JDJasen Devasagayam

Jasen Devasagayam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jasen Devasagayam has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Christopher M. Collier

    Collier Research Group, School of Engineering, The University of British Columbia, Kelowna, BC, Canada

    4 shared publications
  • Rick Bosma

    School of Engineering University of British Columbia Kelowna BC Canada

    3 shared publications
  • Ashutosh Singh

    Applied Optics and Microsystems Laboratory, University of Guelph, Guelph, ON, N1G 2W1, Canada

    1 shared publication
  • C. Harrison Brodie

    Applied Optics and Microsystems Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada

    1 shared publication
  • Iasmin de França Albuquerque

    School of Engineering College of Engineering and Physical Sciences University of Guelph Guelph ON Canada

    1 shared publication
  • Rahul Eswar

    School of Engineering College of Engineering and Physical Sciences University of Guelph Guelph ON Canada

    1 shared publication

Latest Publications

  • A velocity program using the Kanade–Lucas–Tomasi feature‐tracking algorithm with demonstration for pressure and electroosmosis conditions

    by Jasen Devasagayam, Rick Bosma, Christopher M. Collier

    Investigating microfluidic flow profiles is of interest in the microfluidics field for the determination of various characteristics of a lab-on-a-chip system. Microparticle tracking velocimetry uses computational methods upon recording video footage of microfluidic flow to ultimately visualize motion within a microfluidic system across all frames of a video. Current methods are computationally expensive or require extensive instrumentation. A computational method suited to microparticle tracking applications is the robust Kanade–Lucas–Tomasi (KLT) feature-tracking algorithm. This work explores a microparticle tracking velocimetry program using the KLT feature-tracking algorithm. The developed program is demonstrated using pressure-driven and electroosmotic flow and compared with the respective mathematical fluid flow models. An electrostatics analysis of electroosmotic flow conditions is performed in the development of the mathematical using a Poisson's Equation solver. This analysis is used to quantify the zeta potential of the electroosmotic system. Overall, the KLT feature-tracking algorithm presented in this work proved to be highly reliable and computationally efficient for investigations of pressure-driven and electroosmotic flow in a microfluidic system. This article is protected by copyright. All rights reserved


  • Voltage control for microchip capillary electrophoresis analyses

    by Rick Bosma, Jasen Devasagayam, Rahul Eswar, Iasmin de França Albuquerque, Christopher M. Collier

    This paper presents an inexpensive and easy‐to‐implement voltage sequencer instrument for use in microchip capillary electrophoresis (MCE) actuation. The voltage sequencer instrument takes a 0 – 5 V input signal from a microcontroller and produces a reciprocally proportional voltage signal with the capability to achieve the voltages required for MCE actuation. The unit developed in this work features four independent voltage channels, measures 105 × 143 × 45 mm (width × length × height), and the cost to assemble is under 60 USD. The system is controlled by a peripheral interface controller and commands are given via universal serial bus connection to a personal computer running a command line graphical user interface. The performance of the voltage sequencer is demonstrated by its integration with a fluorescence spectroscopy MCE sensor using pinched sample injection and electrophoretic separation to detect ciprofloxacin in samples of milk. This application is chosen as it is particularly important for the dairy industry, where fines and health concerns are associated with the shipping of antibiotic‐contaminated milk. The voltage sequencer instrument presented represents an effective low‐cost instrumentation method for conducting MCE, thereby making these experiments accessible and affordable for use in industries such as the dairy industry. This article is protected by copyright. All rights reserved


  • Open Access

    Microchip capillary electrophoresis dairy device using fluorescence spectroscopy for detection of ciprofloxacin in milk samples

    by Rick Bosma, Jasen Devasagayam, Ashutosh Singh, Christopher M. Collier

    Detecting antibiotics in the milk supply chain is crucial to protect humans from allergic reactions, as well as preventing the build-up of antibiotic resistance. The dairy industry has controls in place at processing facilities, but controls on dairy farms are limited to manual devices. Errors in the use of these manual devices can result in severe financial harm to the farms. This illustrates an urgent need for automated methods of detecting antibiotics on a dairy farm, to prevent the shipment of milk containing antibiotics. This work introduces the microchip capillary electrophoresis dairy device, a low-cost system that utilizes microchip capillary electrophoresis as well as fluorescence spectroscopy for the detection of ciprofloxacin contained in milk. The microchip capillary electrophoresis dairy device is operated under antibiotic-absent conditions, with ciprofloxacin not present in a milk sample, and antibiotic-present conditions, with ciprofloxacin present in a milk sample. The response curve for the microchip capillary electrophoresis dairy device is found through experimental operation with varied concentrations of ciprofloxacin. The sensitivity and limit of detection are quantified for the microchip capillary electrophoresis dairy device.


  • A Hyperspectral Imaging Instrumentation Architecture Based on Accessible Optical Disc Technology and Frequency-Domain Analyses

    by C. Harrison Brodie, Jasen Devasagayam, Christopher M. Collier

    Hyperspectral imaging (HSI) is an emergent instrumentation technology with great potential in many applications, due to its ability to measure important spectral features. However, the widespread adoption of HSI requires the development of accessible (i.e., inexpensive and uncomplicated) HSI instrumentation architectures. In this paper, we present, design, develop, and evaluate an accessible HSI instrumentation architecture, with snapshot operation, based on the integration of readily available components and frequency multiplexing with Fourier analyses. In the experimental work, an incident image beam is divided into spatial image channels, each with an assigned dynamic binary code via a dynamic coded aperture. This dynamic coded aperture is constructed from repurposed diffractive optical disc technologies and is patterned with strategic opaque and transparent regions. When it is rotated by a motor, dynamic binary codes are used, along with Fourier analyses, to identify the diffraction of each spatial image channel. The spatially overlapped spectra from the diffraction are directed onto a charge-coupled device sensor, and each spatial image channel is distinguished through Fourier analyses. The resulting Fourier amplitude spectra are transformed into corresponding functions of wavelength, and this transformation is based on the experimental instrumentation geometry. The performance of the HSI instrumentation architecture is evaluated using a comparison with data from a commercial spectrometer. The presented HSI instrumentation architecture can be adapted for 2-D operation. Ultimately, the presented HSI instrumentation architecture can benefit regions of the world that have limited financial resources and a need for accessible HSI technologies.