Tongzhi Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tongzhi Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Weixing Yuan
School of Aeronautical Science and Engineering, Beihang University, Beijing 100191, China
4 shared publications - Kexian Ren
Aeronautic Institute of Xiangyang, Xiangyang 441000, China
3 shared publications - Leixin Wang
School of Aeronautical Science and Engineering, Beihang University, Beijing 100191, China
3 shared publications - Hao Cheng
School of Aeronautical Science and Engineering, Beihang University, Beijing 100191, China
2 shared publications - Yifan Zhao
School of Aeronautical Science and Engineering, Beihang University, Beijing 100191, China
2 shared publications Bo Yang
School of Aeronautics Science and Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 23 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2386
Experimental Study of a Novel Prototype of Dual-Cycle Two-Phase Cooling System for a Data Cabinet
As Information Technology continues to rapidly evolve, the scale and energy consumption of data centers have seen a significant surge. Traditional air-cooling systems in data centers are notably energy intensive. This study proposes an innovative dual-cycle two-phase cooling system (DTCS) for retrofitting existing server cabinets. The system integrates the two synergistic subsystems of a pump-driven chip-level two-phase cooling system (PCTCS) and a pump-driven backplane-level two-phase cooling system (PBTCS). The PCTCS provides year-round natural cooling of high-power chips, and experimental results indicate that even under extreme outdoor conditions of up to 42 °C, the PCTCS can maintain the chip temperature at 76 °C. At the same time, the PBTCS effectively cools all components in the cabinet except the high-power chips. By efficiently controlling the chip temperature through the PCTCS, the novel DTCS ensures stable operation at data room temperatures up to 33 °C, thereby significantly reducing the energy consumption of the cooling system. The average annual pPUE of the cooling system is 1.078 at the test site in Xiangyang, Hubei province in China. The DTCS could perform well across various Chinese cities even under severe hot and moist conditions, with the average annual pPUE consistently below 1.1.
- 23 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2386
Open AccessExperimental Study of a Novel Prototype of Dual-Cycle Two-Phase Cooling System for a Data Cabinet
As Information Technology continues to rapidly evolve, the scale and energy consumption of data centers have seen a significant surge. Traditional air-cooling systems in data centers are notably energy intensive. This study proposes an innovative dual-cycle two-phase cooling system (DTCS) for retrofitting existing server cabinets. The system integrates the two synergistic subsystems of a pump-driven chip-level two-phase cooling system (PCTCS) and a pump-driven backplane-level two-phase cooling system (PBTCS). The PCTCS provides year-round natural cooling of high-power chips, and experimental results indicate that even under extreme outdoor conditions of up to 42 °C, the PCTCS can maintain the chip temperature at 76 °C. At the same time, the PBTCS effectively cools all components in the cabinet except the high-power chips. By efficiently controlling the chip temperature through the PCTCS, the novel DTCS ensures stable operation at data room temperatures up to 33 °C, thereby significantly reducing the energy consumption of the cooling system. The average annual pPUE of the cooling system is 1.078 at the test site in Xiangyang, Hubei province in China. The DTCS could perform well across various Chinese cities even under severe hot and moist conditions, with the average annual pPUE consistently below 1.1.
- Open Access
Influence of Non-Uniform Airflow on Two-Phase Parallel-Flow Heat Exchanger in Data Cabinet Cooling System
The energy consumption of data center cooling systems is rapidly increasing, necessitating urgent improvements in cooling system performance. This study investigates a pump-driven two-phase cooling system (PTCS) utilizing a parallel-flow heat exchanger (PFHE) as an evaporator, positioned at the rear of server cabinets. The findings indicate that enhancing the vapor quality at the PFHE outlet improves the overall cooling performance. However, airflow non-uniformity induces premature localized overheating, restricting further increases in vapor quality. For PFHEs operating with a two-phase outlet condition, inlet air temperature non-uniformity has a relatively minor impact on the cooling capacity but significantly affects the drop in pressure. Specifically, higher upstream air temperatures increase the pressure drop by 7%, whereas higher downstream air temperatures reduce it by 7.7%. The implementation of multi-pass configurations effectively mitigates localized overheating caused by airflow non-uniformity, suppresses the decline in cooling capacity, and enhances the operational vapor quality of the cooling system.
Open AccessInfluence of Non-Uniform Airflow on Two-Phase Parallel-Flow Heat Exchanger in Data Cabinet Cooling System
The energy consumption of data center cooling systems is rapidly increasing, necessitating urgent improvements in cooling system performance. This study investigates a pump-driven two-phase cooling system (PTCS) utilizing a parallel-flow heat exchanger (PFHE) as an evaporator, positioned at the rear of server cabinets. The findings indicate that enhancing the vapor quality at the PFHE outlet improves the overall cooling performance. However, airflow non-uniformity induces premature localized overheating, restricting further increases in vapor quality. For PFHEs operating with a two-phase outlet condition, inlet air temperature non-uniformity has a relatively minor impact on the cooling capacity but significantly affects the drop in pressure. Specifically, higher upstream air temperatures increase the pressure drop by 7%, whereas higher downstream air temperatures reduce it by 7.7%. The implementation of multi-pass configurations effectively mitigates localized overheating caused by airflow non-uniformity, suppresses the decline in cooling capacity, and enhances the operational vapor quality of the cooling system.
