Juhui Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juhui Lee has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kwang Gi Kim
Department of Biomedical Engineering, Gachon University, Incheon, Republic of Korea
5 shared publications - Young Jae Kim
Gachon Biomedical & Convergence Institute, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea
3 shared publications - Soyoon Kwon
Department of Biomedical Engineering, College of Health Science, Gachon University, Incheon, Korea
2 shared publications - Doo-Ho Lee
Gachon University Gil Medical Center, Gachon University College of Medicine
1 shared publication - Doojin Kim
Department of Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
1 shared publication - Jaehun Yang
Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 8 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (22) , 2834
Deep Learning Model for Volume Measurement of the Remnant Pancreas After Pancreaticoduodenectomy and Distal Pancreatectomy
Background/Objectives: Accurate volumetry of the remnant pancreas after pancreatectomy is crucial for assessing postoperative endocrine and exocrine function but remains challenging due to anatomical variability and complex postoperative morphology. This study aimed to develop and validate a deep learning (DL)-based model for automatic segmentation and volumetry of the remnant pancreas using abdominal CT images. Methods: A total of 1067 CT scans from 341 patients who underwent pancreaticoduodenectomy and 512 scans from 184 patients who underwent distal pancreatectomy were analyzed. Ground truth masks were manually delineated and verified through multi-expert consensus. Six 3D segmentation models were trained and compared, including four convolution-based U-Net variants (basic, dense, residual, and residual dense) and two transformer-based models (Trans U-Net and Swin U-Net). Model performance was evaluated using five-fold cross-validation with sensitivity, specificity, precision, accuracy, and Dice similarity coefficient. Results: The Residual Dense U-Net achieved the best performance among convolutional models, with dice similarity coefficient (DSC) values of 0.7655 ± 0.0052 for pancreaticoduodenectomy and 0.8086 ± 0.0091 for distal pancreatectomy. Transformer-based models showed slightly higher DSCs (Swin U-Net: 0.7787 ± 0.0062 and 0.8132 ± 0.0101), with statistically significant but numerically small improvements (p < 0.01). Conclusions: The proposed DL-based approach enables accurate and reproducible postoperative pancreas segmentation and volumetry. Automated volumetric assessment may support objective evaluation of remnant pancreatic function and provide a foundation for predictive modeling in long-term clinical management after pancreatectomy.
- 8 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (22) , 2834
Open AccessDeep Learning Model for Volume Measurement of the Remnant Pancreas After Pancreaticoduodenectomy and Distal Pancreatectomy
Background/Objectives: Accurate volumetry of the remnant pancreas after pancreatectomy is crucial for assessing postoperative endocrine and exocrine function but remains challenging due to anatomical variability and complex postoperative morphology. This study aimed to develop and validate a deep learning (DL)-based model for automatic segmentation and volumetry of the remnant pancreas using abdominal CT images. Methods: A total of 1067 CT scans from 341 patients who underwent pancreaticoduodenectomy and 512 scans from 184 patients who underwent distal pancreatectomy were analyzed. Ground truth masks were manually delineated and verified through multi-expert consensus. Six 3D segmentation models were trained and compared, including four convolution-based U-Net variants (basic, dense, residual, and residual dense) and two transformer-based models (Trans U-Net and Swin U-Net). Model performance was evaluated using five-fold cross-validation with sensitivity, specificity, precision, accuracy, and Dice similarity coefficient. Results: The Residual Dense U-Net achieved the best performance among convolutional models, with dice similarity coefficient (DSC) values of 0.7655 ± 0.0052 for pancreaticoduodenectomy and 0.8086 ± 0.0091 for distal pancreatectomy. Transformer-based models showed slightly higher DSCs (Swin U-Net: 0.7787 ± 0.0062 and 0.8132 ± 0.0101), with statistically significant but numerically small improvements (p < 0.01). Conclusions: The proposed DL-based approach enables accurate and reproducible postoperative pancreas segmentation and volumetry. Automated volumetric assessment may support objective evaluation of remnant pancreatic function and provide a foundation for predictive modeling in long-term clinical management after pancreatectomy.
