Simon Reiss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Simon Reiss has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Michael Bock
Division of Medical Physics, Department of Diagnostic and Interventional Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany
13 shared publications - Ali Caglar Özen
Division of Medical Physics, Department of Diagnostic and Interventional Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany
8 shared publications Constantin von Zur Mühlen
Department of Cardiology and Angiology, Faculty of Medicine, University Heart Center Freiburg-Bad Krozingen, University of Freiburg, Freiburg, Germany
6 shared publications- Alexander Maier
Department of Cardiology and Angiology University Heart Center Freiburg‐Bad Krozingen, Faculty of Medicine ‐ University of Freiburg Freiburg Germany
5 shared publications - Johannes Fischer
Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
5 shared publications Thomas Lottner
Department of Diagnostic and Interventional Radiology, Division of Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
5 shared publications
Latest Publications
- Open Access
- 19 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2629-2641
Comparative Performance Analysis of an Open Source Motion‐Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths—A Pilot Study
Purpose: To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods: Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers. DTI and SNR analysis was performed to investigate protocol efficacy. Results: The sequences performed well at the task of imaging short axis views of the myocardium and producing data suitable for diffusion tensor imaging analysis. Significant differences in sequence performance across different systems and within the same system were revealed. Relative SNR utilizing the strongest available gradient system yielded up to 80% more SNR than the weakest tested system. Relative SNR obtained from the same sequence at different scanners differed by up to 42%, suggesting hardware impacts that warrant further investigation. Conclusion: The presented sequence framework allows for an easy starting point into cardiac diffusion tensor imaging and opens the door to further analysis of hardware impacts on performance.
- 19 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2629-2641
Open AccessComparative Performance Analysis of an Open Source Motion‐Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths—A Pilot Study
Purpose: To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods: Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers. DTI and SNR analysis was performed to investigate protocol efficacy. Results: The sequences performed well at the task of imaging short axis views of the myocardium and producing data suitable for diffusion tensor imaging analysis. Significant differences in sequence performance across different systems and within the same system were revealed. Relative SNR utilizing the strongest available gradient system yielded up to 80% more SNR than the weakest tested system. Relative SNR obtained from the same sequence at different scanners differed by up to 42%, suggesting hardware impacts that warrant further investigation. Conclusion: The presented sequence framework allows for an easy starting point into cardiac diffusion tensor imaging and opens the door to further analysis of hardware impacts on performance.
- Open Access
- 30 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2331-2344
RF‐Shielding of Laser‐Cut Venous Stents: Calculations, Simulations, and Experiments
Purpose: To develop an analytical model of the RF‐shielding of laser‐cut venous stents for different orientations and stent geometries. Methods: Laser‐cut venous stents are modeled as a grid composed of circular and rectangular loops. As these loops are orthogonal they shield different components of the transmit RF field. The shielding is calculated using Faraday's induction law, taking into account the self‐inductance and mutual coupling of circular and rectangular loops, and Biot–Savart's law. The shielding of 95 stent‐mimicking models was calculated, and numerical simulations and measurements were performed at both 1.5 and 3T for validation. Results: The shielding of circular and rectangular loops differed by less than 3.3% and 10% between calculations, simulations, and measurements. The overall stent length had negligible impact on the shielding (< 8%). The combined shielding of both loop types showed deviations of less than 10% compared to stent models with varying cell sizes. Orienting the stents at an oblique angle other than 0° or 90° to B 0 , the model‐predicted shielding values deviated by less than 14%/10% from the measured values at 1.5 T/3 T. Conclusion: The model allows for the calculation of the B 1 shielding of laser‐cut venous stents depending on their geometry and orientation relative to B 0 . Thus, it may help to adapt imaging parameters such as the flip angle to optimize monitoring of stent patency.
