Celine Roger-Dalbert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Celine Roger-Dalbert has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Charles K. Cooper
Becton, Dickinson and Company
2 shared publications - Devin S. Gary
Becton, Dickinson and Company
2 shared publications - Jeffrey C. Andrews
Becton, Dickinson and Company
2 shared publications - Amanda Montano
Tricore Reference Laboratory
1 shared publication - Andrew Pekosz
W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins University Bloomberg School of Public Health, Baltimore, MD, USA
1 shared publication - Cameron Burgard
Tricore Reference Laboratory
1 shared publication
Latest Publications
- Open Access
Antigen-based testing but not real-time PCR correlates with SARS-CoV-2 virus culture
SUMMARY: Individuals can test positive for SARS-CoV-2 by real-time polymerase chain reaction (RT-PCR) after no longer being infectious. 1-8 Positive SARS-CoV-2 antigen-based testing exhibits a temporal pattern that corresponds with active, replicating virus and could therefore be a more accurate predictor of an individual’s potential to transmit SARS-CoV-2. 2,3,9 Using the BD Veritor System for Rapid Detection of SARS-CoV-2 later flow antigen detection test, we demonstrate a higher concordance of antigen-positive test results with the presence of cultured, infectious virus when compared to RT-PCR. When compared to infectious virus isolation, the sensitivity of antigen-based testing is similar to RT-PCR. The correlation between SARS-CoV-2 antigen and SARS-CoV-2 culture represents a significant advancement in determining the risk for potential transmissibility beyond that which can be achieved by detection of SARS-CoV-2 genomic RNA. Coupled with a rapid time-to-result, low cost, and scalability, antigen-based testing should facilitate effective implementation of testing and public health interventions that will better contain COVID-19.
Open AccessAntigen-based testing but not real-time PCR correlates with SARS-CoV-2 virus culture
SUMMARY: Individuals can test positive for SARS-CoV-2 by real-time polymerase chain reaction (RT-PCR) after no longer being infectious. 1-8 Positive SARS-CoV-2 antigen-based testing exhibits a temporal pattern that corresponds with active, replicating virus and could therefore be a more accurate predictor of an individual’s potential to transmit SARS-CoV-2. 2,3,9 Using the BD Veritor System for Rapid Detection of SARS-CoV-2 later flow antigen detection test, we demonstrate a higher concordance of antigen-positive test results with the presence of cultured, infectious virus when compared to RT-PCR. When compared to infectious virus isolation, the sensitivity of antigen-based testing is similar to RT-PCR. The correlation between SARS-CoV-2 antigen and SARS-CoV-2 culture represents a significant advancement in determining the risk for potential transmissibility beyond that which can be achieved by detection of SARS-CoV-2 genomic RNA. Coupled with a rapid time-to-result, low cost, and scalability, antigen-based testing should facilitate effective implementation of testing and public health interventions that will better contain COVID-19.
- Open Access
Clinical evaluation of BD Veritor ™ SARS-CoV-2 point-of-care test performance compared to PCR-based testing and versus the Sofia ® 2 SARS Antigen point-of-care test
Objectives: The clinical performance of the BD Veritor™ System for Rapid Detection of SARS-CoV-2 antigen (Veritor), a chromatographic immunoassay that detects the SARS-CoV-2 nucleocapsid antigen as a point-of-care test, was evaluated on nasal specimens from individuals with COVID-19 symptoms. Methods and Materials: Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO]), ≥18 years of age, were utilized to compare Veritor with the Lyra ® SARS-CoV-2 PCR Assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO), ≥18 years of age, were utilized to compare performance of Veritor to that of the Sofia ® 2 SARS Antigen FIA test (Sofia 2). Positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. Results: In study 1, PPA for Veritor, compared to Lyra, ranged from 81.8%-87.5% for 0-1 through 0-6 DSO ranges. In study 2, Veritor had a PPA, NPA, and OPA of 97.4%, 98.1%, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Conclusions: Veritor met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing (≥80% PPA point estimate) for the 0-5 and 0-6 DSO ranges. Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test should facilitate rapid and reliable results for COVID-19 diagnosis utilizing easy-to-collect nasal swabs. Summary: The BD Veritor SARS-CoV-2 antigen test met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing for subjects with COVID-19 symptoms (0-5 days post-onset). BD Veritor and Quidel Sofia 2 antigen tests had good agreement for SARS-CoV-2 detection; discordant analysis favored Veritor.
Open AccessClinical evaluation of BD Veritor ™ SARS-CoV-2 point-of-care test performance compared to PCR-based testing and versus the Sofia ® 2 SARS Antigen point-of-care test
Objectives: The clinical performance of the BD Veritor™ System for Rapid Detection of SARS-CoV-2 antigen (Veritor), a chromatographic immunoassay that detects the SARS-CoV-2 nucleocapsid antigen as a point-of-care test, was evaluated on nasal specimens from individuals with COVID-19 symptoms. Methods and Materials: Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO]), ≥18 years of age, were utilized to compare Veritor with the Lyra ® SARS-CoV-2 PCR Assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO), ≥18 years of age, were utilized to compare performance of Veritor to that of the Sofia ® 2 SARS Antigen FIA test (Sofia 2). Positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. Results: In study 1, PPA for Veritor, compared to Lyra, ranged from 81.8%-87.5% for 0-1 through 0-6 DSO ranges. In study 2, Veritor had a PPA, NPA, and OPA of 97.4%, 98.1%, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Conclusions: Veritor met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing (≥80% PPA point estimate) for the 0-5 and 0-6 DSO ranges. Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test should facilitate rapid and reliable results for COVID-19 diagnosis utilizing easy-to-collect nasal swabs. Summary: The BD Veritor SARS-CoV-2 antigen test met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing for subjects with COVID-19 symptoms (0-5 days post-onset). BD Veritor and Quidel Sofia 2 antigen tests had good agreement for SARS-CoV-2 detection; discordant analysis favored Veritor.