Chiara Capelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chiara Capelli has a total of 537 co-authors. Here are the top co-authors by number of shared publications:
- Laura Baudis
Physik-Institut, University of Zurich, 8057 Zürich, Switzerland
16 shared publications - Alexander Bismark
Physik-Institut, University of Zurich, 8057 Zürich, Switzerland
15 shared publications - Christian Wittweg
Physik-Institut, University of Zurich, 8057 Zürich, Switzerland
15 shared publications - A. P. Cimental Ch'Avez
Physik-Institut, University of Zurich, 8057 Zürich, Switzerland
14 shared publications - Jelle Aalbers
Nikhef and the University of Groningen, Van Swinderen Institute, 9747AG Groningen, Netherlands
14 shared publications - Juehang Qin
Department of Physics and Astronomy, Rice University, Houston, Texas 77005, USA
14 shared publications
Latest Publications
- Open Access
- 14 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (12) , 121001
Constraints on Solar Reflected Dark Matter from XENON1T and XENONnT Data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the standard halo model, keV–MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter (DM) by considering dark matter–electron scattering, employing dedicated event selections to reduce the detection threshold and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between 4.6 and 20 keV / c 2 and between 0.2 and 2 MeV / c 2 , reaching a minimum of 3.41 × 10 − 39 cm 2 for a mass of 0.3 MeV / c 2 at 90% confidence level.
- 14 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (12) , 121001
Open AccessConstraints on Solar Reflected Dark Matter from XENON1T and XENONnT Data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the standard halo model, keV–MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter (DM) by considering dark matter–electron scattering, employing dedicated event selections to reduce the detection threshold and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between 4.6 and 20 keV / c 2 and between 0.2 and 2 MeV / c 2 , reaching a minimum of 3.41 × 10 − 39 cm 2 for a mass of 0.3 MeV / c 2 at 90% confidence level.
- Open Access
- 28 August 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (9) , 091807
Probing the Solar B 8 Neutrino Fog with XENONnT
We report a 3.3 σ measurement of coherent elastic neutrino-nucleus scattering from solar B 8 neutrinos using a 6.77 t × yr exposure from the XENONnT experiment, inferring a solar B 8 neutrino flux of ( 5 − 2 + 3 ) × 10 6 cm − 2 s − 1 , consistent with previous measurements. In the presence of the B 8 “neutrino fog,” we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV / c 2 spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at ∼ 0.02 GeV / c momentum transfer and constrain physics beyond the Standard Model.
- 28 August 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (9) , 091807
Open AccessProbing the Solar B 8 Neutrino Fog with XENONnT
We report a 3.3 σ measurement of coherent elastic neutrino-nucleus scattering from solar B 8 neutrinos using a 6.77 t × yr exposure from the XENONnT experiment, inferring a solar B 8 neutrino flux of ( 5 − 2 + 3 ) × 10 6 cm − 2 s − 1 , consistent with previous measurements. In the presence of the B 8 “neutrino fog,” we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV / c 2 spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at ∼ 0.02 GeV / c momentum transfer and constrain physics beyond the Standard Model.
