feature redundancy and enhance clustering performance, principal component analysis (PCA) is employed for dimensionality reduction. Experimental data were obtained from multiple defect types and measurement distances using a 22.9 kV cross-linked polyethylene (XLPE) cable system. The proposed method significantly outperformed conventional time-frequency (T-F) mapping techniques, particularly in scenarios involving signal attenuation and mixed noise. Propagation-induced distortion was effectively addressed through multi-resolution analysis. In addition, field noise sources such as HVDC converter switching transients and fluorescent lamp emissions were included to assess robustness. The results confirmed the framework’s capability to distinguish between multiple PD types and noise sources, even in challenging environments. Furthermore, optimal mother wavelet selection and correlation-based feature analysis contributed to improved clustering resolution. This framework supports robust PD classification in practical HVDC diagnostics. The framework can contribute to the development of real-time autonomous monitoring systems for HVDC infrastructure. Future research will explore incorporating temporal deep learning architectures for automated PD-type recognition based on clustered data.
- Open Access
- 21 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 8106
Calculation of Aging Coefficient for Establishing Aging Condition Index of Thermoplastic Insulated Power Cables
The growing demand for direct current transmission emphasizes the need for advanced insulation suitable for high-capacity, long-distance applications. Thermoplastics, especially polypropylene, offer several advantages over conventional materials like XLPE (cross-linked polyethylene) and EPR (ethylene propylene rubber), including higher thermal stability, recyclability, and reduced space charge accumulation. However, due to the inherent rigidity and limited flexibility of PP, its mechanical aging becomes a critical factor in assessing its long-term reliability as a cable insulation. In this study, mechanical aging characteristics, specifically declines in tensile strength and elongation, were selected as key indicators of insulation aging. Accelerated aging tests were conducted at 90 °C, 110 °C, and 130 °C for up to 5000 h. The experimental data were fitted to exponential models to derive aging coefficients, which formed the basis for the proposed aging model and the ACI (aging condition index). The ACI enables quantitative assessment of the current insulation condition and estimation of the remaining lifetime until a predefined threshold (e.g., ACI = 0.5) is reached. These findings contribute to the development of condition-based maintenance strategies and long-term asset management for power cables, offering practical insights for improving the reliability of future power grid systems.
- 21 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 8106
Open AccessCalculation of Aging Coefficient for Establishing Aging Condition Index of Thermoplastic Insulated Power Cables
The growing demand for direct current transmission emphasizes the need for advanced insulation suitable for high-capacity, long-distance applications. Thermoplastics, especially polypropylene, offer several advantages over conventional materials like XLPE (cross-linked polyethylene) and EPR (ethylene propylene rubber), including higher thermal stability, recyclability, and reduced space charge accumulation. However, due to the inherent rigidity and limited flexibility of PP, its mechanical aging becomes a critical factor in assessing its long-term reliability as a cable insulation. In this study, mechanical aging characteristics, specifically declines in tensile strength and elongation, were selected as key indicators of insulation aging. Accelerated aging tests were conducted at 90 °C, 110 °C, and 130 °C for up to 5000 h. The experimental data were fitted to exponential models to derive aging coefficients, which formed the basis for the proposed aging model and the ACI (aging condition index). The ACI enables quantitative assessment of the current insulation condition and estimation of the remaining lifetime until a predefined threshold (e.g., ACI = 0.5) is reached. These findings contribute to the development of condition-based maintenance strategies and long-term asset management for power cables, offering practical insights for improving the reliability of future power grid systems.
- Open Access
- 19 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 3
Reliability Assessment of Statistical Distributions for Analyzing Dielectric Breakdown Strength of Polypropylene
Various statistical distributions, such as Weibull, log-normal, and exponential functions, are frequently employed to interpret the dielectric breakdown (BD) strength data of insulating materials, including cross-linked polyethylene, low-density polyethylene, polypropylene (PP), and polyethylene. This study aimed to determine a suitable statistical distribution for analyzing the dielectric BD strength data of PP insulators before and after thermal degradation. Dielectric BD strength tests were conducted on thermally deteriorated PP insulators under various degradation conditions. Additionally, a coefficient of determination was employed to assess the compatibility between the dielectric BD strength data and the statistical distribution of PP insulators before and after thermal degradation. The test results indicate that the coefficient of determination for alternating current BD strength data was 0.955 in the log-normal distribution before degradation and 0.929 in the Weibull distribution after degradation. Consequently, in the analysis of the PP insulation breakdown data, the log-normal distribution was found to be suitable for data before degradation, while the Weibull distribution was deemed suitable for data after degradation. These results can lead to lower errors in the power system design process, enhancing reliability when analyzing the BD strength data of insulation materials.