- Open Access
Deep Learning-Based Multi-Class Segmentation of the Paranasal Sinuses of Sinusitis Patients Based on Computed Tomographic Images
Accurate paranasal sinus segmentation is essential for reducing surgical complications through surgical guidance systems. This study introduces a multiclass Convolutional Neural Network (CNN) segmentation model by comparing four 3D U-Net variations—normal, residual, dense, and residual-dense. Data normalization and training were conducted on a 40-patient test set (20 normal, 20 abnormal) using 5-fold cross-validation. The normal 3D U-Net demonstrated superior performance with an F1 score of 84.29% on the normal test set and 79.32% on the abnormal set, exhibiting higher true positive rates for the sphenoid and maxillary sinus in both sets. Despite effective segmentation in clear sinuses, limitations were observed in mucosal inflammation. Nevertheless, the algorithm’s enhanced segmentation of abnormal sinuses suggests potential clinical applications, with ongoing refinements expected for broader utility.
Open AccessDeep Learning-Based Multi-Class Segmentation of the Paranasal Sinuses of Sinusitis Patients Based on Computed Tomographic Images
Accurate paranasal sinus segmentation is essential for reducing surgical complications through surgical guidance systems. This study introduces a multiclass Convolutional Neural Network (CNN) segmentation model by comparing four 3D U-Net variations—normal, residual, dense, and residual-dense. Data normalization and training were conducted on a 40-patient test set (20 normal, 20 abnormal) using 5-fold cross-validation. The normal 3D U-Net demonstrated superior performance with an F1 score of 84.29% on the normal test set and 79.32% on the abnormal set, exhibiting higher true positive rates for the sphenoid and maxillary sinus in both sets. Despite effective segmentation in clear sinuses, limitations were observed in mucosal inflammation. Nevertheless, the algorithm’s enhanced segmentation of abnormal sinuses suggests potential clinical applications, with ongoing refinements expected for broader utility.
- Open Access
- 31 January 2023
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 29 (1) , 84-88
Development of an Automatic Pill Image Data Generation System
Objectives: Since the easiest way to identify pills and obtain information about them is to distinguish them visually, many studies on image processing technology exist. However, no automatic system for generating pill image data has yet been developed. Therefore, we propose a system for automatically generating image data by taking pictures of pills from various angles. This system is referred to as the pill filming system in this paper.Methods: We designed the pill filming system to have three components: structure, controller, and a graphical user interface (GUI). This system was manufactured with black polylactic acid using a 3D printer for lightweight and easy manufacturing. The mainboard controls data storage, and the entire process is managed through the GUI. After one reciprocating movement of the seesaw, the web camera at the top shoots the target pill on the stage. This image is then saved in a specific directory on the mainboard.Results: The pill filming system completes its workflow after generating 300 pill images. The total time to collect data per pill takes 21 minutes and 25 seconds. The generated image size is 1280 × 960 pixels, the horizontal and vertical resolutions are both 96 DPI (dot per inch), and the file extension is .jpg.Conclusions: This paper proposes a system that can automatically generate pill image data from various angles. The pill observation data from various angles include many cases. In addition, the data collected in the same controlled environment have a uniform background, making it easy to process the images. Large quantities of high-quality data from the pill filming system can contribute to various studies using pill images.
- 31 January 2023
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 29 (1) , 84-88
Open AccessDevelopment of an Automatic Pill Image Data Generation System
Objectives: Since the easiest way to identify pills and obtain information about them is to distinguish them visually, many studies on image processing technology exist. However, no automatic system for generating pill image data has yet been developed. Therefore, we propose a system for automatically generating image data by taking pictures of pills from various angles. This system is referred to as the pill filming system in this paper.Methods: We designed the pill filming system to have three components: structure, controller, and a graphical user interface (GUI). This system was manufactured with black polylactic acid using a 3D printer for lightweight and easy manufacturing. The mainboard controls data storage, and the entire process is managed through the GUI. After one reciprocating movement of the seesaw, the web camera at the top shoots the target pill on the stage. This image is then saved in a specific directory on the mainboard.Results: The pill filming system completes its workflow after generating 300 pill images. The total time to collect data per pill takes 21 minutes and 25 seconds. The generated image size is 1280 × 960 pixels, the horizontal and vertical resolutions are both 96 DPI (dot per inch), and the file extension is .jpg.Conclusions: This paper proposes a system that can automatically generate pill image data from various angles. The pill observation data from various angles include many cases. In addition, the data collected in the same controlled environment have a uniform background, making it easy to process the images. Large quantities of high-quality data from the pill filming system can contribute to various studies using pill images.
