Nor Hayati Abdul Hamid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nor Hayati Abdul Hamid has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Asha’aRi Masrom
Center for Civil Engineering Studies, Universiti Teknologi MARA, Cawangan Pulau Pinang, Permatang Pauh Campus, 13500 Penang, Malaysia
2 shared publications - Rohana Hassan
School of Civil Engineering, Universiti Teknologi MARA, 40450 UiTM Shah Alam, Selangor, Malaysia
2 shared publications - Abd Ghani Kay Dora
Faculty of Civil Engineering, Universiti Teknologi MARA, 13500, Permatang Pauh, Pulau Pinang, Malaysia
1 shared publication - Aidah Jumahat
Universiti Teknologi MARA
1 shared publication Aidan Newman
Universiti Teknologi MARA (UiTM) Shah Alam
1 shared publication- Ali Awaludin
Universitas Gadjah Mada
1 shared publication
Latest Publications
- Open Access
European Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure
Many real-scale fire tests have been performed on timber connections to analyze the mechanical behavior of timber connections in previous years. However, little research focused on the bending performance of glued laminated (glulam) timber beam bolted connections after fire exposure. In this paper, the three-dimensional numerical model of the glulam timber beam bolted connections was developed and validated by experimental results. The model can simulate temperature evolution in the connections and their mechanical behavior. In the real-scale test, three (3) samples were prepared for a four-point bending test at normal temperature, while another three (3) samples were tested after exposure to a 30-min standard fire and cooled down to normal temperature. The results show the reduction of the load-carrying capacity before and after exposure to the standard fire by 23.9 kN (71.8%), 8.3 kN (26.1%), and 20.2 kN (47.6%) for bolt diameters of 12 mm, 16 mm, and 20 mm, respectively. The numerical model aims to conduct a parametric study and propose the modification of the exponential decay constant, k, for tropical glulam timber to predict the load-carrying capacity of the glulam timber beam bolted connections after exposure to standard fire.
Open AccessEuropean Yield Model Exponential Decay Constant Modification for Glulam after Fire Exposure
Many real-scale fire tests have been performed on timber connections to analyze the mechanical behavior of timber connections in previous years. However, little research focused on the bending performance of glued laminated (glulam) timber beam bolted connections after fire exposure. In this paper, the three-dimensional numerical model of the glulam timber beam bolted connections was developed and validated by experimental results. The model can simulate temperature evolution in the connections and their mechanical behavior. In the real-scale test, three (3) samples were prepared for a four-point bending test at normal temperature, while another three (3) samples were tested after exposure to a 30-min standard fire and cooled down to normal temperature. The results show the reduction of the load-carrying capacity before and after exposure to the standard fire by 23.9 kN (71.8%), 8.3 kN (26.1%), and 20.2 kN (47.6%) for bolt diameters of 12 mm, 16 mm, and 20 mm, respectively. The numerical model aims to conduct a parametric study and propose the modification of the exponential decay constant, k, for tropical glulam timber to predict the load-carrying capacity of the glulam timber beam bolted connections after exposure to standard fire.
- 25 November 2022
- Published by Springer Nature
- p. 153-160
Workability and Performance of High-Performance Concrete by Using Palm Oil Fuel Ash as a Cement Replacement Material
- 25 November 2022
- Published by Springer Nature
- p. 153-160
Workability and Performance of High-Performance Concrete by Using Palm Oil Fuel Ash as a Cement Replacement Material
- Open Access
- 14 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9194
Seismic Microzonation Map for a Fixed-Jacket Platform in the Malay Basin
The existence of soft soil in offshore areas may lead to the amplification of vibration received from offshore facilities, especially from the existing fixed-jacket platforms, which were designed without provision to seismicity, as in Malaysian water. Therefore, this study was designed to develop a seismic microzonation map and a soil amplification factor map according to soil type; we propose horizontal response spectra and site coefficient values (Ca and Cv) for the Malay Basin. A one-dimensional nonlinear analysis of layered soil (NERA) was used in the ground response analysis for six selected seismic events under five return periods of 100, 200, 500, 1000, and 2500 years. Soil amplification factors for soil types D and E showed a decreasing trend from 100 years to 2500 years. Two designed horizontal response spectra are proposed (for soil type D and E) under average and envelope conditions; a comparison with ISO showed that the proposed spectra were higher, especially for soil type E. To summarize, the seismicity effect should be included in the development of offshore industries as findings indicated that soil amplification occurred in soil types D and E at the Malay Basin.
