To improve the reliability and safety of myoelectric prosthetic control, many researchers tend to use multi-modal signals. The combination of electromyography (EMG) and forcemyography (FMG) has been proved to be a practical choice. However, an integrative and compact design of this hybrid sensor is lacking. This paper presents a novel modular EMG–FMG sensor; the sensing module has a novel design that consists of floating electrodes, which act as the sensing probe of both the EMG and FMG. This design improves the integration of the sensor. The whole system contains one data acquisition unit and eight identical sensor modules. Experiments were conducted to evaluate the performance of the sensor system. The results show that the EMG and FMG signals have good consistency under standard conditions; the FMG signal shows a better and more robust performance than the EMG. The average accuracy is 99.07% while using both the EMG and FMG signals for recognition of six hand gestures under standard conditions. Even with two layers of gauze isolated between the sensor and the skin, the average accuracy reaches 90.9% while using only the EMG signal; if we use both the EMG and FMG signals for classification, the average accuracy is 99.42%.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (2019kfyRCPY, 2019kfyXKJC019)
- National Natural Science Foundation of China (61233015, 61473130)
- Research Fund of PLA of China (BWS17J024)
This publication has 30 references indexed in Scilit:
- Underlying Physics of Conductive Polymer Composites and Force Sensing Resistors (FSRs) under Static Loading ConditionsSensors, 2017
- A Wrist-Worn Piezoelectric Sensor Array for Gesture InputJournal of Medical and Biological Engineering, 2017
- Multi-modal myocontrol: Testing combined force- and electromyography2017
- Assessment of a Wearable Force- and Electromyography Device and Comparison of the Related Signals for MyocontrolFrontiers in Neurorobotics, 2016
- First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic handJournal of Neuroscience Methods, 2015
- Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature reviewJournal of Rehabilitation Research and Development, 2015
- Problems in Assessment of Novel Biopotential Front-End with Dry Electrode: A Brief ReviewMachines, 2014
- The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and ChallengesIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- Determining the Optimal Window Length for Pattern Recognition-Based Myoelectric Control: Balancing the Competing Effects of Classification Error and Controller DelayIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2010
- A biomimetic controller for a multifinger prosthesisIEEE Transactions on Rehabilitation Engineering, 1999