- 30 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2331-2344
Open AccessRF‐Shielding of Laser‐Cut Venous Stents: Calculations, Simulations, and Experiments
Purpose: To develop an analytical model of the RF‐shielding of laser‐cut venous stents for different orientations and stent geometries. Methods: Laser‐cut venous stents are modeled as a grid composed of circular and rectangular loops. As these loops are orthogonal they shield different components of the transmit RF field. The shielding is calculated using Faraday's induction law, taking into account the self‐inductance and mutual coupling of circular and rectangular loops, and Biot–Savart's law. The shielding of 95 stent‐mimicking models was calculated, and numerical simulations and measurements were performed at both 1.5 and 3T for validation. Results: The shielding of circular and rectangular loops differed by less than 3.3% and 10% between calculations, simulations, and measurements. The overall stent length had negligible impact on the shielding (< 8%). The combined shielding of both loop types showed deviations of less than 10% compared to stent models with varying cell sizes. Orienting the stents at an oblique angle other than 0° or 90° to B 0 , the model‐predicted shielding values deviated by less than 14%/10% from the measured values at 1.5 T/3 T. Conclusion: The model allows for the calculation of the B 1 shielding of laser‐cut venous stents depending on their geometry and orientation relative to B 0 . Thus, it may help to adapt imaging parameters such as the flip angle to optimize monitoring of stent patency.
- Open Access
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Pulsed field ablation compared to thermal ablation techniques in atrial fibrillation: a German-wide in-hospital safety analysis
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Open AccessPulsed field ablation compared to thermal ablation techniques in atrial fibrillation: a German-wide in-hospital safety analysis
- Open Access
- 19 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Cardiac MRI of differing ischemia and reperfusion times in a myocardial infarction pig model
The closed-chest porcine model of myocardial ischemia is an essential tool for preclinical research in cardiology. Current literature reports heterogeneous results regarding myocardial ischemia and reperfusion injury (IRI). This retrospective analysis presents our experience and cardiac magnetic resonance (CMR) findings while establishing a porcine IRI model. 8 male and 12 female juvenile German Landrace pigs received general anesthesia and antiarrhythmic pre-treatment. Myocardial ischemia was induced using transfemoral catheterization and balloon-occlusion of the left anterior descending (LAD) or the left circumflex (LCX) coronary artery under X-ray fluoroscopy guidance. The duration of ischemia varied from 30 to 90 min. CMR was performed at a clinical 3 T system including functional imaging, T1 and T2 mapping and late gadolinium enhancement (LGE) 2–5 h or three days post-reperfusion. Ventricular fibrillation (VF) was a recurrent event, which was counteracted with amiodarone, high blood potassium levels and in one case with propranolol. Males were more likely to experience VF than females and 15 of 20 animals survived the experiment. Resuscitation was required in 47% of the further analyzed animals. CMR revealed IRI in 14 of 15 animals in cardiac segments analogous to those supplied by the respective artery in humans. The mean left ventricular ejection fraction was reduced to 52% and 47% of animals had an impaired wall motion. Ischemia durations of 30–45 min did not result in LGE and in no significant T2 increase, whereas T1 was significantly increased (p = 0.02). Occlusion durations of 60–90 min resulted in LGE and T1 and T2 values both increased compared to 30–45 min of ischemia (p < 0.001 for T1 and p = 0.021 for T2). CMR of porcine myocardial IRI showed varying T1 and T2 patterns for different ischemia and reperfusion durations. For IRI, T1 elevation was the most sensitive marker. Significant myocardial infarction indicated by LGE only occurred after ischemic durations ≥ 60 min; thus, an appropriate occlusion duration must be chosen in pigs to create myocardial IRI for scientific studies.
- 19 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessCardiac MRI of differing ischemia and reperfusion times in a myocardial infarction pig model
The closed-chest porcine model of myocardial ischemia is an essential tool for preclinical research in cardiology. Current literature reports heterogeneous results regarding myocardial ischemia and reperfusion injury (IRI). This retrospective analysis presents our experience and cardiac magnetic resonance (CMR) findings while establishing a porcine IRI model. 8 male and 12 female juvenile German Landrace pigs received general anesthesia and antiarrhythmic pre-treatment. Myocardial ischemia was induced using transfemoral catheterization and balloon-occlusion of the left anterior descending (LAD) or the left circumflex (LCX) coronary artery under X-ray fluoroscopy guidance. The duration of ischemia varied from 30 to 90 min. CMR was performed at a clinical 3 T system including functional imaging, T1 and T2 mapping and late gadolinium enhancement (LGE) 2–5 h or three days post-reperfusion. Ventricular fibrillation (VF) was a recurrent event, which was counteracted with amiodarone, high blood potassium levels and in one case with propranolol. Males were more likely to experience VF than females and 15 of 20 animals survived the experiment. Resuscitation was required in 47% of the further analyzed animals. CMR revealed IRI in 14 of 15 animals in cardiac segments analogous to those supplied by the respective artery in humans. The mean left ventricular ejection fraction was reduced to 52% and 47% of animals had an impaired wall motion. Ischemia durations of 30–45 min did not result in LGE and in no significant T2 increase, whereas T1 was significantly increased (p = 0.02). Occlusion durations of 60–90 min resulted in LGE and T1 and T2 values both increased compared to 30–45 min of ischemia (p < 0.001 for T1 and p = 0.021 for T2). CMR of porcine myocardial IRI showed varying T1 and T2 patterns for different ischemia and reperfusion durations. For IRI, T1 elevation was the most sensitive marker. Significant myocardial infarction indicated by LGE only occurred after ischemic durations ≥ 60 min; thus, an appropriate occlusion duration must be chosen in pigs to create myocardial IRI for scientific studies.