- 14 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9194
Open AccessSeismic Microzonation Map for a Fixed-Jacket Platform in the Malay Basin
The existence of soft soil in offshore areas may lead to the amplification of vibration received from offshore facilities, especially from the existing fixed-jacket platforms, which were designed without provision to seismicity, as in Malaysian water. Therefore, this study was designed to develop a seismic microzonation map and a soil amplification factor map according to soil type; we propose horizontal response spectra and site coefficient values (Ca and Cv) for the Malay Basin. A one-dimensional nonlinear analysis of layered soil (NERA) was used in the ground response analysis for six selected seismic events under five return periods of 100, 200, 500, 1000, and 2500 years. Soil amplification factors for soil types D and E showed a decreasing trend from 100 years to 2500 years. Two designed horizontal response spectra are proposed (for soil type D and E) under average and envelope conditions; a comparison with ISO showed that the proposed spectra were higher, especially for soil type E. To summarize, the seismicity effect should be included in the development of offshore industries as findings indicated that soil amplification occurred in soil types D and E at the Malay Basin.
- 4 July 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (7) , 1711-1739
Finite Element Study: Rocking Wall-Floor Connection of Precast Concrete Load-Bearing Structures Subjected to Quasi-Static Lateral Loading
This paper proposes a novel semi-rigid rocking wall-floor connection. To study its seismic behavior, a preliminary study using finite element modeling (FEM) has been conducted to perceive the rocking wall response towards the precast plank before conducting a physical experimental testing in the laboratory. The finite element model was developed to investigate the lateral quasi-static-load response of the isolated rocking wall system. Subsequently, the rocking wall model was further extended by incorporating a precast concrete plank using the proposed connection. The finite element model of the rocking wall showed a good correlation with the analytical model. Furthermore, the study showed that a semi-rigid connection would result in an overstrength that should be considered when designing the rocking wall.
- 4 July 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (7) , 1711-1739
Finite Element Study: Rocking Wall-Floor Connection of Precast Concrete Load-Bearing Structures Subjected to Quasi-Static Lateral Loading
This paper proposes a novel semi-rigid rocking wall-floor connection. To study its seismic behavior, a preliminary study using finite element modeling (FEM) has been conducted to perceive the rocking wall response towards the precast plank before conducting a physical experimental testing in the laboratory. The finite element model was developed to investigate the lateral quasi-static-load response of the isolated rocking wall system. Subsequently, the rocking wall model was further extended by incorporating a precast concrete plank using the proposed connection. The finite element model of the rocking wall showed a good correlation with the analytical model. Furthermore, the study showed that a semi-rigid connection would result in an overstrength that should be considered when designing the rocking wall.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 19 (1)
Comparison of Seismic Response Corner Beam-Column Joint with and without Fuse Bars Under In-Plane Lateral Cyclic Loading
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 19 (1)
Open AccessComparison of Seismic Response Corner Beam-Column Joint with and without Fuse Bars Under In-Plane Lateral Cyclic Loading
- 26 May 2021
- Published by Springer Nature
- p. 67-82
Earthquake Fuse Bar as Smart Material in Improving Seismic Performance of Beam-Column Joint During Earthquakes
- 26 May 2021
- Published by Springer Nature
- p. 67-82
Earthquake Fuse Bar as Smart Material in Improving Seismic Performance of Beam-Column Joint During Earthquakes
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1062 (1) , 012038
Modelling and Validation of Seismic Performance for Corner and Interior Beam-column Joint Using HYSTERES Program
