WLWilliam D. Lack

William D. Lack

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William D. Lack has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • AAOS Appropriate Use Criteria Summary: Treatment of Mid-Shaft Clavicle Fractures

    by William D. Lack, Omkar Baxi, Henry Bone Ellis, Barbara Krause, Jayson Murray, Kaitlyn Sevarino, Danielle M. Schulte

    The American Academy of Orthopaedic Surgeons (AAOS) has developed an Appropriate Use Criteria (AUC) for the Treatment of Mid-Shaft Clavicle Fractures. Evidence-based information, in conjunction with the clinical expertise of physicians, was used to develop criteria to determine the appropriateness of surgical and nonsurgical treatment in patients who have suffered a mid-shaft clavicle fracture. The Appropriate Use Criteria for the Treatment of Mid-Shaft Clavicle Fractures were derived by identifying clinical indications typical of patients who have suffered a mid-shaft clavicle fracture. These indications were most often variables observable by the clinician, including symptoms or results of diagnostic tests. In addition, “human factor” (eg, activity level or demographic variables) can be considered. The 96 patient scenarios and two treatments were developed by the writing panel, a group of clinicians who are specialists in this Appropriate Use Criteria topic. Next, a separate, multidisciplinary rating panel (made up of specialists and nonspecialists) rated the appropriateness of treatment for each patient scenario using a 9-point scale to designate a treatment as “Appropriate” (median rating, 7 to 9), “May Be Appropriate” (median rating, 4 to 6), or “Rarely Appropriate” (median rating, 1 to 3).

  • American Academy of Orthopaedic Surgeons Appropriate Use Criteria: Case Studies on Treatment of Mid-shaft Clavicle Fractures

    by Omkar Baxi, William D. Lack, Henry Bone Ellis

    Mid-shaft clavicle fractures in the adult and postpubescent adolescent population are a common injury treated by orthopaedic surgeons. This injury has a notable burden of disease due to its prevalence, effect on the patient, and effect on the society through cost of treatment and time lost from social activity. Determining surgical and nonsurgical care for a clavicle fracture can represent a clinical challenge. To assist clinicians with this treatment decision, the American Academy of Orthopaedic Surgeons has developed and adopted an appropriate use criteria to recommend nonsurgical and surgical treatment based on a variety of patient and injury characteristics. These criteria are available online and through phone-based applications. This article aims to illustrate how the criteria may be applied in clinical practice.

  • Open Access

    Efficacy and limitations of a web-based native adult knee septic arthritis calculator in urban trauma care

    by Ryan P. Serbin, Joseph Burger, Susan Odum, Calvin Chandler, Sarah Welch, Noah Di Napoli, Ashley Duncan, Meghan K. Wally, William Lack, Madhav Karunakar, et al.

    Background: Septic arthritis of the knee presents significant diagnostic challenges. Traditional diagnostic methods demonstrate limited sensitivity and specificity, whereas delayed intervention risks irreversible joint damage. A web-based septic arthritis calculator offers quantifiable risk assessment, but its performance requires validation. Questions/Purposes: We evaluated (1) diagnostic accuracy of a web-based septic arthritis calculator in a tertiary referral center and (2) optimal risk thresholds for recommending surgical intervention and for confidently excluding septic arthritis. Methods: We retrospectively analyzed 121 consults for suspected septic arthritis of the knee including arthrocentesis in adult patients at a tertiary referral center from 2018 to 2023. Newman criteria served as the diagnostic gold standard for septic arthritis. We calculated risk probabilities using the web-based tool incorporating 6 clinical and laboratory variables. Receiver operating characteristic analysis identified optimal thresholds for surgical intervention and assessed diagnostic performance. Results: The calculator demonstrated excellent discrimination between septic (n = 75) and nonseptic (n = 46) joints (area under the curve of 0.97 [95% confidence interval 0.95–0.99; P < .001). Median calculated probabilities for sepsis were 80% vs 4% for nonseptic cases. Optimal thresholds included 58% for recommending surgical intervention (sensitivity 89%, specificity 98%, positive predictive value 99%) and 24.6% for excluding septic arthritis (sensitivity 96%, specificity 87%, negative predictive value 93%). Both thresholds achieved 93% correct classification. Conclusions: The web-based calculator provides excellent diagnostic accuracy and clinically relevant thresholds derived from ROC analysis: ≥58% for recommending surgical intervention and <24.6% for confidently excluding septic arthritis. These findings support systematic implementation in tertiary referral centers to enhance diagnostic precision and optimize resource allocation, although prospective validation remains essential. Level of Evidence: III.