- Open Access
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1663-1671
Myocardial perfusion mapping with intra‐arterial spin labeling: Optimization of the labeling efficiency
Purpose: Intra‐arterial spin labeling (iASL) applies a labeling pulse from a transmit coil at the tip of the catheter for regional myocardial perfusion measurements during MR‐guided catheterizations. This study investigates the labeling efficiency of catheter‐mounted coils under varying conditions to enable robust iASL measurements. Methods: The labeling efficiency was assessed by analytical calculations, numerical simulations, and in vitro measurements at 3 T. Analytical solutions were provided for various simplified field distributions, and a numerical simulation was used to calculate for different catheter coil designs using the Biot‐Savart Law. Using these fields, the RF excitation of the blood magnetization flowing around the catheter was calculated using the Bloch equation. Finally, in vitro measurements were performed in a flow phantom using loop and solenoid catheter coils. Results: fields produced by the catheter coils result in a saturation of the mean magnetization when the applied pulse exceeds a threshold power. This threshold power varies between 1 and 25 mW for different coil designs, flow velocities, and geometric parameters. Conclusion: iASL creates a saturation that is robust against variations in flow and coil positioning. The simulations could determine the threshold pulse power for robust iASL excitation, which needs to be adapted to applications in different vessels. Thus, iASL may provide an efficient alternative to perfusion measurements with exogenous contrast agents during MR‐guided interventions.
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1663-1671
Open AccessMyocardial perfusion mapping with intra‐arterial spin labeling: Optimization of the labeling efficiency
Purpose: Intra‐arterial spin labeling (iASL) applies a labeling pulse from a transmit coil at the tip of the catheter for regional myocardial perfusion measurements during MR‐guided catheterizations. This study investigates the labeling efficiency of catheter‐mounted coils under varying conditions to enable robust iASL measurements. Methods: The labeling efficiency was assessed by analytical calculations, numerical simulations, and in vitro measurements at 3 T. Analytical solutions were provided for various simplified field distributions, and a numerical simulation was used to calculate for different catheter coil designs using the Biot‐Savart Law. Using these fields, the RF excitation of the blood magnetization flowing around the catheter was calculated using the Bloch equation. Finally, in vitro measurements were performed in a flow phantom using loop and solenoid catheter coils. Results: fields produced by the catheter coils result in a saturation of the mean magnetization when the applied pulse exceeds a threshold power. This threshold power varies between 1 and 25 mW for different coil designs, flow velocities, and geometric parameters. Conclusion: iASL creates a saturation that is robust against variations in flow and coil positioning. The simulations could determine the threshold pulse power for robust iASL excitation, which needs to be adapted to applications in different vessels. Thus, iASL may provide an efficient alternative to perfusion measurements with exogenous contrast agents during MR‐guided interventions.