- 19 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 3
Open AccessReliability Assessment of Statistical Distributions for Analyzing Dielectric Breakdown Strength of Polypropylene
Various statistical distributions, such as Weibull, log-normal, and exponential functions, are frequently employed to interpret the dielectric breakdown (BD) strength data of insulating materials, including cross-linked polyethylene, low-density polyethylene, polypropylene (PP), and polyethylene. This study aimed to determine a suitable statistical distribution for analyzing the dielectric BD strength data of PP insulators before and after thermal degradation. Dielectric BD strength tests were conducted on thermally deteriorated PP insulators under various degradation conditions. Additionally, a coefficient of determination was employed to assess the compatibility between the dielectric BD strength data and the statistical distribution of PP insulators before and after thermal degradation. The test results indicate that the coefficient of determination for alternating current BD strength data was 0.955 in the log-normal distribution before degradation and 0.929 in the Weibull distribution after degradation. Consequently, in the analysis of the PP insulation breakdown data, the log-normal distribution was found to be suitable for data before degradation, while the Weibull distribution was deemed suitable for data after degradation. These results can lead to lower errors in the power system design process, enhancing reliability when analyzing the BD strength data of insulation materials.
- Open Access
- 24 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 43424-43434
Precision and Performance Evaluation of Accelerated Aging System for DC TP Power Cables
The demand and necessity of direct current (DC) has been increasing owing to large capacity and long distance power transmission. DC application of TP (thermal plastic) materials, which can increase the power transmission capacity compared to existing insulation materials, has been the primary focus of existing studies. This study presents the development of a highly reliable accelerated aging system that can implement the aging conditions of DC power cables. Moreover, we verify its reliability by testing TP model cables and analyzing the aging characteristics. Accordingly, we developed an accelerated aging system that can simulate thermal, electrical, and mechanical stresses collectively. We used the accelerated aging system to perform an accelerated aging test of the TP model cable for 40 cycles. The control precision of the accelerated aging system during the test was numerically calculated. The system was evaluated by using the conduction current and chemical characteristics of the aged TP model cables. The experimental results show that the precision of accelerated aging system is 1 % for 1 cycle. The conduction current of the aged TP model cables was increased by more than 100% before aging, thereby it is verified the performance of the system accelerates the aging of power cables. It is expected that the highly reliable accelerated aging system of power cables can be used to perform long-term reliability tests and as diagnostic technology during the development of DC power cables.
- 24 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 43424-43434
Open AccessPrecision and Performance Evaluation of Accelerated Aging System for DC TP Power Cables
The demand and necessity of direct current (DC) has been increasing owing to large capacity and long distance power transmission. DC application of TP (thermal plastic) materials, which can increase the power transmission capacity compared to existing insulation materials, has been the primary focus of existing studies. This study presents the development of a highly reliable accelerated aging system that can implement the aging conditions of DC power cables. Moreover, we verify its reliability by testing TP model cables and analyzing the aging characteristics. Accordingly, we developed an accelerated aging system that can simulate thermal, electrical, and mechanical stresses collectively. We used the accelerated aging system to perform an accelerated aging test of the TP model cable for 40 cycles. The control precision of the accelerated aging system during the test was numerically calculated. The system was evaluated by using the conduction current and chemical characteristics of the aged TP model cables. The experimental results show that the precision of accelerated aging system is 1 % for 1 cycle. The conduction current of the aged TP model cables was increased by more than 100% before aging, thereby it is verified the performance of the system accelerates the aging of power cables. It is expected that the highly reliable accelerated aging system of power cables can be used to perform long-term reliability tests and as diagnostic technology during the development of DC power cables.
- Open Access
Evaluation of Electrical Performance and Life Estimation of PPs for HVDC Power Cable
Demand and need for the application of high voltage direct current (HVDC) are increasing because of high capacity and long-distance transmission. Research on polypropylene (PP) that can increase the operation temperature compared to existing insulation is constantly being considered. This study aimed to evaluate the electrical performance and estimate the life of HVDC application of PP. In this study, a DC V-t characteristic tests were conducted on three types of PP sheets at a temperature of 110 °C. In addition, a life estimation formula based on the electrical stress was derived and the electrical performances were evaluated. The experimental results show that the life exponent of material mixed with block copolymer, homo polymer and high density polyethylene (HDPE) was 23 and the electrical performance was 17% better than block copolymer, thereby demonstrating the reliability and electrical performance for application of HVDC.
Open AccessEvaluation of Electrical Performance and Life Estimation of PPs for HVDC Power Cable
Demand and need for the application of high voltage direct current (HVDC) are increasing because of high capacity and long-distance transmission. Research on polypropylene (PP) that can increase the operation temperature compared to existing insulation is constantly being considered. This study aimed to evaluate the electrical performance and estimate the life of HVDC application of PP. In this study, a DC V-t characteristic tests were conducted on three types of PP sheets at a temperature of 110 °C. In addition, a life estimation formula based on the electrical stress was derived and the electrical performances were evaluated. The experimental results show that the life exponent of material mixed with block copolymer, homo polymer and high density polyethylene (HDPE) was 23 and the electrical performance was 17% better than block copolymer, thereby demonstrating the reliability and electrical performance for application of HVDC.