- Open Access
- 24 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7472
Modeling and Performance Analysis of a Pump-Driven Chip-Level Two-Phase Cooling System in Data Centers
As a powerful solution for heat dissipation in data centers, chip-level cooling continues to capture escalating attention in research and application domains. To accurately analyze system performance, identify potential avenues for system optimization, and inform future practical applications, we developed a steady-state, one-dimensional mathematical model for a novel pump-driven chip-level two-phase cooling system (PCTCS). This model was constructed based on our previous study and was confirmed against existing experimental data. Our simulations scrutinized PCTCS performance under default conditions and investigated the effects of key parameters, such as refrigerant type, condenser vertical positioning, and cooling water temperature. Results showed that the system could manage an 80 W power output from each CPU while maintaining CPU temperatures around 79 °C at a cooling water temperature of 45 °C. We discovered the choice of refrigerant had a significant impact on performance, with R32 outperforming R134a and R113. While the vertical position of the condenser influenced the PCTCS’s internal parameters, its overall impact on system performance was negligible. Moreover, provided the chip temperature remained within a safe range, our study found that increasing the cooling water temperature improved the energy efficiency ratio of the refrigerant pump and reduced the temperature difference between the chips and the cold source.
- 24 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7472
Open AccessModeling and Performance Analysis of a Pump-Driven Chip-Level Two-Phase Cooling System in Data Centers
As a powerful solution for heat dissipation in data centers, chip-level cooling continues to capture escalating attention in research and application domains. To accurately analyze system performance, identify potential avenues for system optimization, and inform future practical applications, we developed a steady-state, one-dimensional mathematical model for a novel pump-driven chip-level two-phase cooling system (PCTCS). This model was constructed based on our previous study and was confirmed against existing experimental data. Our simulations scrutinized PCTCS performance under default conditions and investigated the effects of key parameters, such as refrigerant type, condenser vertical positioning, and cooling water temperature. Results showed that the system could manage an 80 W power output from each CPU while maintaining CPU temperatures around 79 °C at a cooling water temperature of 45 °C. We discovered the choice of refrigerant had a significant impact on performance, with R32 outperforming R134a and R113. While the vertical position of the condenser influenced the PCTCS’s internal parameters, its overall impact on system performance was negligible. Moreover, provided the chip temperature remained within a safe range, our study found that increasing the cooling water temperature improved the energy efficiency ratio of the refrigerant pump and reduced the temperature difference between the chips and the cold source.
- 18 September 2020
- Published by Wiley in Journal of Heat Transfer
- Vol. 142 (12)
Flow Boiling in a Parallel Strip Fin Heat Sink With Nonuniform Heat Flux Conditions
This study investigates the thermal performance of a parallel strip fin heat sink (PSFHS) under various heat flux conditions at a flowrate of 100 ml/min, including uniform heat flux and nonuniform heat flux. The heat sink consists of 150 fins with a width of 1 mm, a height of 5.5 mm, and a pitch of 1 mm and has a Z-type inlet/outlet arrangement. Nine separate heaters offer thermal load to the heat sink in order to provide a uniform or nonuniform heat flux. The flow boiling process is captured by a high-speed camera. The temperatures of the heaters have been measured under the uniform and nonuniform heat flux conditions. In addition, the pressure drops inside the heat sink are also obtained. A minichannel heat sink (MCHS) with the same channel dimensions and inlet/outlet configuration is tested too. A comparison between MCHS and PSFHS is discussed in detail, which helps to understand the flow boiling characteristic in PSFHS.
- 18 September 2020
- Published by Wiley in Journal of Heat Transfer
- Vol. 142 (12)
Flow Boiling in a Parallel Strip Fin Heat Sink With Nonuniform Heat Flux Conditions
This study investigates the thermal performance of a parallel strip fin heat sink (PSFHS) under various heat flux conditions at a flowrate of 100 ml/min, including uniform heat flux and nonuniform heat flux. The heat sink consists of 150 fins with a width of 1 mm, a height of 5.5 mm, and a pitch of 1 mm and has a Z-type inlet/outlet arrangement. Nine separate heaters offer thermal load to the heat sink in order to provide a uniform or nonuniform heat flux. The flow boiling process is captured by a high-speed camera. The temperatures of the heaters have been measured under the uniform and nonuniform heat flux conditions. In addition, the pressure drops inside the heat sink are also obtained. A minichannel heat sink (MCHS) with the same channel dimensions and inlet/outlet configuration is tested too. A comparison between MCHS and PSFHS is discussed in detail, which helps to understand the flow boiling characteristic in PSFHS.