- Open Access
- 30 May 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 38 (6) , 1011-1021
Radial Hadamard-encoded 19F-MRI
Objectives: Developing a 19 F imaging method to acquire images of the molecular inflammation tracer perfluorooctyl bromide (PFOB) without chemical shift artifacts. Materials and methods: PFOB is a molecular tracer that can be used to track the response of myeloid cells. However, imaging of PFOB with 19 F-MRI is challenging due to its complex spectrum which leads to unwanted chemical shift artifacts. Spectral HE allows for separate reconstructions of each peak of the PFOB spectrum, which was combined into a single image after resonance shift correction. In this work, a Hadamard-encoded (HE) radial 3D UTE sequence was tested in phantoms and in vivo in a pig, measuring the 19 F signal in the spleen at different times after injection. Results: Chemical shift artifacts were effectively suppressed with HE, and an SNR > 100 was observed for the 19 F signal in the spleen 2 days after injection. The signal decreased over time, and 7 days after injection it was reduced by 30%. Discussion: Chemical shift artifact correction using HE allowed for in vivo 19 F PFOB imaging of labeled monocytes with a high SNR. Compared to spectrally selective excitation, HE increased the PFOB 19 F-MRI signal by 10%, and the simple HE-algorithm could be directly integrated into the image reconstruction of the MRI system.
- 30 May 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 38 (6) , 1011-1021
Open AccessRadial Hadamard-encoded 19F-MRI
Objectives: Developing a 19 F imaging method to acquire images of the molecular inflammation tracer perfluorooctyl bromide (PFOB) without chemical shift artifacts. Materials and methods: PFOB is a molecular tracer that can be used to track the response of myeloid cells. However, imaging of PFOB with 19 F-MRI is challenging due to its complex spectrum which leads to unwanted chemical shift artifacts. Spectral HE allows for separate reconstructions of each peak of the PFOB spectrum, which was combined into a single image after resonance shift correction. In this work, a Hadamard-encoded (HE) radial 3D UTE sequence was tested in phantoms and in vivo in a pig, measuring the 19 F signal in the spleen at different times after injection. Results: Chemical shift artifacts were effectively suppressed with HE, and an SNR > 100 was observed for the 19 F signal in the spleen 2 days after injection. The signal decreased over time, and 7 days after injection it was reduced by 30%. Discussion: Chemical shift artifact correction using HE allowed for in vivo 19 F PFOB imaging of labeled monocytes with a high SNR. Compared to spectrally selective excitation, HE increased the PFOB 19 F-MRI signal by 10%, and the simple HE-algorithm could be directly integrated into the image reconstruction of the MRI system.
- Open Access
- 15 October 2024
- Published by Wiley in Advanced Science
- Vol. 11 (45) , e2407704
Thermally Drawn Polymeric Catheters for MR‐Guided Cardiovascular Intervention
Cardiovascular diseases (CVDs), including congenital heart diseases (CHD), present significant global health challenges, emphasizing the need for safe and effective treatment modalities. Fluoroscopy‐guided endovascular interventions are widely utilized but raise concerns about ionizing radiation, especially in pediatric cases. Magnetic resonance imaging (MRI) offers a radiation‐free alternative with superior soft tissue visualization and functional insights. However, the lack of compatible instruments remains a major obstacle. An adapted thermal drawing platform that enables low‐cost and rapid prototyping of instruments for MR‐guided endovascular interventions is introduced. This platform is demonstrated through the development of two exemplary catheter systems: a tendon‐driven steerable catheter with helical lumina and an active tracking Tiger‐shaped catheter with an embedded coaxial wire. These catheters exhibit mechanical properties comparable to commercial counterparts and show promising outcomes in both in vitro and in vivo feasibility testing. This scalable thermal drawing platform addresses the limitations of existing manufacturing approaches and facilitates the exploration of diverse designs, potentially accelerating advancements in catheter technologies for MR‐guided cardiovascular interventions.
- 15 October 2024
- Published by Wiley in Advanced Science
- Vol. 11 (45) , e2407704
Open AccessThermally Drawn Polymeric Catheters for MR‐Guided Cardiovascular Intervention
Cardiovascular diseases (CVDs), including congenital heart diseases (CHD), present significant global health challenges, emphasizing the need for safe and effective treatment modalities. Fluoroscopy‐guided endovascular interventions are widely utilized but raise concerns about ionizing radiation, especially in pediatric cases. Magnetic resonance imaging (MRI) offers a radiation‐free alternative with superior soft tissue visualization and functional insights. However, the lack of compatible instruments remains a major obstacle. An adapted thermal drawing platform that enables low‐cost and rapid prototyping of instruments for MR‐guided endovascular interventions is introduced. This platform is demonstrated through the development of two exemplary catheter systems: a tendon‐driven steerable catheter with helical lumina and an active tracking Tiger‐shaped catheter with an embedded coaxial wire. These catheters exhibit mechanical properties comparable to commercial counterparts and show promising outcomes in both in vitro and in vivo feasibility testing. This scalable thermal drawing platform addresses the limitations of existing manufacturing approaches and facilitates the exploration of diverse designs, potentially accelerating advancements in catheter technologies for MR‐guided cardiovascular interventions.