  • Open Access

    Septic Arthritis Risk Calculator: External Validation of a Prediction Model for Native Adult Knees Among Veterans

    by Kaden M. Kunz, Patrick Mark, Jacob Tadje, Duncan Skerrett, Hannah Brubeck, Alison W. Henderson, Daniel C. Norvell, William D. Lack

    Introduction: Septic arthritis presenting as an acutely inflamed knee (AIK) requires prompt diagnosis and treatment to prevent irreversible joint damage and systemic complications. A lack of high-quality diagnostic criteria hinders decision making. A multivariable prediction model developed among nonveterans demonstrated strong performance characteristics. This was converted into the Septic Arthritis Risk Calculator (SARC), providing personalized risk estimates for native knee septic arthritis. The purpose of this study was to externally validate the accuracy and calibration of SARC. Methods: A retrospective cohort study was conducted for veterans with a native AIK at a Veterans Affairs Medical Center from 2007 to 2022. Demographics, comorbidities, history, physical examination, laboratory and radiographic findings, and confirmation of septic arthritis were collected. Septic arthritis risk was calculated. Discrimination was assessed by receiver operating characteristic analysis. Calibration was assessed via Hosmer-Lemeshow goodness-of-fit and Cox calibration regression (statistical significance for P < 0.05). Results: The cohort consisted of 241 veterans with 50 cases (20.7%) of septic arthritis. The area under the curve was high (0.89) with 90% of cases correctly classified. The model fit the cohort well, supported by Hosmer-Lemeshow goodness-of-fit ( P = 0.43) and Cox calibration regression yielding an estimated slope of 1.0 (95% CI: 0.74 to 1.3) and intercept near zero (−0.51 to 0.51). Conclusion: SARC was accurate and well calibrated among veterans as in the original nonveteran cohort. We recommend its use in the setting of an AIK. Further research will involve implementation through an online decision support tool for point of care clinical use.

  • A Multicenter Study of Intertrochanteric and Pertrochanteric Fragility Fractures: Spanning Fixation Mitigates the Risk of Peri-Implant Fractures

    by Michael P. Murphy, Kaden M. Kunz, Patrick Mark, Jacob Tadje, Madeline Tiee, Bailey Johnson, Hobie Summers, Joseph Cohen, William D. Lack

    Background: Whether the fixation of pertrochanteric and intertrochanteric fragility fractures impacts the risk of subsequent peri-implant fracture remains unclear. We hypothesized that peri-implant fracture after an index pertrochanteric or intertrochanteric fragility fracture is associated with fixation that does not reach the distal metaphysis (non-spanning fixation). Methods: Retrospective chart review was performed of patients treated for index pertrochanteric and intertrochanteric femoral fragility fractures at 2 health-care systems between January 1, 2005, and January 1, 2018. Cases were categorized by whether or not fixation reached the distal metaphysis (spanning compared with non-spanning). Kaplan-Meier survival analyses estimated cumulative incidences of peri-implant fracture stratified by patient, injury, and treatment characteristics, with hazard ratios (HRs) reported when significant. We also assessed whether spanning or non-spanning fixation was associated with a contralateral femoral fracture (a proxy for patient-related fracture risk). Significance was set at p < 0.05. Results: In this study, 913 patients with a median age of 80 years had a median follow-up of 5 months (interquartile range [IQR], 3 weeks to 2.7 years). The OTA/AO classification included 388 type 31-A1 fractures, 324 type 31-A2 fractures, and 201 type 31-A3 fractures. There were 18 subsequent peri-implant fractures (1.9%) and 40 subsequent contralateral femoral fractures (4.4%). The cumulative incidence of peri-implant fracture was lower over time (p < 0.01) with spanning fixation (0% prior to 1 year) compared with non-spanning (3.3% prior to 1 year). The HR of spanning fixation for the entire time period was 0.14 (95% confidence interval, 0.03 to 0.62; p < 0.01). Peri-implant fracture risk was greater with non-spanning plates (p < 0.01) and non-spanning nails (p < 0.01) than spanning fixation, with cumulative 1-year incidences of 3.5% for non-spanning plates, 2.6% for non-spanning nails, and 0% for spanning fixation. Peri-implant fracture was not associated with other variables (p > 0.05). Contralateral fracture was not associated with the fixation group (p = 0.77), tempering concern regarding potential bias. Conclusions: Spanning fixation following pertrochanteric and intertrochanteric femoral fragility fractures mitigates the risk of a peri-implant fracture. However, the choice of fixation for a given patient requires that this risk be considered within the greater context of surgical decision-making. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


  • Development of an Exosuit Knee Brace for Anterior Cruciate Ligament Injury

    by Jing-Sheng Li, Elaine Lowinger, Morgan E. Leslie, Geoffrey S. Balkman, Roy Kornbluh, William D. Lack, Patrick M. Aubin, Thomas Libby