- 16 July 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (3) , 446-448
Design of Automatic Isolated Medical Waste Bin Cover for Drying Waste
Background. The recent outbreak of COVID-19 has led to an increase in isolated medical waste, making the disposal of isolated medical waste a significant problem. There is the dedicated waste bin with four-sided locking-type at the top, causing contact during waste disposal. And it has infection possibility with high humidity. Purpose. In this article, we suggest automatic isolated medical waste bin cover for drying waste.
- 16 July 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (3) , 446-448
Design of Automatic Isolated Medical Waste Bin Cover for Drying Waste
Background. The recent outbreak of COVID-19 has led to an increase in isolated medical waste, making the disposal of isolated medical waste a significant problem. There is the dedicated waste bin with four-sided locking-type at the top, causing contact during waste disposal. And it has infection possibility with high humidity. Purpose. In this article, we suggest automatic isolated medical waste bin cover for drying waste.
- Open Access
- 31 July 2020
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 26 (3) , 243-247
Design of Automatic Hand Sanitizer System Compatible with Various Containers
Demand for hand sanitizers has surged since the coronavirus broke out and spread around the world. Hand sanitizers are usually applied by squirting the sanitizer liquid when one presses a pump with one’s hand. This causes many people to come into contact with the pump handle, which increases the risk of viral transmission. Some hand sanitizers on the market are automatically pumped. However, because sanitizer containers and pump devices are designed to be compatible only between products produced by the same manufacturer, consumers must also repurchase the container for the liquid if they replace the hand sanitizer. Therefore, this paper suggests the design of an automatic hand sanitizer system compatible with various sanitizer containers. An automatic hand sanitizer system was designed, which will be presented in two stages describing the instrument structure and control parts. This work focused on using the elasticity of pumps and improving people’s access to devices. We have designed an automatic hand sanitizer system that is compatible with various containers. When one moves one’s hand close to the device sensor, the hand sanitizer container is pumped once. The automatic hand sanitizer device proposed in this paper is ultimately expected to contribute to contactless hand disinfection in public places and virus infection prevention. Additionally, it is economical and eco-friendly by decreasing waste emissions.
- 31 July 2020
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 26 (3) , 243-247
Open AccessDesign of Automatic Hand Sanitizer System Compatible with Various Containers
Demand for hand sanitizers has surged since the coronavirus broke out and spread around the world. Hand sanitizers are usually applied by squirting the sanitizer liquid when one presses a pump with one’s hand. This causes many people to come into contact with the pump handle, which increases the risk of viral transmission. Some hand sanitizers on the market are automatically pumped. However, because sanitizer containers and pump devices are designed to be compatible only between products produced by the same manufacturer, consumers must also repurchase the container for the liquid if they replace the hand sanitizer. Therefore, this paper suggests the design of an automatic hand sanitizer system compatible with various sanitizer containers. An automatic hand sanitizer system was designed, which will be presented in two stages describing the instrument structure and control parts. This work focused on using the elasticity of pumps and improving people’s access to devices. We have designed an automatic hand sanitizer system that is compatible with various containers. When one moves one’s hand close to the device sensor, the hand sanitizer container is pumped once. The automatic hand sanitizer device proposed in this paper is ultimately expected to contribute to contactless hand disinfection in public places and virus infection prevention. Additionally, it is economical and eco-friendly by decreasing waste emissions.