- Open Access
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 40267-40278
eGantryMate: A Piezo-Motor-Driven Lean and Flexible Assistance System for MR-Guided Interventions at 1.5T
In closed-bore MRI units, assistance systems play a crucial role in overcoming patient access limitations during percutaneous interventions. In this work, we present eGantryMate, a piezo-motor-driven assistance system specifically designed for MR-guided needle interventions in high-field MRI systems. eGantryMate consists of an instrument positioning unit and a control unit equipped with piezo motors, radiofrequency filters, and shielding. Paired with a real-time tracking sequence for automatic marker detection and projection of the instrument trajectory onto the MR image, eGantryMate enables precise and efficient needle interventions. Targeting experiments were performed by inserting a biopsy needle into a series of fiducial targets in a phantom, and usability experiments were conducted in vivo without needle insertion. The results show artifact-free MR imaging, minimal temperature rise on the instrument positioning unit, and precise targeting capabilities. These findings demonstrate eGantryMate’s ability to perform real-time needle alignments and insertions within the magnet bore, highlighting its potential to enhance the acceptability and efficacy of MR-guided interventions.
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 40267-40278
Open AccesseGantryMate: A Piezo-Motor-Driven Lean and Flexible Assistance System for MR-Guided Interventions at 1.5T
In closed-bore MRI units, assistance systems play a crucial role in overcoming patient access limitations during percutaneous interventions. In this work, we present eGantryMate, a piezo-motor-driven assistance system specifically designed for MR-guided needle interventions in high-field MRI systems. eGantryMate consists of an instrument positioning unit and a control unit equipped with piezo motors, radiofrequency filters, and shielding. Paired with a real-time tracking sequence for automatic marker detection and projection of the instrument trajectory onto the MR image, eGantryMate enables precise and efficient needle interventions. Targeting experiments were performed by inserting a biopsy needle into a series of fiducial targets in a phantom, and usability experiments were conducted in vivo without needle insertion. The results show artifact-free MR imaging, minimal temperature rise on the instrument positioning unit, and precise targeting capabilities. These findings demonstrate eGantryMate’s ability to perform real-time needle alignments and insertions within the magnet bore, highlighting its potential to enhance the acceptability and efficacy of MR-guided interventions.
- Open Access
- 5 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Combination of high resolution MRI with 3D-printed needle guides for ex vivo myocardial biopsies
Magnetic resonance imaging (MRI) provides a multitude of techniques to detect and characterize myocardial infarction. To correlate MRI findings with histology, in most cases terminal animal studies are performed; however, precise extraction and spatial correlation of myocardial tissue samples to MRI image data is difficult. In this proof of concept study, we present a 3D-printing technique to facilitate the extraction of tissue samples from myocardial regions. Initially, seven pig hearts embedded in formaldehyde were imaged on a clinical 3 T system to define biopsy targets on high resolution ex vivo images. Magnitude images and R2*-maps acquired with a 3D multi-echo gradient echo sequence and 0.58 mm isotropic resolution were used to create digital models of the cardiac anatomy. Biopsy guides were 3D-printed to steer the extraction of myocardial samples. In total, 61 tissue samples were extracted with an average offset of the tissue sample location from the target location of 0.59 ± 0.36 mm. This offset was not dependent on the distance of the target point to the epicardial surface. Myocardial tissue could be extracted from all samples. The presented method enables extraction of myocardial tissue samples that are selected by ex vivo MRI with submillimeter precision.