    The anterior cruciate ligament (ACL) is a crucial passive stabilizer of the knee joint. ACL injuries affect the anteroposterior stability of the knee joint. Many rigid knee braces with hinge designs claim to provide stabilization forces for the knee, however, current clinical practice guidelines recommend not using a functional knee brace during return to activity and return to play phases. In this study, we aimed to design a hinge-less exosuit knee brace that combines flexible materials to improve comfort at the brace-body interface while providing dynamic support forces during walking tasks using an offboard actuation system. We recruited 11 participants: 5 for design tests and 6 for walking tests. Our active exosuit knee brace was able to produce up to 88.9 N of cable force during a portion of the stance phase with a rise time of 111-150 milliseconds at different load settings and under 10N during the swing phase. Comfort scores were high (> 7) during most walking tests. The range of knee flexion was reduced by about 5 degrees when the exosuit knee brace was activated during walking, and brace migration was within 10 mm in most cases.

  • Open Access

    Assessing Supraspinatus Tendon Elasticity at Different Locations and Loading Conditions Using Ultrasound Shear-Wave Elastography in Young Healthy Population

    by Arash Azhideh, Peyman Mirghaderi, Sara Haseli, William D. Lack, Karen C. Takatani, Liisa C. Hammer, Kevin F. Malik, Hannah Tifft, Kyle Griffith, Majid Chalian

    Objective: This prospective study aims to investigate the feasibility of Shear-Wave Elastography (SWE) for assessing the mechanical properties of the normal supraspinatus tendon and describing the elastographic features of the supraspinatus tendon under different loading conditions and positions. Methods: Twenty healthy volunteers (10 males and 10 females, aged 18–25 years) were examined by SWE using an 18-4 MHz linear array transducer. The elasticity of the supraspinatus tendon of the dominant hand was measured at three distinct locations: the insertion, middle, and myotendinous junction of the tendon. These measurements were taken under various conditions, including non-loading and the application of 5, 10, and 20 lb forces at five different positions. Results: The average elasticity was 69.2 ± 26.5 kilopascals across all positions and forces, with the middle part of the tendon exhibiting the highest elasticity (72.6 ± 6.2 kPa). An ascending trend in elasticity was observed by increasing the applied load, and the highest elasticity was observed with a 20 lb load. Determining the normal elasticity of the tendon is an important clinical implication, as understanding what is normal is essential for identifying pathological conditions. Conclusions: SWE is a feasible and promising technology for the collection of data on how the supraspinatus tendon behaves under loading conditions. There is a need for further study to better understand tendon response to activity and resultant injuries.

  • Geriatric femur fractures: Index fracture pattern is associated with the risk of subsequent peri-implant fracture

    by Michael P. Murphy, Madeline S. Tiee, Bailey E. Johnson, Hobie D. Summers, Joseph B. Cohen, William D. Lack


  • Sagittal Angulation and the Treatment of Geriatric Femoral Neck Fractures: Time to Update our Classification Systems

    by Duncan Ba Skerrett, Lara Shefelbine, Max Coale, Florence Unno, William Lack

    OBJECTIVES: Inconsistent outcomes have been reported for percutaneous fixation of Garden I/II femoral neck fractures in geriatric patients. It was hypothesized that accounting for variable follow-up would better estimate the failure rate of percutaneous fixation with and without significant sagittal angulation. METHODS: Design: Retrospective. Setting: Single academic healthcare system. Patient Selection Criteria: Patients ≥50 years of age treated with percutaneous screw fixation of Garden I/II (OTA/AO B1.1/B1.2) femoral neck fractures from 2010 to 2020 were identified. Pathologic fractures and open approaches were excluded. Outcome Measures and Comparisons: Sagittal angulation was measured using a previously described method. 11 Treatment failure was defined as early fixation failure (within 6 weeks), nonunion, and/or avascular necrosis. Potential associations between treatment failure and patient, injury, and treatment variables were assessed. Cox proportional hazard analysis accounted for variable follow-up when assessing for event-free survival. RESULTS: Of the 240 fractures that met inclusion criteria, there were 20 treatment failures (8%) and 33 fractures with sagittal angulation ≥20 degrees on lateral radiographs (14%). Failure-free survival at 2 years was 91% for patients with P < 0.0001). The hazard ratio, which incorporates variable follow-up, for failure with ≥20 degrees of posterior angulation was 6.36 (P < 0.0001). No other factors were associated with treatment failure. CONCLUSIONS: Significant posterior angulation (≥20 degrees) of Garden I/II femoral neck fractures is associated with a high failure rate after screw fixation. The authors suggest characterizing fractures with ≥20 degrees of sagittal angulation as Garden III fractures to better support surgical decision making. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.