The validation between experimental and modelled hysteresis loops is a preliminary work in determining the dynamic behaviour of the beam-column joints under earthquake excitations using Ruaumoko 2D program. However, this paper only focuses on accurately modelling the hysteresis loops of corner and interior beam-column joint using the HYSTERES Program. The corner and interior beam-column joints were designed using Eurocode 8 and equipped with unbonded fuse-bars which acts as passive energy dissipators. The hysteresis loops were modelled based on the input parameters obtained from the experimental hysteresis loops. From the HYSTERES program, the Pampanin Reinforced Concrete Beam-Column Joint was chosen to represent the hysteretic behaviour (load versus displacement) for overall seismic behaviour of these joints. The lateral strength capacity, stiffness, ductility and equivalent viscous damping from experimental and modelled hysteresis loops were then compared, and the percentage difference from both hysteresis loops was calculated. Based on the outcomes, there are some parameters which have shown good agreement, and this proves the effectiveness of using HYSTERES program in modelling the hysteresis loops of the beam-column joints.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1062 (1) , 012038
Open AccessModelling and Validation of Seismic Performance for Corner and Interior Beam-column Joint Using HYSTERES Program
The validation between experimental and modelled hysteresis loops is a preliminary work in determining the dynamic behaviour of the beam-column joints under earthquake excitations using Ruaumoko 2D program. However, this paper only focuses on accurately modelling the hysteresis loops of corner and interior beam-column joint using the HYSTERES Program. The corner and interior beam-column joints were designed using Eurocode 8 and equipped with unbonded fuse-bars which acts as passive energy dissipators. The hysteresis loops were modelled based on the input parameters obtained from the experimental hysteresis loops. From the HYSTERES program, the Pampanin Reinforced Concrete Beam-Column Joint was chosen to represent the hysteretic behaviour (load versus displacement) for overall seismic behaviour of these joints. The lateral strength capacity, stiffness, ductility and equivalent viscous damping from experimental and modelled hysteresis loops were then compared, and the percentage difference from both hysteresis loops was calculated. Based on the outcomes, there are some parameters which have shown good agreement, and this proves the effectiveness of using HYSTERES program in modelling the hysteresis loops of the beam-column joints.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 17 (6)
Review on the rocking wall systems as a self-centering mechanism and its interaction with floor diaphragm in precast concrete structures
The severe damage of precast concrete wall structures that have been recorded in the past earthquake has led to the innovation of the rocking wall concept which can demonstrate free or minimum damage aftershock of an earthquake. Furthermore, extensive research works have been well conducted in the past three decades on the establishment of precast rocking wall systems, designs, details, and techniques. Despite this extensive development, little attention has been devoted to investigate the interaction between the rocking wall systems and the flooring diaphragm. The historical perspective on the development of rocking wall systems over the past few decades in the precast concrete structures is presented. Subsequently, the limited research works on the interaction of precast rocking wall to the floor diaphragm are described. Apart from that, this paper attempts to highlight the application of rocking wall systems in the context of precast connection for the precast load-bearing structures. In this contribution, the precast rocking wall-floor connection for precast load-bearing structures is proposed and presented in this paper.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 17 (6)
Open AccessReview on the rocking wall systems as a self-centering mechanism and its interaction with floor diaphragm in precast concrete structures
The severe damage of precast concrete wall structures that have been recorded in the past earthquake has led to the innovation of the rocking wall concept which can demonstrate free or minimum damage aftershock of an earthquake. Furthermore, extensive research works have been well conducted in the past three decades on the establishment of precast rocking wall systems, designs, details, and techniques. Despite this extensive development, little attention has been devoted to investigate the interaction between the rocking wall systems and the flooring diaphragm. The historical perspective on the development of rocking wall systems over the past few decades in the precast concrete structures is presented. Subsequently, the limited research works on the interaction of precast rocking wall to the floor diaphragm are described. Apart from that, this paper attempts to highlight the application of rocking wall systems in the context of precast connection for the precast load-bearing structures. In this contribution, the precast rocking wall-floor connection for precast load-bearing structures is proposed and presented in this paper.