- 31 July 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (5) , 2217-2225
Evaluation of Repeatability for the Measurement of DC Conductivity of HVDC XLPE Model Cables
- 31 July 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (5) , 2217-2225
Evaluation of Repeatability for the Measurement of DC Conductivity of HVDC XLPE Model Cables
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Cryogenic Electrical Insulation Characteristics of Solid Insulator for the HVDC HTS Cable
A termination in the development of the HTS cable is very important because it requires thermal insulation as well as electrical insulation. We studied the cryogenic insulation properties of epoxy as a solid insulator for electrical and thermal design of 250kV class HVDC HTS cable terminations. Electrical characteristics of the epoxy is a crucial element in the electrical insulation design of the HVDC HTS cable termination. Therefore, we studied the characteristics of the breakdown and the surface discharge of the epoxy. And the results were compared with the characteristics of breakdown and surface discharge of FRP.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Cryogenic Electrical Insulation Characteristics of Solid Insulator for the HVDC HTS Cable
A termination in the development of the HTS cable is very important because it requires thermal insulation as well as electrical insulation. We studied the cryogenic insulation properties of epoxy as a solid insulator for electrical and thermal design of 250kV class HVDC HTS cable terminations. Electrical characteristics of the epoxy is a crucial element in the electrical insulation design of the HVDC HTS cable termination. Therefore, we studied the characteristics of the breakdown and the surface discharge of the epoxy. And the results were compared with the characteristics of breakdown and surface discharge of FRP.
- Open Access
Improved Direct Deadbeat Voltage Control with an Actively Damped Inductor-Capacitor Plant Model in an Islanded AC Microgrid
A direct deadbeat voltage control design method for inverter-based microgrid applications is proposed in this paper. When the inductor-capacitor (LC) filter output voltage is directly controlled using voltage source inverters (VSIs), the plant dynamics exhibit second-order resonant characteristics with a load current disturbance. To effectively damp the resonance caused by the output LC filter, an active damping strategy that does not cause additional energy loss is utilized. The proposed direct deadbeat voltage control law is devised from a detailed, actively damped LC plant model. The proposed deadbeat control method enhances voltage control performance owing to its better disturbance rejection capability than the conventional deadbeat or proportional-integral-based control methods. The most important advantage of the proposed deadbeat control method is that it makes the deadbeat control more robust by bringing discrete closed-loop poles closer to the origin. Simulation and experimental results are shown to verify the enhanced voltage control performance and stability of the proposed voltage control method.
Open AccessImproved Direct Deadbeat Voltage Control with an Actively Damped Inductor-Capacitor Plant Model in an Islanded AC Microgrid
A direct deadbeat voltage control design method for inverter-based microgrid applications is proposed in this paper. When the inductor-capacitor (LC) filter output voltage is directly controlled using voltage source inverters (VSIs), the plant dynamics exhibit second-order resonant characteristics with a load current disturbance. To effectively damp the resonance caused by the output LC filter, an active damping strategy that does not cause additional energy loss is utilized. The proposed direct deadbeat voltage control law is devised from a detailed, actively damped LC plant model. The proposed deadbeat control method enhances voltage control performance owing to its better disturbance rejection capability than the conventional deadbeat or proportional-integral-based control methods. The most important advantage of the proposed deadbeat control method is that it makes the deadbeat control more robust by bringing discrete closed-loop poles closer to the origin. Simulation and experimental results are shown to verify the enhanced voltage control performance and stability of the proposed voltage control method.
- 1 March 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 153 (1) , 012018
DC V-I characteristics of a HTS tape for a 600kJ SMES in an Oblique external magnetic field
The critical current and n-value of the HTS tape, which are important for the characteristic analysis of the 600kJ HTS SMES system, were studied, and based on the results of the study, the DC V-I characteristics of a model coil fabricated by the same HTS tape of a 500 m length conductor were analyzed. The result show that the measured critical current and n-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2, whereas the characteristics decreased for the whole range of the oblique magnetic field. The critical current of the coil, which was calculated based on the results of the study on a short sample conductor, corresponded to the obtained value, which means that the critical current and n-value of a conductor for an oblique magnetic field in an arbitrary direction in the HTS SMES system can be estimated only by using the DC V-I characteristics of a short sample conductor for parallel and perpendicular magnetic fields.
- 1 March 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 153 (1) , 012018
DC V-I characteristics of a HTS tape for a 600kJ SMES in an Oblique external magnetic field
The critical current and n-value of the HTS tape, which are important for the characteristic analysis of the 600kJ HTS SMES system, were studied, and based on the results of the study, the DC V-I characteristics of a model coil fabricated by the same HTS tape of a 500 m length conductor were analyzed. The result show that the measured critical current and n-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2, whereas the characteristics decreased for the whole range of the oblique magnetic field. The critical current of the coil, which was calculated based on the results of the study on a short sample conductor, corresponded to the obtained value, which means that the critical current and n-value of a conductor for an oblique magnetic field in an arbitrary direction in the HTS SMES system can be estimated only by using the DC V-I characteristics of a short sample conductor for parallel and perpendicular magnetic fields.