MMMohd Asha’aRi Masrom

Mohd Asha’aRi Masrom

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohd Asha’aRi Masrom has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Finite Element Study: Rocking Wall-Floor Connection of Precast Concrete Load-Bearing Structures Subjected to Quasi-Static Lateral Loading

    by Mohd Asha’aRi Masrom, Nor Hayati Abdul Hamid

    This paper proposes a novel semi-rigid rocking wall-floor connection. To study its seismic behavior, a preliminary study using finite element modeling (FEM) has been conducted to perceive the rocking wall response towards the precast plank before conducting a physical experimental testing in the laboratory. The finite element model was developed to investigate the lateral quasi-static-load response of the isolated rocking wall system. Subsequently, the rocking wall model was further extended by incorporating a precast concrete plank using the proposed connection. The finite element model of the rocking wall showed a good correlation with the analytical model. Furthermore, the study showed that a semi-rigid connection would result in an overstrength that should be considered when designing the rocking wall.


  • Open Access

    Review on the rocking wall systems as a self-centering mechanism and its interaction with floor diaphragm in precast concrete structures

    by Mohd Asha’aRi Masrom, Nor Hayati Abdul Hamid

    The severe damage of precast concrete wall structures that have been recorded in the past earthquake has led to the innovation of the rocking wall concept which can demonstrate free or minimum damage aftershock of an earthquake. Furthermore, extensive research works have been well conducted in the past three decades on the establishment of precast rocking wall systems, designs, details, and techniques. Despite this extensive development, little attention has been devoted to investigate the interaction between the rocking wall systems and the flooring diaphragm. The historical perspective on the development of rocking wall systems over the past few decades in the precast concrete structures is presented. Subsequently, the limited research works on the interaction of precast rocking wall to the floor diaphragm are described. Apart from that, this paper attempts to highlight the application of rocking wall systems in the context of precast connection for the precast load-bearing structures. In this contribution, the precast rocking wall-floor connection for precast load-bearing structures is proposed and presented in this paper.


  • Comparative study of bridge traffic loadings between British standards and Eurocodes

    by M. A. Masrom, L. D. Goh

    The Commission of the European Community decided to eliminate technical obstacles to provide a more open marketplace due to different design codes across countries in Europe. The good intention had caused the British Standards (BS) adopted since year 1990 in many countries to be replaced by the Eurocodes (EC) in year 2010. The withdrawal of the BS has induces a challenge to Malaysia’s practitioners in handling the bridge design in accordance to the EC. Hence, this study provides a detail discussion on the essential of traffic loads in both design codes of BS and EC. The discussion includes a new concept in EC whereby the variable actions are categorised into four representative values which are explicated in this study. The differences in the application of partial safety factor in both codes are also presented in this study. A simply supported bridge is employed in this study as a demonstration for a comparative study to highlight the difference in the implementation between the two approaches. The grillage analysis is utilised to model the seven different span lengths of bridge using the STAAD.Pro. From result, it is found that the nature of UDL governs for the maximum moment differently depending on the loaded bridge length. The modified adjustment factor also provides a significant effect to the analysis.

  • Open Access

    Seismic performance on stiffness and hysteresis loop of interior wall-slab joint for tunnel form building designs to British standard

    by M.A. Masrom, H.M. Yee, M.E. Mohamed, N.H.A. Hamid

    Seismic performance on stiffness and hysteresis loop of interior wall-slab joint for tunnel form building designs to British standard


  • Experimental study on lateral strength of wall-slab joint subjected to lateral cyclic load

    by Mohd Asha’ari Masrom, Mohd Elfie Mohamad, Nor Hayati Abdul Hamid, Amer Yusuff

    Tunnel form building has been utilised in building construction since 1960 in Malaysia. This method of construction has been applied extensively in the construction of high rise residential house (multistory building) such as condominium and apartment. Most of the tunnel form buildings have been designed according to British standard (BS) whereby there is no provision for seismic loading. The high-rise tunnel form buildings are vulnerable to seismic loading. The connections between slab and shear walls in the tunnel-form building constitute an essential link in the lateral load resisting mechanism. Malaysia is undergoing a shifting process from BS code to Eurocode (EC) for building construction since the country has realised the safety threats of earthquake. Hence, this study is intended to compare the performance of the interior wall slab joint for a tunnel form structure designed based on Euro and British codes. The experiment included a full scale test of the wall slab joint sub-assemblages under reversible lateral cyclic loading. Two sub-assemblage specimens of the wall slab joint were designed and constructed based on both codes. Each specimen was tested using lateral displacement control (drift control). The specimen designed by using Eurocode was found could survive up to 3.0% drift while BS specimen could last to 1.5% drift. The analysis results indicated that the BS specimen was governed by brittle failure modes with Ductility Class Low (DCL) while the EC specimen behaved in a ductile manner with Ductility Class Medium (DCM). The low ductility recorded in BS specimen was resulted from insufficient reinforcement provided in the BS code specimen. Consequently, the BS specimen could not absorb energy efficiently (low energy dissipation) and further sustain under inelastic deformation.