APAlfons Pomp

Alfons Pomp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alfons Pomp has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study

    by Fares Antaki, Imane Hammana, Marie-Catherine Tessier, Andrée Boucher, Maud Laurence David Jetté, Catherine Beauchemin, Karim Hammamji, Ariel Yuhan Ong, Marc-André Rhéaume, Danny Gauthier, et al.

    Background: Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. Objective: We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. Methods: We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. Results: This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. Conclusions: Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.


  • Open Access

    Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study (Preprint)

    by Fares Antaki, Imane Hammana, Marie-Catherine Tessier, Andrée Boucher, Maud Laurence David Jetté, Catherine Beauchemin, Karim Hammamji, Ariel Yuhan Ong, Marc-André Rhéaume, Danny Gauthier, et al.

    BACKGROUND Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. OBJECTIVE We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. METHODS We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. RESULTS This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. CONCLUSIONS Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.

  • Health change awareness and its association with weight loss following bariatric surgery.

    by Michael B. Wolfe, Todd J. Williams, Elizabeth N. Dewey, James E. Mitchell, Alfons Pomp, Bruce M. Wolfe

    Objective: Patients' ability to judge health change over time has important clinical implications for treatment, but is understudied in longitudinal contexts with meaningful health change. We assess patients' awareness of health change for 5 years following bariatric surgery, and its association with weight loss.Method: Participants were part of the Longitudinal Assessment of Bariatric Surgery (N = 2,027). Perceived health change for each year was assessed by comparing it to self-reports of health on the SF-36 health survey. Participants were categorized as concordant when perceived and actual self-reported health change corresponded, and as discordant when they did not correspond. Results: Year-to-year concordance between perceived and actual self-reported health change occurred less than 50% of the time. Discordance between perceived and actual health was associated with weight loss following surgery. Discordant-positive participants who perceived their health change as more positive than was warranted lost more weight post-surgery and thus had lower body mass index scores than concordant participants. Conversely, discordant-negative participants who perceived their health as worse than what was warranted lost less weight post-surgery and thus had higher body mass index scores. Conclusions: These results suggest that recollection of past health is generally poor and can be biased by salient factors during recall. Clinicians are advised to use caution when retrospective judgments of health are utilized.


  • Five-year attrition, active enrollment, and predictors of level of participation in the Longitudinal Assessment of Bariatric Surgery (LABS-2) study

    by William F. Gourash, Wendy C. King, Eleanor Shirley, Amanda Hinerman, Faith Ebel, Alfons Pomp, Walter J. Pories, Anita P. Courcoulas