Mariia Zakharova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mariia Zakharova has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Loes Irene Segerink
BIOS Lab‐on‐chip group University of Twente Enschede The Netherlands
5 shared publications - Albert van Den Berg
BIOS lab-on-a-chip group, University of Twente, Enschede, the Netherlands
2 shared publications - Andries D. van der Meer
University of Twente
2 shared publications - Danny J. M. van Galen
Vascularization Lab, Department of Biomechanical Engineering, Technical Medical Center, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
2 shared publications - Hai Le The
Physics of Fluids Group MESA+ Institute University of Twente 7522 NB Enschede The Netherlands
2 shared publications - Jeroen Rouwkema
Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 6 May 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (13) , 3233-3242
Switching to external flows: perturbations of developing vasculature within chicken chorioallantoic membrane
Not only the flow of liquid through vasculature, but also external fluid flows can affect the organization and maturation of vessels.
- 6 May 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (13) , 3233-3242
Open AccessSwitching to external flows: perturbations of developing vasculature within chicken chorioallantoic membrane
Not only the flow of liquid through vasculature, but also external fluid flows can affect the organization and maturation of vessels.
- Open Access
Switching to external flows: perturbations of developing vasculature within chicken chorioallantoic membrane
The impact of fluid flow shear stresses, generated by the movement of blood through vasculature, on the organization and maturation of vessels is widely recognized. Nevertheless, it remains uncertain whether external fluid flows outside of the vasculature in the surrounding tissue can similarly play a role in governing these processes. In this research, we introduce an innovative technique called superfusion-induced vascular steering (SIVS). SIVS involves the controlled imposition of external fluid flow patterns onto the vascularized chick chorioallantoic membrane (CAM), allowing us to observe how this impacts the organization of vascular networks. To investigate the concept of SIVS, we conducted superfusion experiments on the intact chick CAM cultured within engineered eggshell system, using phosphate buffered saline (PBS). To capture and analyze the effects of superfusion, we employed a custom-built microscopy setup, enabling us to image both superfused and non-superfused regions within the developing CAM. This study provides valuable insights into the practical application of fluid superfusion within an in vivo context, shedding light on its significance for understanding tissue development and manipulation in an engineering setting.
Open AccessSwitching to external flows: perturbations of developing vasculature within chicken chorioallantoic membrane
The impact of fluid flow shear stresses, generated by the movement of blood through vasculature, on the organization and maturation of vessels is widely recognized. Nevertheless, it remains uncertain whether external fluid flows outside of the vasculature in the surrounding tissue can similarly play a role in governing these processes. In this research, we introduce an innovative technique called superfusion-induced vascular steering (SIVS). SIVS involves the controlled imposition of external fluid flow patterns onto the vascularized chick chorioallantoic membrane (CAM), allowing us to observe how this impacts the organization of vascular networks. To investigate the concept of SIVS, we conducted superfusion experiments on the intact chick CAM cultured within engineered eggshell system, using phosphate buffered saline (PBS). To capture and analyze the effects of superfusion, we employed a custom-built microscopy setup, enabling us to image both superfused and non-superfused regions within the developing CAM. This study provides valuable insights into the practical application of fluid superfusion within an in vivo context, shedding light on its significance for understanding tissue development and manipulation in an engineering setting.
- Open Access
- 21 August 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (12) , 2100138
Transwell‐Integrated 2 µm Thick Transparent Polydimethylsiloxane Membranes with Controlled Pore Sizes and Distribution to Model the Blood‐Brain Barrier
Traditional Transwell inserts with track‐etched 10 μm thick polymer membranes have been intensively used for studying cellular barriers. However, their thickness hampers direct cell‐cell interaction between the adjacent cells which has been shown to critically influence the barrier formation. Therefore, here the effect of reduced distance between the cells by using fivefold thinner (2 μm) optically transparent polydimethylsiloxane (PDMS) membranes is studied and compared with polycarbonate (PC) membranes. The authors validate their applicability as an alternative substrate for the study of the blood–brain barrier by performing a monoculture of brain endothelial cells (hCMEC/D3) and co‐culture with astrocytes in Transwells. The PDMS membranes supported the cellular protrusions through the well‐defined pores and allowed control over cellular transmigration by varying the pore size. Cellular localization of tight and adherens junction proteins ZO‐1, Claudin‐5, and VE‐cadherin is similar to PC membranes while their expression levels are affected as a function of membrane material and co‐culture with astrocytes. Additionally, a permeability assay indicated tighter barrier formation on the PDMS membrane. These results suggest the potential use of 2 μm PDMS membranes for in vitro modeling of biological barriers with improved co‐culture models and enhanced visibility of the cell culture.
