Soyoon Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Soyoon Kwon has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kwang Gi Kim
Department of Biomedical Engineering, Gachon University, Incheon, Republic of Korea
3 shared publications - Juhui Lee
Department of Biomedical Engineering, College of Health Science, Gachon University, Incheon, Korea
2 shared publications - Dong Ah Shin
Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea
1 shared publication Gil Joon Suh
National Medical Center, Seoul 04564, Republic of Korea
1 shared publication- Jaeheung Park
Seoul National University
1 shared publication - Jaehoon Sim
Department of Intelligence and Information, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
1 shared publication
Latest Publications
- 2 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 281, 109348
Non-invasive classification of coronary perfusion pressure during CPR using smartphone-based skin video and deep learning
- 2 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 281, 109348
Non-invasive classification of coronary perfusion pressure during CPR using smartphone-based skin video and deep learning
- Open Access
- 31 January 2023
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 29 (1) , 84-88
Development of an Automatic Pill Image Data Generation System
Objectives: Since the easiest way to identify pills and obtain information about them is to distinguish them visually, many studies on image processing technology exist. However, no automatic system for generating pill image data has yet been developed. Therefore, we propose a system for automatically generating image data by taking pictures of pills from various angles. This system is referred to as the pill filming system in this paper.Methods: We designed the pill filming system to have three components: structure, controller, and a graphical user interface (GUI). This system was manufactured with black polylactic acid using a 3D printer for lightweight and easy manufacturing. The mainboard controls data storage, and the entire process is managed through the GUI. After one reciprocating movement of the seesaw, the web camera at the top shoots the target pill on the stage. This image is then saved in a specific directory on the mainboard.Results: The pill filming system completes its workflow after generating 300 pill images. The total time to collect data per pill takes 21 minutes and 25 seconds. The generated image size is 1280 × 960 pixels, the horizontal and vertical resolutions are both 96 DPI (dot per inch), and the file extension is .jpg.Conclusions: This paper proposes a system that can automatically generate pill image data from various angles. The pill observation data from various angles include many cases. In addition, the data collected in the same controlled environment have a uniform background, making it easy to process the images. Large quantities of high-quality data from the pill filming system can contribute to various studies using pill images.
- 31 January 2023
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 29 (1) , 84-88
Open AccessDevelopment of an Automatic Pill Image Data Generation System
Objectives: Since the easiest way to identify pills and obtain information about them is to distinguish them visually, many studies on image processing technology exist. However, no automatic system for generating pill image data has yet been developed. Therefore, we propose a system for automatically generating image data by taking pictures of pills from various angles. This system is referred to as the pill filming system in this paper.Methods: We designed the pill filming system to have three components: structure, controller, and a graphical user interface (GUI). This system was manufactured with black polylactic acid using a 3D printer for lightweight and easy manufacturing. The mainboard controls data storage, and the entire process is managed through the GUI. After one reciprocating movement of the seesaw, the web camera at the top shoots the target pill on the stage. This image is then saved in a specific directory on the mainboard.Results: The pill filming system completes its workflow after generating 300 pill images. The total time to collect data per pill takes 21 minutes and 25 seconds. The generated image size is 1280 × 960 pixels, the horizontal and vertical resolutions are both 96 DPI (dot per inch), and the file extension is .jpg.Conclusions: This paper proposes a system that can automatically generate pill image data from various angles. The pill observation data from various angles include many cases. In addition, the data collected in the same controlled environment have a uniform background, making it easy to process the images. Large quantities of high-quality data from the pill filming system can contribute to various studies using pill images.
- 26 March 2022
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (5) , 674-676
Design of the Optical Dual-Band Filter for Emission of Dual Fluorescein Through the Irradiation of Single Optical Source
In this study, a dual-band band-pass filter (BPF) is designed to separate the dual-wavelength emissions of 5-aminolevulinic acid (5-ALA) and fluorescence sodium (yellow dye). The dual-band BPF was investigated experimentally to improve its accuracy, speed, and energy efficiency in clinical settings. The possibility of dual fluorescence emissions with a single irradiation is proposed, which saves energy by producing 2 fluorescence diagnostic effects using a single piece of equipment.
- 26 March 2022
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (5) , 674-676
Design of the Optical Dual-Band Filter for Emission of Dual Fluorescein Through the Irradiation of Single Optical Source
In this study, a dual-band band-pass filter (BPF) is designed to separate the dual-wavelength emissions of 5-aminolevulinic acid (5-ALA) and fluorescence sodium (yellow dye). The dual-band BPF was investigated experimentally to improve its accuracy, speed, and energy efficiency in clinical settings. The possibility of dual fluorescence emissions with a single irradiation is proposed, which saves energy by producing 2 fluorescence diagnostic effects using a single piece of equipment.
- 16 July 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (3) , 446-448
Design of Automatic Isolated Medical Waste Bin Cover for Drying Waste
Background. The recent outbreak of COVID-19 has led to an increase in isolated medical waste, making the disposal of isolated medical waste a significant problem. There is the dedicated waste bin with four-sided locking-type at the top, causing contact during waste disposal. And it has infection possibility with high humidity. Purpose. In this article, we suggest automatic isolated medical waste bin cover for drying waste.
- 16 July 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (3) , 446-448
Design of Automatic Isolated Medical Waste Bin Cover for Drying Waste
Background. The recent outbreak of COVID-19 has led to an increase in isolated medical waste, making the disposal of isolated medical waste a significant problem. There is the dedicated waste bin with four-sided locking-type at the top, causing contact during waste disposal. And it has infection possibility with high humidity. Purpose. In this article, we suggest automatic isolated medical waste bin cover for drying waste.