Imane Hammana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Imane Hammana has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alfons Pomp
Health Technology Assessment Unit, Centre Hospitalier de l'Université de Montréal, Montreal, QC, Canada
2 shared publications - Andrée Boucher
Department of Medicine, Université de Montréal, Montreal, Canada
2 shared publications - Ariel Yuhan Ong
Institute of Ophthalmology, University College London, London, UK
2 shared publications - Catherine Beauchemin
PeriPharm Inc., Montreal, Canada
2 shared publications - Danny Gauthier
Department of Ophthalmology, Centre Hospitalier de l'Université de Montréal, Montréal, QC, Canada
2 shared publications - Fares Antaki
Cole Eye Institute, Cleveland Clinic, Cleveland, USA
2 shared publications
Latest Publications
- Open Access
- 3 September 2024
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 9 (1) , e59867
Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study
Background: Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. Objective: We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. Methods: We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. Results: This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. Conclusions: Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.
- 3 September 2024
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 9 (1) , e59867
Open AccessImplementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study
Background: Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. Objective: We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. Methods: We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. Results: This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. Conclusions: Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.
- Open Access
- 24 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study (Preprint)
BACKGROUND Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. OBJECTIVE We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. METHODS We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. RESULTS This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. CONCLUSIONS Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.
- 24 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessImplementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study (Preprint)
BACKGROUND Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. OBJECTIVE We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. METHODS We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. RESULTS This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. CONCLUSIONS Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.
- Open Access
- 1 August 2020
- Published by Maad Rayan Publishing Company in International Journal of Health Policy and Management
- Vol. 11 (2) , 112-117
Experiences of Using Cochrane Systematic Reviews by Local HTA Units
This study evaluated the use of Cochrane systematic reviews (CSRs) by Quebec’s local health technology assessment (HTA) units to promote efficiency in hospital decision-making. An online survey was conducted to examine: Characteristics of the HTA units; Knowledge about works and services from the Cochrane Collaboration; Level of satisfaction about the use of CSRs; Facilitating factors and barriers to the implementation of CSRs evidence in a local context; Suggestions to improve the use of CSRs. Data accuracy was checked by 2 independent evaluators. Ten HTA units participated. From their implementation a total of 321 HTA reports were published (49.8% included a SR). Works and services provided by the Cochrane collaboration were very well-known and HTA units were highly satisfied with CSRs (80%-100%). As regards to applicability in HTA and use of CSRs, major strengths were as follow: Useful as resource for search terms and background material; May reduce the workload (eg, brief review instead of full SR); Use to update a current review. Major weaknesses were: Limited use since no CSRs were available for many HTA projects; Difficulty to apply findings to local context; Focused only on efficacy and innocuity; Cannot be used as a substitute to a full HTA report. This study provided a unique context of assessment with a familiar group of producers, users and disseminators of CSRs in hospital setting. Since they generally used other articles from the literature or produce an original SR in complement with CSRs, this led to suggestions to improve their use of CSRs. However, the main limit for the use of CRS in local HTA will remain its lack of contextualisation. As such, this study reinforces the need to consider the notion of complementarity of experimental data informing us about causality and contextual data, allowing decision-making adapted to local issues.
- 1 August 2020
- Published by Maad Rayan Publishing Company in International Journal of Health Policy and Management
- Vol. 11 (2) , 112-117
Open AccessExperiences of Using Cochrane Systematic Reviews by Local HTA Units
This study evaluated the use of Cochrane systematic reviews (CSRs) by Quebec’s local health technology assessment (HTA) units to promote efficiency in hospital decision-making. An online survey was conducted to examine: Characteristics of the HTA units; Knowledge about works and services from the Cochrane Collaboration; Level of satisfaction about the use of CSRs; Facilitating factors and barriers to the implementation of CSRs evidence in a local context; Suggestions to improve the use of CSRs. Data accuracy was checked by 2 independent evaluators. Ten HTA units participated. From their implementation a total of 321 HTA reports were published (49.8% included a SR). Works and services provided by the Cochrane collaboration were very well-known and HTA units were highly satisfied with CSRs (80%-100%). As regards to applicability in HTA and use of CSRs, major strengths were as follow: Useful as resource for search terms and background material; May reduce the workload (eg, brief review instead of full SR); Use to update a current review. Major weaknesses were: Limited use since no CSRs were available for many HTA projects; Difficulty to apply findings to local context; Focused only on efficacy and innocuity; Cannot be used as a substitute to a full HTA report. This study provided a unique context of assessment with a familiar group of producers, users and disseminators of CSRs in hospital setting. Since they generally used other articles from the literature or produce an original SR in complement with CSRs, this led to suggestions to improve their use of CSRs. However, the main limit for the use of CRS in local HTA will remain its lack of contextualisation. As such, this study reinforces the need to consider the notion of complementarity of experimental data informing us about causality and contextual data, allowing decision-making adapted to local issues.