Cillian J. Keogh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Cillian J. Keogh has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
David Mulcahy
Department of Orthopaedic Surgery, Bon Secours Hospital, College Road, Cork, Ireland
2 shared publicationsJames A. Harty
Department of Trauma & Orthopaedic Surgery, Cork University Hospital and South Infirmary Victoria University Hospital, Wilton, Cork, Ireland
2 shared publicationsDavid E. Beverland
Musgrave Park Hospital, Stockman’s Lane, Belfast, BT9 7JB, Northern Ireland, UK
1 shared publication- David Keohane
Department of Orthopaedics, Tallaght University Hospital, Dublin, Ireland
1 shared publication Declan Reidy
Department of Trauma and Orthopaedic Surgery, Cork University Hospital/South Infirmary Victoria University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland
1 shared publication
Latest Publications
- Open Access
- 1 April 2021
- Published by Elsevier in Arthroplasty Today
- Vol. 8, 283-288.e1
Nontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty
- 1 April 2021
- Published by Elsevier in Arthroplasty Today
- Vol. 8, 283-288.e1
Open AccessNontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty
- Open Access
- 22 July 2020
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 32 (1) , 1-6
Polyethylene spinout in the Attune® Cruciate-Retaining Rotating-Platform (CR RP) total knee arthroplasty performed with a cruciate-sacrificing and measured-resection technique
Introduction: Polyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer’s recommendations for the Attune® Cruciate-Retaining Rotating-Platform (CR RP) knee design. Aim: To discuss the potential aetiology and prevention of spinout in the Attune® CR RP knee. Methods: We used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune® CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period. Results: There were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis. Conclusions: This study reports a higher incidence of PE spinout in the Attune® CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune® CR RP.
- 22 July 2020
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 32 (1) , 1-6
Open AccessPolyethylene spinout in the Attune® Cruciate-Retaining Rotating-Platform (CR RP) total knee arthroplasty performed with a cruciate-sacrificing and measured-resection technique
Introduction: Polyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer’s recommendations for the Attune® Cruciate-Retaining Rotating-Platform (CR RP) knee design. Aim: To discuss the potential aetiology and prevention of spinout in the Attune® CR RP knee. Methods: We used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune® CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period. Results: There were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis. Conclusions: This study reports a higher incidence of PE spinout in the Attune® CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune® CR RP.