MBMaria Helena Rossy Borges

Maria Helena Rossy Borges

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maria Helena Rossy Borges has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bioactive Glass-Inspired Coating for Implants via Plasma Electrolytic Oxidation: A Preclinical Approach to Enhance Bone Repair in Healing-Impaired Conditions Associated with Diabetes

    by Stéfany Barbosa Alves da Cruz, Raphael Cavalcante Costa, Francieli da Silva Flores, Maria Helena R. Borges, Doris Hissako Matsushita, Martinna Bertolini, Nilson Cristino da Cruz, João Gabriel S. Souza, Edilson Ervolino, Valentim A. R. Barão, et al.

    Diabetes mellitus is a globally prevalent metabolic disorder that impairs wound healing and bone regeneration, compromising outcomes in implant therapies that rely on osseointegration. Advances in precision medicine and bioengineering have driven the development of functionalized implant surfaces to overcome these limitations. Among them, bioactive glass (BG) coatings have emerged as promising candidates to enhance biological responses. Building upon this rationale, we unveiled the osteoinductive potential of a BG-based coating synthesized via plasma electrolytic oxidation (PEO) and its effects on peri-implant bone regeneration in a diabetic rat model. Titanium implants were treated with PEO using a formulation mimicking BG composition (∼45.0 Si, 24.5 Ca, 24.5 Na, 6.0 P; m/v %), and the resulting coating was characterized. Implants with a sandblasted and acid-etched (SLA) surface served as the control. In vivo evaluation was conducted in Wistar rats with streptozotocin-induced diabetes mellitus, followed by tibial implant placement. At 14 and 28 days postimplantation, samples were harvested for histological, immunohistochemical, micro-CT, and histomorphometric analyses. Physicochemical characterization confirmed the synthesis of the PEO-BG coating, which exhibited enhanced surface roughness and wettability compared to SLA controls. A significantly greater area of newly formed bone, increased bone–implant contact, and favorable bone turnover were noted in the PEO-BG group. The expression profiles of BMP-2, RANKL, OPG, and OCN indicated modulation of osteogenic and inflammatory pathways consistent with accelerated bone repair. These findings demonstrate that PEO-BG coating confers robust osteoinductive potential, enhancing peri-implant bone regeneration under compromised diabetic conditions, and highlight its potential for translational application in high-risk populations.


  • Open Access

    Impact of cement- and screw- retained implant prostheses on marginal bone loss

    by João Vicente Calazans Neto, Cícero Andrade Sigilião Celles, Maria Helena Rossy Borges, Samuel Santana Malheiros, Guilherme Almeida Borges, Valentim Adelino Ricardo Barão, Bruna Egumi Nagay

    Aim: The choice between retention systems in implant-supported prostheses impacts marginal bone loss (MBL), a key factor for implant longevity. Due to variability in the findings of systematic reviews, this overview aims to assess the methodological quality and synthesize available evidence from systematic reviews on the effects of cement- versus screw-retained implant-supported prostheses on MBL. Methods: Six databases were searched for systematic reviews comparing MBL in screw- versus cementretained implant-supported prostheses. The methodological quality was assessed using AMSTAR 2, and the MBL effects were classified as favoring cemented, no difference, or favoring screwed systems based on the conclusions of the reviews. Additionally, quantitative data on MBL at different intervals—up to 1, 3, 4, and more than 4 years—were extracted from primary articles and visually plotted for interpretation. Results: The search identified 8 systematic reviews, mainly classified as critically low quality, which found no significant difference in MBL between retention systems. Evaluating the quantitative data, both systems exhibited minor variations over time, with cemented implant-supported prostheses showing slightly less bone loss at the five-year follow-up. Beyond 4 years, both systems demonstrated similar MBL ranges. Conclusion: Both screw-retained and cement-retained implant-supported prostheses appear to be reliable options, with no significant difference in MBL observed in most systematic reviews, especially over longer follow-up periods. However, due to the low quality of existing systematic reviews, conclusions should be approached with caution, underscoring the need for betterdesigned studies to reach a clearer clinical consensus.


  • Open Access

    The role of citric acid in denture cleansing: Effects on biofilm reduction and corrosion resistance of Co-Cr alloys

    by Maria Helena Rossy Borges, Luís Fernando Bandeira Miranda, Samuel Santana Malheiros, Ayrton Geroncio Silva, João Vicente Calazans Neto, Mariana Alves dos Santos, Elidiane Cipriano Rangel, Valentim Adelino Ricardo Barão, Bruna Egumi Nagay