- Open Access
- 24 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 866
Characterisation of the Bedretto underground site for fundamental physics experiments
Underground laboratories provide the ultra-low background and low-vibration environments essential for rare-event searches, gravitational-wave detection, and quantum-sensing technologies. We report a comprehensive environmental characterisation of the Bedretto tunnel in Ticino, Switzerland, a site offering horizontal access, excellent infrastructure, and the potential to be Europe’s second-deepest and quietest underground laboratory. At the prospective physics site, located beneath a granite overburden exceeding 1400 m, we measure fluxes of: cosmic-muon $$(2.54~\pm ~0.97)~\times 10^{-8}~\upmu /\textrm{s} \,\, /\textrm{cm}^2$$ , $$\gamma $$ -ray $$5.67\pm 0.37\, \gamma /\text {cm}^2/$$ $$\text {sec}$$ , and neutron fluxes $$(5.56 \pm 0.26)\times 10^{-5}~\textrm{neutrons}/\textrm{cm}^2/$$ $$\textrm{sec}$$ , as well as the radon concentration, magnetic-field power spectrum, and seismic backgrounds. The muon flux is suppressed by six orders of magnitude relative to the surface, consistent with an effective depth of about 4000 m water equivalent. Gamma-ray and neutron measurements reflect the local geology and guide shielding requirements for future particle and nuclear physics experiments. Magnetic and seismic noise levels are found to be exceptionally low, meeting or exceeding the criteria for next-generation atom-interferometric gravitational-wave detectors. These results establish the site as a highly competitive, accessible deep-underground location for fundamental-physics experiments.- 24 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 866
Open AccessCharacterisation of the Bedretto underground site for fundamental physics experiments
Underground laboratories provide the ultra-low background and low-vibration environments essential for rare-event searches, gravitational-wave detection, and quantum-sensing technologies. We report a comprehensive environmental characterisation of the Bedretto tunnel in Ticino, Switzerland, a site offering horizontal access, excellent infrastructure, and the potential to be Europe’s second-deepest and quietest underground laboratory. At the prospective physics site, located beneath a granite overburden exceeding 1400 m, we measure fluxes of: cosmic-muon $$(2.54~\pm ~0.97)~\times 10^{-8}~\upmu /\textrm{s} \,\, /\textrm{cm}^2$$ , $$\gamma $$ -ray $$5.67\pm 0.37\, \gamma /\text {cm}^2/$$ $$\text {sec}$$ , and neutron fluxes $$(5.56 \pm 0.26)\times 10^{-5}~\textrm{neutrons}/\textrm{cm}^2/$$ $$\textrm{sec}$$ , as well as the radon concentration, magnetic-field power spectrum, and seismic backgrounds. The muon flux is suppressed by six orders of magnitude relative to the surface, consistent with an effective depth of about 4000 m water equivalent. Gamma-ray and neutron measurements reflect the local geology and guide shielding requirements for future particle and nuclear physics experiments. Magnetic and seismic noise levels are found to be exceptionally low, meeting or exceeding the criteria for next-generation atom-interferometric gravitational-wave detectors. These results establish the site as a highly competitive, accessible deep-underground location for fundamental-physics experiments. - Open Access
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Low-energy nuclear recoil calibration of XENONnT with a Y 88 Be photoneutron source
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used an Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ± 12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V / cm between 0.3 (0.7) keV NR and 5.0 keV NR . This calibration is crucial for accurately measuring the solar B 8 neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV / c 2 .
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessLow-energy nuclear recoil calibration of XENONnT with a Y 88 Be photoneutron source
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used an Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ± 12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V / cm between 0.3 (0.7) keV NR and 5.0 keV NR . This calibration is crucial for accurately measuring the solar B 8 neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV / c 2 .
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06007
High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06007
Open AccessHigh-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.
- Open Access
- 23 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 120201
Challenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
- 23 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 120201
Open AccessChallenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
- Open Access
High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by $\sim$1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of $\sim$100 $μ$s, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMux) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor. Each multiplexing readout module comprises ten superconducting resonators in the MHz range and a superconducting quantum interference device (SQUID), interfaced to high-bandwidth field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency feedback.
Open AccessHigh-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by $\sim$1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of $\sim$100 $μ$s, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMux) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor. Each multiplexing readout module comprises ten superconducting resonators in the MHz range and a superconducting quantum interference device (SQUID), interfaced to high-bandwidth field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency feedback.
- Open Access
Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background.Open AccessLight Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background. - Open Access
Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.Open AccessConstraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level. - 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1698-1705
Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID
Superconducting transition-edge sensor (TES) detectors have been the standard in Cosmic Microwave Background experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this paper we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. We find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1698-1705
Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID
Superconducting transition-edge sensor (TES) detectors have been the standard in Cosmic Microwave Background experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this paper we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. We find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.