Kiran Kumar Challa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kiran Kumar Challa has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Gurunath Gurrala
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
3 shared publicationsVenkataramana Ajjarapu
Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA
3 shared publications- Alok Kumar Bharati
Pacific Northwest National Laboratory, Richland, WA, USA
2 shared publications - Gurunath Gurrala
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
2 shared publications - Aditya Shankar Kar
Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA
1 shared publication - Amarsagar Reddy Ramapuram Matavalam
School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
1 shared publication
Latest Publications
- 17 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Exploiting the data from digital protective relays for generator model validation in power systems
- 17 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Exploiting the data from digital protective relays for generator model validation in power systems
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 2520-2532
Harnessing Flexibility of Distribution System With Uncertain Loads and DERs
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 2520-2532
Harnessing Flexibility of Distribution System With Uncertain Loads and DERs
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (1) , 82-92
T&D Interactions and Future-Grid Stability: Role of IBR-DER-Driven T&D Interactions in Future-Grid Stability
The power grid is rapidly evolving, leading to unplanned operating conditions where the distribution system is no longer a passive consumer of electric energy. Most of the bulk system stability analytics assume that the distribution system is a passive consumer of electricity, which needs to be reevaluated with the evolving power grid. Large-scale integration of inverter-based technology, like distributed generation (DG) and flexible loads [(collectively called distributed energy resources (DERs)], in the distribution system is leading to an increase in transmission and distribution (T&D) system interactions. T&D interactions can be defined as the interdependence of system planning, performance, and operational decision making between T&D systems. T&D interactions impact several power grid aspects, including system stability, system planning, protection and controls, system resilience and reliability enhancement, etc. The California Independent System Operator (CAISO) has shed some light on the operational challenges observed in the real world and has highlighted the need to develop mechanisms to utilize T&D interactions for reliable grid operation (e.g., DER-based automatic generation control). For a stable future power grid, modeling, analyzing, and utilizing these T&D interactions effectively will be crucial. Aggregated models like the composite load models (CLMs) and other reduced order models (ROMs) can capture certain aggregated behavior of distribution system aspects, but they do not capture some features, like unbalanced nature and feeder voltage impacts on the distribution loads and DERs. T&D cosimulation can effectively capture the T&D interactions and their impact on power system stability.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (1) , 82-92
T&D Interactions and Future-Grid Stability: Role of IBR-DER-Driven T&D Interactions in Future-Grid Stability
The power grid is rapidly evolving, leading to unplanned operating conditions where the distribution system is no longer a passive consumer of electric energy. Most of the bulk system stability analytics assume that the distribution system is a passive consumer of electricity, which needs to be reevaluated with the evolving power grid. Large-scale integration of inverter-based technology, like distributed generation (DG) and flexible loads [(collectively called distributed energy resources (DERs)], in the distribution system is leading to an increase in transmission and distribution (T&D) system interactions. T&D interactions can be defined as the interdependence of system planning, performance, and operational decision making between T&D systems. T&D interactions impact several power grid aspects, including system stability, system planning, protection and controls, system resilience and reliability enhancement, etc. The California Independent System Operator (CAISO) has shed some light on the operational challenges observed in the real world and has highlighted the need to develop mechanisms to utilize T&D interactions for reliable grid operation (e.g., DER-based automatic generation control). For a stable future power grid, modeling, analyzing, and utilizing these T&D interactions effectively will be crucial. Aggregated models like the composite load models (CLMs) and other reduced order models (ROMs) can capture certain aggregated behavior of distribution system aspects, but they do not capture some features, like unbalanced nature and feeder voltage impacts on the distribution loads and DERs. T&D cosimulation can effectively capture the T&D interactions and their impact on power system stability.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5187-5197
Accurate Representation of Distribution System Dynamics With DERs for Bulk System Studies
While there has beensignificant progress in recent years to incorporate the dynamics of distribution systems and industrial loads into the transmission using aggregated composite load models (CLM); there is no study that evaluates the accuracy of a well-tuned CLM model versus the true dynamics of a distribution system (DS) with 3-$\phi$, 1-$\phi$ motors, ZIP loads, and distributed energy resources (DERs) connected to a transmission system (TS). This paper aims to address this gap by analyzing the limitations of the CLM and proposing physics-based approaches to address these drawbacks. We show that a single CLM is not flexible enough to represent the aggregated DS dynamics in situations when only a few motors in the DS stall or a few DERs trip. To address the drawback of the single CLM, we propose a DS structure preserving reduced order model (DS-ROM) that clusters nodes in the DS and represents each cluster using a CLM. We then present a Python-based automated approach to determine the parameters of the DS-ROM. Results on IEEE-14-bus TS connected to IEEE-37-node DS and a practical 240-node DS demonstrate that DS-ROM can capture the DS dynamics for various kinds of TS faults with an accuracy of $\sim$98%.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5187-5197