    This in vitro study evaluated the effects of citric acid (CA) on surface properties, biofilm removal, and electrochemical performance of Co-Cr alloys compared to common denture cleansers. Co-Cr discs were divided into five groups based on the decontamination solution: NaCl 0.9% (control), Corega Tabs®, Periogard®, and 10% CA. The surface was characterized at baseline in terms of morphology, topography, and chemical and phase composition. Surface properties, including microhardness, wettability, and roughness, were assessed before and after exposure to each solution. Microbial viability, metabolic activity, and morphology of the polymicrobial biofilm were assessed after treatment to evaluate the efficacy of the decontamination solutions. Electrochemical and morphological evaluations were performed to assess the impact of each solution on the alloy’s corrosion process. No significant changes in microhardness were observed (p > 0.05). Decontamination solutions significantly increased surface hydrophilicity (p < 0.05) and roughness, though Ra values remained below the threshold for bacterial colonization. All denture cleansers significantly reduced biofilm viability compared to NaCl (p < 0.05), with no viable colonies post-treatment. The CA group showed a significant reduction in bacterial metabolic activity compared to NaCl and Periogard® (p < 0.05), indicating superior biofilm disruption. Electrochemical tests demonstrated that CA maintained a stable Cr-oxide passive layer, evidenced by nobler OCP values and lower icorr and corrosion rates compared to Periogard® (p < 0.05). SEM images revealed pitting corrosion in all groups, except CA. These findings suggest that CA is a promising and safer alternative for denture care, offering effective antimicrobial action while preserving the electrochemical integrity of Co-Cr alloys.


  • Open Access

    Navigating the Landscape of Periodontitis Nonsurgical Treatment: A Metatrend Study of The Scientific Production and Trends From 2001-2020

    by Victoria L Abdo, Caroline Dini, Maria Helena R Borges, Danilo V A P Domingues, Kamily A C C Sanchez, Rodrigo Martins, Belen Retamal-Valdes, Valentim A R Barão, Joāo Gabriel S Souza

    Nonsurgical therapies have been recommended and employed as a less invasive and cost-effective modality in managing periodontitis. In this context, different therapeutic protocols have been tested in the last decades. Therefore, mapping the scientific trends and patterns provides critical insights into the state of research in the field, which has not been explored for overall nonsurgical periodontitis treatment studies. Articles from 2001 to 2020 were retrieved from the Web of Science database using appropriate terms and keywords. Article selection and data extraction were performed by calibrated examiners. All articles focusing on nonsurgical periodontitis treatment were included. Descriptive, bivariate, and multivariate logistic regression analyses were conducted. 1,519 articles were included. Randomized clinical trials (RCTs) were the most used design (44.1%), and professional biofilm control was the topic most studied (35.6%). Europe published the most significant number of articles (41.1%). The USA was the country that collaborated more with other countries. Asia (p<0.001), South America (p=0.004), and Oceania/Africa (p=0.016) showed a lower chance to have international collaboration. Studies from North America were more likely to be RCTs than studies from Europe (p=0.050); studies focusing on professional biofilm control (p<0.001) and other topics (p<0.001) were less likely to be evaluated by RCTs. The nonsurgical periodontitis treatment field mainly conducted RCTs, and the topic most explored by all studies was professional biofilm control. International collaboration and conduct of RCTs in this field occurred mainly among high-income countries. Decentralizing scientific resources, making integrative connections globally, and evaluating new topics may improve evidence-based periodontology.


  • Open Access

    Evaluation of physical-mechanical properties of self-adhesive versus conventional resin cements

    by Maria Helena Rossy Borges, Carmen Gilda Tavares Dias, Cristiane de Melo Alencar, Cecy Martins Silva, Renata Antunes Esteves

    Aim: The purpose of this study was to compare the microhardness, diametral tensile strength, compressive strength and the rheological properties of self-adhesive versus conventional resin cements. Methods: Specimens of a conventional (RelyX ARC) and 3 self-adhesive (RelyX U200, Maxcem Elite, Bifix SE) types of resin cements were prepared. The Knoop test was used to assess the microhardness, using a Microhardness Tester FM 700. For the diametral tensile strength test, a tensile strength was applied at a speed of 0.6 mm/minute. A universal testing machine was used for the analysis of compressive strength and a thermo-controlled oscillating rheometer was used for the Rheology test. One-way ANOVA and Tukey’s test (α=0.05) were used for data analysis. Results: According to microhardness analysis, all the cements were statistically similar (p>0.05), except for Maxcem that presented lower hardness compared with the other cements in relation to the top surface (p0.05), presented higher value when compared to the Maxcem and Bifix cements (p<0.05). The compressive strength of RelyX ARC and Maxcem Elite cements was statistically higher than RelyX U200 and Bifix cements (p<0.05). Regarding the rheology test, Maxcem Elite and RelyX ARC cements showed a high modulus of elasticity. Conclusions: The self-adhesive cements presented poorer mechanical properties than conventional resin cement. Chemical structure and types of monomers employed interfere directly in the mechanical properties of resin cements.