- 21 August 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (12) , 2100138
Open AccessTranswell‐Integrated 2 µm Thick Transparent Polydimethylsiloxane Membranes with Controlled Pore Sizes and Distribution to Model the Blood‐Brain Barrier
Traditional Transwell inserts with track‐etched 10 μm thick polymer membranes have been intensively used for studying cellular barriers. However, their thickness hampers direct cell‐cell interaction between the adjacent cells which has been shown to critically influence the barrier formation. Therefore, here the effect of reduced distance between the cells by using fivefold thinner (2 μm) optically transparent polydimethylsiloxane (PDMS) membranes is studied and compared with polycarbonate (PC) membranes. The authors validate their applicability as an alternative substrate for the study of the blood–brain barrier by performing a monoculture of brain endothelial cells (hCMEC/D3) and co‐culture with astrocytes in Transwells. The PDMS membranes supported the cellular protrusions through the well‐defined pores and allowed control over cellular transmigration by varying the pore size. Cellular localization of tight and adherens junction proteins ZO‐1, Claudin‐5, and VE‐cadherin is similar to PC membranes while their expression levels are affected as a function of membrane material and co‐culture with astrocytes. Additionally, a permeability assay indicated tighter barrier formation on the PDMS membrane. These results suggest the potential use of 2 μm PDMS membranes for in vitro modeling of biological barriers with improved co‐culture models and enhanced visibility of the cell culture.
- Open Access
- 15 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (10) , 2040-2049
Measuring barrier function in organ-on-chips with cleanroom-free integration of multiplexable electrodes
Transepithelial/transendothelial electrical resistance (TEER) measurements can be applied in organ-on-chips (OoCs) to estimate the barrier properties of a tissue or cell layer in a continuous, non-invasive, and label-free manner. Assessing the barrier integrity in in vitro models is valuable for studying and developing barrier targeting drugs. Several systems for measuring the TEER have been shown, but each of them having their own drawbacks. This article presents a cleanroom-free fabrication method for the integration of platinum electrodes in a polydimethylsiloxane OoC, allowing the real-time assessment of the barrier function by employing impedance spectroscopy. The proposed method and electrode arrangement allow visual inspection of the cells cultured in the device at the site of the electrodes, and multiplexing of both the electrodes in one OoC and the number of OoCs in one device. The effectiveness of our system is demonstrated by lining the OoC with intestinal epithelial cells, creating a gut-on-chip, where we monitored the formation, as well as the disruption and recovery of the cell barrier during a 21 day culture period. The application is further expanded by creating a blood–brain-barrier, to show that the proposed fabrication method can be applied to monitor the barrier formation in the OoC for different types of biological barriers.
- 15 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (10) , 2040-2049
Open AccessMeasuring barrier function in organ-on-chips with cleanroom-free integration of multiplexable electrodes
Transepithelial/transendothelial electrical resistance (TEER) measurements can be applied in organ-on-chips (OoCs) to estimate the barrier properties of a tissue or cell layer in a continuous, non-invasive, and label-free manner. Assessing the barrier integrity in in vitro models is valuable for studying and developing barrier targeting drugs. Several systems for measuring the TEER have been shown, but each of them having their own drawbacks. This article presents a cleanroom-free fabrication method for the integration of platinum electrodes in a polydimethylsiloxane OoC, allowing the real-time assessment of the barrier function by employing impedance spectroscopy. The proposed method and electrode arrangement allow visual inspection of the cells cultured in the device at the site of the electrodes, and multiplexing of both the electrodes in one OoC and the number of OoCs in one device. The effectiveness of our system is demonstrated by lining the OoC with intestinal epithelial cells, creating a gut-on-chip, where we monitored the formation, as well as the disruption and recovery of the cell barrier during a 21 day culture period. The application is further expanded by creating a blood–brain-barrier, to show that the proposed fabrication method can be applied to monitor the barrier formation in the OoC for different types of biological barriers.
- Open Access
- 27 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (17) , 3132-3143
Multiplexed blood–brain barrier organ-on-chip
The developed multiplexed chip contains 8 channels that can be accessed individually or simultaneously with increased throughput. The visual inspection of cells in the device was improved with our fabricated 2 μm-thick porous PDMS membrane.
- 27 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (17) , 3132-3143
Open AccessMultiplexed blood–brain barrier organ-on-chip
The developed multiplexed chip contains 8 channels that can be accessed individually or simultaneously with increased throughput. The visual inspection of cells in the device was improved with our fabricated 2 μm-thick porous PDMS membrane.