Phung Tu
Phung Tu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Vanissorn Vimonsatit
School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia
4 shared publications - Chayanon Hansapinyo
Excellence Centre in Infrastructure Technology and Transportation Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand
2 shared publications - Chinnapat Buachart
Department of Civil Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand
1 shared publication - Jun Li
Centre for Infrastructural Monitoring and Protection, School of Civil and Mechanical Engineering, Curtin University, Kent Street, Bentley, WA 6102, Australia
1 shared publication - Panatchai Chetchotisak
Rajamangala University of Technology Isan
1 shared publication - Suchart Limkatanyu
Department of Civil and Environmental Engineering, Faculty of Engineering, Prince of Songkla University, Songkla 90110, Thailand
1 shared publication
Latest Publications
- 1 April 2026
- Published by Ital Publication in Civil Engineering Journal
- Vol. 12 (4) , 1334-1353
Evaluating Signal Processing Methods for Instantaneous Frequency Analysis in Time-Varying Mass Structures
Time-varying mass (TVM) structures exhibit complex dynamic phenomena but remain insufficiently investigated, particularly in the frequency domain. For example, granular discharge in silos generates vibrations due to rapid mass reduction, leading to nonlinear and non-stationary responses. This study aims to evaluate the capability of three common signal processing algorithms-Empirical Mode Decomposition (EMD), Variational Mode Decomposition (VMD), and Empirical Wavelet Transform (EWT)-for analysing instantaneous frequency variations in TVM structures. The signals are first decomposed into mono-component modes and subsequently analyzed using the Hilbert transform to extract instantaneous frequency. The investigation is conducted in two stages: (i) numerical validation using an artificial nonlinear signal and a time-varying parameter SDOF system with known frequency histories, and (ii) application to experimental acceleration data obtained from sand discharge in a polycarbonate silo under noisy conditions. The findings show that EMD provides the most accurate frequency estimation for clean signals, whereas VMD and EWT demonstrate improved stability for experimental data with significant noise. The study provides a systematic comparison of decomposition-based instantaneous frequency methods in TVM structures and highlights the importance of appropriate method selection for safer and more reliable frequency-domain structural design.
- 1 April 2026
- Published by Ital Publication in Civil Engineering Journal
- Vol. 12 (4) , 1334-1353
Evaluating Signal Processing Methods for Instantaneous Frequency Analysis in Time-Varying Mass Structures
Time-varying mass (TVM) structures exhibit complex dynamic phenomena but remain insufficiently investigated, particularly in the frequency domain. For example, granular discharge in silos generates vibrations due to rapid mass reduction, leading to nonlinear and non-stationary responses. This study aims to evaluate the capability of three common signal processing algorithms-Empirical Mode Decomposition (EMD), Variational Mode Decomposition (VMD), and Empirical Wavelet Transform (EWT)-for analysing instantaneous frequency variations in TVM structures. The signals are first decomposed into mono-component modes and subsequently analyzed using the Hilbert transform to extract instantaneous frequency. The investigation is conducted in two stages: (i) numerical validation using an artificial nonlinear signal and a time-varying parameter SDOF system with known frequency histories, and (ii) application to experimental acceleration data obtained from sand discharge in a polycarbonate silo under noisy conditions. The findings show that EMD provides the most accurate frequency estimation for clean signals, whereas VMD and EWT demonstrate improved stability for experimental data with significant noise. The study provides a systematic comparison of decomposition-based instantaneous frequency methods in TVM structures and highlights the importance of appropriate method selection for safer and more reliable frequency-domain structural design.