Accurate Representation of Distribution System Dynamics With DERs for Bulk System Studies
While there has beensignificant progress in recent years to incorporate the dynamics of distribution systems and industrial loads into the transmission using aggregated composite load models (CLM); there is no study that evaluates the accuracy of a well-tuned CLM model versus the true dynamics of a distribution system (DS) with 3-$\phi$, 1-$\phi$ motors, ZIP loads, and distributed energy resources (DERs) connected to a transmission system (TS). This paper aims to address this gap by analyzing the limitations of the CLM and proposing physics-based approaches to address these drawbacks. We show that a single CLM is not flexible enough to represent the aggregated DS dynamics in situations when only a few motors in the DS stall or a few DERs trip. To address the drawback of the single CLM, we propose a DS structure preserving reduced order model (DS-ROM) that clusters nodes in the DS and represents each cluster using a CLM. We then present a Python-based automated approach to determine the parameters of the DS-ROM. Results on IEEE-14-bus TS connected to IEEE-37-node DS and a practical 240-node DS demonstrate that DS-ROM can capture the DS dynamics for various kinds of TS faults with an accuracy of $\sim$98%.
- Open Access
- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 5424-5439
Development of a Generalized Scaled-Down Realistic Substation Laboratory Model for Smart Grid Research and Education
This paper introduces a physical scaled-down realistic substation laboratory model development for translational research and education in smart grids. The development of a substation panel with four 3-$\phi $ feeders of 415 V, 65 A rating is described in detail. The developed substation model can be configured to realize seven widely used substation bus bar arrangements. A programmable logic controller (PLC) is used to create interlock mechanisms for mimicking the actual substation operation practices. Provision is made to realize the gang and independent pole operation of circuit breakers, the manual and remote modes of operation, and different types of current transformer arrangements. The substation panel can host up to 10 commercial IEDs, and multiple substation panels can be cascaded to form a bigger station using the master-slave configuration of PLCs. All the potential transformer and current transformer measurements, circuit breaker, isolator, and earth switch status signals are made available for connecting field devices. The developed substation model can be used for advanced research on substation automation using IEC61850, validation of new protection strategies, implementation and testing of new algorithms (such as topology processing, state estimation) for energy management systems (EMS) like how they get implemented in the field.- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 5424-5439
Open AccessDevelopment of a Generalized Scaled-Down Realistic Substation Laboratory Model for Smart Grid Research and Education
This paper introduces a physical scaled-down realistic substation laboratory model development for translational research and education in smart grids. The development of a substation panel with four 3-$\phi $ feeders of 415 V, 65 A rating is described in detail. The developed substation model can be configured to realize seven widely used substation bus bar arrangements. A programmable logic controller (PLC) is used to create interlock mechanisms for mimicking the actual substation operation practices. Provision is made to realize the gang and independent pole operation of circuit breakers, the manual and remote modes of operation, and different types of current transformer arrangements. The substation panel can host up to 10 commercial IEDs, and multiple substation panels can be cascaded to form a bigger station using the master-slave configuration of PLCs. All the potential transformer and current transformer measurements, circuit breaker, isolator, and earth switch status signals are made available for connecting field devices. The developed substation model can be used for advanced research on substation automation using IEC61850, validation of new protection strategies, implementation and testing of new algorithms (such as topology processing, state estimation) for energy management systems (EMS) like how they get implemented in the field. - Open Access
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 64639-64652
Development of an Experimental Scaled-Down Frequency Dependent Transmission Line Model
The penetration of power electronic based equipment in the power grid has increased the co-occurrence of electromechanical and electromagnetic transients. Significant research efforts have been focused in the last decade to study these interactions. Frequency dependent transmission line models are indispensable to understand such interactions. This paper describes a systematic procedure for the development of an experimental scaled-down 220 V frequency dependent transmission line model of a 230 kV transmission line. A reduced order lumped parameter frequency dependent transmission line using modal transformation is derived for the 230 kV transmission line and scaled-down to 220 V. Clarke and inverse Clarke transformations are implemented using specially designed 1- Φ transformers. The inductances of the scaled-down model are realized using amorphous cores. Line energization, balanced, and unbalanced fault studies are carried out using the experimental line. The experimental results are compared with the simulation results of a universal line and a constant parameter π-model using EMTP-RV. The proposed experimental line properly captured important features of the frequency dependent line such as smoother wave shape during energization, traveling time, currents, and voltage magnitudes during the fault and after the fault removal.