- 5 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Open AccessCombination of high resolution MRI with 3D-printed needle guides for ex vivo myocardial biopsies
Magnetic resonance imaging (MRI) provides a multitude of techniques to detect and characterize myocardial infarction. To correlate MRI findings with histology, in most cases terminal animal studies are performed; however, precise extraction and spatial correlation of myocardial tissue samples to MRI image data is difficult. In this proof of concept study, we present a 3D-printing technique to facilitate the extraction of tissue samples from myocardial regions. Initially, seven pig hearts embedded in formaldehyde were imaged on a clinical 3 T system to define biopsy targets on high resolution ex vivo images. Magnitude images and R2*-maps acquired with a 3D multi-echo gradient echo sequence and 0.58 mm isotropic resolution were used to create digital models of the cardiac anatomy. Biopsy guides were 3D-printed to steer the extraction of myocardial samples. In total, 61 tissue samples were extracted with an average offset of the tissue sample location from the target location of 0.59 ± 0.36 mm. This offset was not dependent on the distance of the target point to the epicardial surface. Myocardial tissue could be extracted from all samples. The presented method enables extraction of myocardial tissue samples that are selected by ex vivo MRI with submillimeter precision.
- Open Access
- 10 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2388-2399
Simultaneous T2‐weighted real‐time MRI of two orthogonal slices
Purpose: MR guidance is used during therapy to detect and compensate for lesion motion. T2‐weighted MRI often has a superior lesion contrast in comparison to T1‐weighted real‐time imaging. The purpose of this work was to design a fast T2‐weighted sequence capable of simultaneously acquiring two orthogonal slices, enabling real‐time tracking of lesions.Methods: To generate a T2 contrast in two orthogonal slices simultaneously, a sequence (Ortho‐SFFP‐Echo) was designed that samples the T2‐weighted spin echo (S−) signal in a TR‐interleaved acquisition of two slices. Slice selection and phase‐encoding directions are swapped between the slices, leading to a unique set of spin‐echo signal conditions. To minimize motion‐related signal dephasing, additional flow‐compensation strategies are implemented. In both the abdominal breathing phantom and in vivo experiments, a time series was acquired using Ortho‐SSFP‐Echo. The centroid of the target was tracked in postprocessing steps.Results: In the phantom, the lesion could be identified and delineated in the dynamic images. In the volunteer experiments, the kidney was visualized with a T2 contrast at a temporal resolution of 0.45 s under free‐breathing conditions. A respiratory belt demonstrated a strong correlation with the time course of the kidney centroid in the head–foot direction. A hypointense saturation band at the slice overlap did not inhibit lesion tracking in the semi‐automatic postprocessing steps.Conclusion: The Ortho‐SFFP‐Echo sequence delivers real‐time images with a T2‐weighted contrast in two orthogonal slices. The sequence allows for simultaneous acquisition, which could be beneficial for real‐time motion tracking in radiotherapy or interventional MRI.
- 10 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2388-2399
Open AccessSimultaneous T2‐weighted real‐time MRI of two orthogonal slices
Purpose: MR guidance is used during therapy to detect and compensate for lesion motion. T2‐weighted MRI often has a superior lesion contrast in comparison to T1‐weighted real‐time imaging. The purpose of this work was to design a fast T2‐weighted sequence capable of simultaneously acquiring two orthogonal slices, enabling real‐time tracking of lesions.Methods: To generate a T2 contrast in two orthogonal slices simultaneously, a sequence (Ortho‐SFFP‐Echo) was designed that samples the T2‐weighted spin echo (S−) signal in a TR‐interleaved acquisition of two slices. Slice selection and phase‐encoding directions are swapped between the slices, leading to a unique set of spin‐echo signal conditions. To minimize motion‐related signal dephasing, additional flow‐compensation strategies are implemented. In both the abdominal breathing phantom and in vivo experiments, a time series was acquired using Ortho‐SSFP‐Echo. The centroid of the target was tracked in postprocessing steps.Results: In the phantom, the lesion could be identified and delineated in the dynamic images. In the volunteer experiments, the kidney was visualized with a T2 contrast at a temporal resolution of 0.45 s under free‐breathing conditions. A respiratory belt demonstrated a strong correlation with the time course of the kidney centroid in the head–foot direction. A hypointense saturation band at the slice overlap did not inhibit lesion tracking in the semi‐automatic postprocessing steps.Conclusion: The Ortho‐SFFP‐Echo sequence delivers real‐time images with a T2‐weighted contrast in two orthogonal slices. The sequence allows for simultaneous acquisition, which could be beneficial for real‐time motion tracking in radiotherapy or interventional MRI.