    An Ultra-Sensitive Modular Hybrid EMG–FMG Sensor with Floating Electrodes

    by Ang Ke, Jian Huang, Luyao Chen, Zhaolong Gao, Jiping He

    To improve the reliability and safety of myoelectric prosthetic control, many researchers tend to use multi-modal signals. The combination of electromyography (EMG) and forcemyography (FMG) has been proved to be a practical choice. However, an integrative and compact design of this hybrid sensor is lacking. This paper presents a novel modular EMG–FMG sensor; the sensing module has a novel design that consists of floating electrodes, which act as the sensing probe of both the EMG and FMG. This design improves the integration of the sensor. The whole system contains one data acquisition unit and eight identical sensor modules. Experiments were conducted to evaluate the performance of the sensor system. The results show that the EMG and FMG signals have good consistency under standard conditions; the FMG signal shows a better and more robust performance than the EMG. The average accuracy is 99.07% while using both the EMG and FMG signals for recognition of six hand gestures under standard conditions. Even with two layers of gauze isolated between the sensor and the skin, the average accuracy reaches 90.9% while using only the EMG signal; if we use both the EMG and FMG signals for classification, the average accuracy is 99.42%.


  • A multi-channels axon-stretch device for mechanical stress study

    by G.H. Li, S.C. Liu, A.. Ke, X.F. Zhang, J. Chen, J.P. He, S.R. Wang

    To mimic the nature stretch of axon, we developed a multiple channel device which can apply mechanical stretch to the neural axon. This device with four cell culture chambers and adjustable speed, which could be used to screening the stretch speed parameters and the potential nutrition factors that could be used to facilitate the regeneration of neuron fibers in vitro. The current design can range from 0.25um (min) to 50um (max) for each step, which covers the physiological and pathological stretch speed. The increased samples and the stepping ranges allow sophisticated experiments could be performed with this new device. The system compositions including structures and each module function are introduced in detail and the performance of this device is tested. The test of cell viability of this culture chamber show that the neuron cell and Schwann cells (SC) sustain normal morphology and cell viability. Axons stimulated by the mechanical stretch for 5 days at the speed of 1mm/day was tested by this system. The results showed that axon growth was promoted by mechanically stretch. The multi-channel axon-stretch device has been approved to be functionally in to culture neurons and stretch axons in one direction.

  • An Underactuated Prosthetic Hand with Coupled Metacarpophalangeal Joints

    by Ang Ke, Jian Huang, Jiping He

    The design of a comfortable and functional prosthetic hand is still a challenge. This paper presents the design of a tendon-driven, 3D-printed, underactuated prosthetic hand. An improved structural design was developed to make the hand more flexible. Three fingers are equipped with abduction freedom at the metacarpophalangeal joints (MCP) to ensure natural enveloping for both cylinder and sphere-like objects. A force-sensing resistor (FSR) is adopted to measure the fingertip force of each finger. Experiments show that this type of structure design provides the hand with excellent dexterity, as the added abduction ensures natural enveloping grasp gestures for both cylinder and sphere-like objects. Moreover, a myoelectric control paradigm is implemented in the control system to demonstrate the feasibility.