- Open Access
- 1 January 2023
- Published by Ital Publication in Civil Engineering Journal
- Vol. 9 (1) , 17-28
The Influence of Moisture on the Frequency Spectrum of Time Varying Mass Engineering Structure
The frequencies of time-varying mass systems have not been commonly studied in engineering structures as the rate of mass change is generally small compared to the mass of the overall structure. For silos of granular materials, the total mass of the stored granules can be relatively high compared to the mass of the silo structure. During the flow-in or flow-out of granules, the silo system behaves as a time-varying mass system. Minor changes to the moisture content ratio of the granules can cause their flow characteristics to change. The influence of the moisture content ratio of the granular material inside a cylindrical silo is investigated in this paper using Variational Mode Decomposition, Hilbert Transform, and Hilbert Marginal Spectrum processing methods. The results show that the amplitude and frequency of vibration vary with the change in the moisture content ratio of the stored materials and across different cycles, despite all influencing parameters being kept constant. Such variations in the response of the structure mean that the loads also vary according to the principles of engineering mechanics. The outcomes of this research can be further developed into a diagnostic tool to conditionally monitor the structural integrity of the overall silo structure and flow characteristics automatically. Doi: 10.28991/CEJ-2023-09-01-02 Full Text: PDF
- 1 January 2023
- Published by Ital Publication in Civil Engineering Journal
- Vol. 9 (1) , 17-28
Open AccessThe Influence of Moisture on the Frequency Spectrum of Time Varying Mass Engineering Structure
The frequencies of time-varying mass systems have not been commonly studied in engineering structures as the rate of mass change is generally small compared to the mass of the overall structure. For silos of granular materials, the total mass of the stored granules can be relatively high compared to the mass of the silo structure. During the flow-in or flow-out of granules, the silo system behaves as a time-varying mass system. Minor changes to the moisture content ratio of the granules can cause their flow characteristics to change. The influence of the moisture content ratio of the granular material inside a cylindrical silo is investigated in this paper using Variational Mode Decomposition, Hilbert Transform, and Hilbert Marginal Spectrum processing methods. The results show that the amplitude and frequency of vibration vary with the change in the moisture content ratio of the stored materials and across different cycles, despite all influencing parameters being kept constant. Such variations in the response of the structure mean that the loads also vary according to the principles of engineering mechanics. The outcomes of this research can be further developed into a diagnostic tool to conditionally monitor the structural integrity of the overall silo structure and flow characteristics automatically. Doi: 10.28991/CEJ-2023-09-01-02 Full Text: PDF
- Open Access
- 19 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5675
Comment on Maraveas, C. Concrete Silos: Failures, Design Issues and Repair/Strengthening Methods. Appl. Sci. 2020, 10, 3938
Current silo analysis and design methods developed from Janssen’s theory focus mainly on the flow of the granules inside the silo by assuming that the overall silo structure is infinitely rigid. A silo structure during discharge is technically a time varying mass dynamic problem, where the properties of the overall silo structure and the discharge rate and material properties also contribute to the development of the load. The physics of a silo system requires equilibrium between the granules inside the silo, the silo structure as a whole and the surrounding air. The established scientific principles and experimental data require fulfilling such equilibrium to accurately predict the dynamic loads during discharge. This correspondence explains how the equilibrium between the granules inside the silo, the silo structure as a whole and the surrounding air can be achieved to better predict and control the dynamic loads generated by the silo discharge process.
- 19 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5675
Open AccessComment on Maraveas, C. Concrete Silos: Failures, Design Issues and Repair/Strengthening Methods. Appl. Sci. 2020, 10, 3938
Current silo analysis and design methods developed from Janssen’s theory focus mainly on the flow of the granules inside the silo by assuming that the overall silo structure is infinitely rigid. A silo structure during discharge is technically a time varying mass dynamic problem, where the properties of the overall silo structure and the discharge rate and material properties also contribute to the development of the load. The physics of a silo system requires equilibrium between the granules inside the silo, the silo structure as a whole and the surrounding air. The established scientific principles and experimental data require fulfilling such equilibrium to accurately predict the dynamic loads during discharge. This correspondence explains how the equilibrium between the granules inside the silo, the silo structure as a whole and the surrounding air can be achieved to better predict and control the dynamic loads generated by the silo discharge process.
- 9 September 2020
- Published by Elsevier in Chemical Engineering Science
- Vol. 229, 116070
Comments on ‘A theory for pressures in cylindrical silos under concentric mixed flow’ (Chem. Eng. Sci., Vol. 223, 115748)
- 9 September 2020
- Published by Elsevier in Chemical Engineering Science
- Vol. 229, 116070
Comments on ‘A theory for pressures in cylindrical silos under concentric mixed flow’ (Chem. Eng. Sci., Vol. 223, 115748)
- 14 August 2018
- Published by Elsevier in Advanced Powder Technology
- Vol. 29 (11) , 2775-2784
Silo quake response spectrum of iron ore train load out bin
- 14 August 2018
- Published by Elsevier in Advanced Powder Technology
- Vol. 29 (11) , 2775-2784
Silo quake response spectrum of iron ore train load out bin