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 64639-64652
Open AccessDevelopment of an Experimental Scaled-Down Frequency Dependent Transmission Line Model
The penetration of power electronic based equipment in the power grid has increased the co-occurrence of electromechanical and electromagnetic transients. Significant research efforts have been focused in the last decade to study these interactions. Frequency dependent transmission line models are indispensable to understand such interactions. This paper describes a systematic procedure for the development of an experimental scaled-down 220 V frequency dependent transmission line model of a 230 kV transmission line. A reduced order lumped parameter frequency dependent transmission line using modal transformation is derived for the 230 kV transmission line and scaled-down to 220 V. Clarke and inverse Clarke transformations are implemented using specially designed 1- Φ transformers. The inductances of the scaled-down model are realized using amorphous cores. Line energization, balanced, and unbalanced fault studies are carried out using the experimental line. The experimental results are compared with the simulation results of a universal line and a constant parameter π-model using EMTP-RV. The proposed experimental line properly captured important features of the frequency dependent line such as smoother wave shape during energization, traveling time, currents, and voltage magnitudes during the fault and after the fault removal.
- Open Access
- 18 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 15 (15) , 2226-2239
An algorithm for fitting passive equivalent circuits for lumped parameter frequency dependent transmission line models
Accurately fitting rational functions to the frequency response of modal impedances is crucial for including frequency dependency in lumped parameter models of transmission lines. Vector fitting is widely used for fitting rational functions to the frequency response of modal impedances and then an R‐L equivalent circuit is obtained from the rational functions. A single‐step method based on the properties of Foster equivalent circuit is proposed to directly fit an R‐L equivalent circuit to the frequency response of modal impedances. The positive peaks, negative peaks and the positive zero crossings of the slope change plot of the frequency response are found to provide a good approximation of zeros, poles and the flat region locations of the frequency response. An enhanced fitting algorithm is proposed based on these observations. A close enough fitting is achieved using the proposed method with less number of passive elements. Using the proposed model in EMTP‐RV, 400, 765, 1200 kV transmission lines and a 11‐bus 500 kV network are simulated for switching transients. The results are compared with the constant parameter cascaded ‐model and the universal line model in EMTP‐RV. The switching transient results of the proposed model are found to be comparable to the Marti's model in EMTP‐RV.- 18 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 15 (15) , 2226-2239
Open AccessAn algorithm for fitting passive equivalent circuits for lumped parameter frequency dependent transmission line models
Accurately fitting rational functions to the frequency response of modal impedances is crucial for including frequency dependency in lumped parameter models of transmission lines. Vector fitting is widely used for fitting rational functions to the frequency response of modal impedances and then an R‐L equivalent circuit is obtained from the rational functions. A single‐step method based on the properties of Foster equivalent circuit is proposed to directly fit an R‐L equivalent circuit to the frequency response of modal impedances. The positive peaks, negative peaks and the positive zero crossings of the slope change plot of the frequency response are found to provide a good approximation of zeros, poles and the flat region locations of the frequency response. An enhanced fitting algorithm is proposed based on these observations. A close enough fitting is achieved using the proposed method with less number of passive elements. Using the proposed model in EMTP‐RV, 400, 765, 1200 kV transmission lines and a 11‐bus 500 kV network are simulated for switching transients. The results are compared with the constant parameter cascaded ‐model and the universal line model in EMTP‐RV. The switching transient results of the proposed model are found to be comparable to the Marti's model in EMTP‐RV. - 1 December 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 189
Dynamic State and Parameter Estimation of Synchronous Generator from Digital Relay Records
- 1 December 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 189
Dynamic State and Parameter Estimation of Synchronous Generator from Digital Relay Records