Clóvis Lamartine de Moraes Melo Neto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Clóvis Lamartine de Moraes Melo Neto has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Coelho Goiato
Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Sao Paulo State University (UNESP), Aracatuba, Sao Paulo, Brazil
27 shared publications Daniela Micheline dos Santos
Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Sao Paulo State University (UNESP), Aracatuba, Sao Paulo, Brazil
14 shared publications- Daniela Micheline dos Santos
Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Sao Paulo State University (UNESP), Aracatuba, Sao Paulo, Brazil
11 shared publications André Pinheiro de Magalhães Bertoz
Department of Pediatric and Social Dentistry, School of Dentistry São Paulo State University Araçatuba, São Paulo Brazil
8 shared publicationsEmily Vivianne Freitas da Silva
Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University (UNESP), Araçatuba, Brazil
6 shared publicationsAndré Luiz de Melo Moreno
Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, São Paulo, Brazil
5 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 15 (03) , 353-362
Effect of Cement, Implant Connection, and Aging on the Retention Strength of Zirconia Crowns to Ti-Base
Considering the increased use of digital workflows in restorative dentistry, abutments with computer-stored geometry aided by Computer-Aided Designing/Computer- Aided Manufacturing (CAD/CAM) technology systems for rapid restoration fabrication, also known as Ti-base abutments, have gained interest. This study aimed to evaluate the influence of the type of cement, aging, and implant connection on the retention of zirconia crowns cemented onto the Ti-base abutment. To accomplish this, the specimens were divided into four groups regarding implant connection and cement: Ti-base on External Hexagon (EH) connection (n= 20), Ti-base on Morse taper (MT) connection (n = 20), and temporary or definitive cement. All groups were evaluated with or without mechanical aging and underwent a tensile test to evaluate the retention strength. Data analysis was assessed using the Shapiro-Wilk, three-way analysis of variance (ANOVA) with repeated measures, and Tukey’s test (p < 0.05). The failure mode was also recorded. The MT connection presented a statistically significantly higher average retention strength than the EH connection. Groups with the definitive cement on MT connection presented the highest value compared with the temporary cement groups (565 N and 491 N, respectively). Most mixed failures were found for all groups. Overall, the mechanical aging reduced the retention strength of milled zirconia crowns cemented on Ti-base abutments. The definitive cement promoted higher retention strength on MT connection compared with EH.
- 27 April 2026
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 15 (03) , 353-362
Open AccessEffect of Cement, Implant Connection, and Aging on the Retention Strength of Zirconia Crowns to Ti-Base
Considering the increased use of digital workflows in restorative dentistry, abutments with computer-stored geometry aided by Computer-Aided Designing/Computer- Aided Manufacturing (CAD/CAM) technology systems for rapid restoration fabrication, also known as Ti-base abutments, have gained interest. This study aimed to evaluate the influence of the type of cement, aging, and implant connection on the retention of zirconia crowns cemented onto the Ti-base abutment. To accomplish this, the specimens were divided into four groups regarding implant connection and cement: Ti-base on External Hexagon (EH) connection (n= 20), Ti-base on Morse taper (MT) connection (n = 20), and temporary or definitive cement. All groups were evaluated with or without mechanical aging and underwent a tensile test to evaluate the retention strength. Data analysis was assessed using the Shapiro-Wilk, three-way analysis of variance (ANOVA) with repeated measures, and Tukey’s test (p < 0.05). The failure mode was also recorded. The MT connection presented a statistically significantly higher average retention strength than the EH connection. Groups with the definitive cement on MT connection presented the highest value compared with the temporary cement groups (565 N and 491 N, respectively). Most mixed failures were found for all groups. Overall, the mechanical aging reduced the retention strength of milled zirconia crowns cemented on Ti-base abutments. The definitive cement promoted higher retention strength on MT connection compared with EH.
- Open Access
- 31 March 2026
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
Influence of the Adhesives and Pigment on the Physical and Optical Properties of Acrylic Resin
Acrylic resin is widely used in manufacturing removable implant-supported prostheses. To evaluate the influence of pigment addition and the application of different adhesives (Equate, Fixodent, and Poligrip) on the physical and optical properties of thermopolymerizable acrylic resins. A total of 160 samples were prepared for each test group (dimensional stability, detail reproduction, color, roughness, and surface microhardness), where 80 samples of each size, with and without pigment addition, were divided into 16 subgroups, including a control group with equate fixative, Poligrip, and Fixodent, with n = 10 samples. The samples were stored in an oven at 37°C, immersed in distilled water, and the adhesives were reapplied every 3 days for 2 months. Dimensional stability showed a significant difference only for pigment before and after aging (p < 0.01). Detail reproduction remained unchanged, with grooves and angles preserved regardless of adhesive. Color change was significant for pigment (p < 0.01). Aging significantly affected the properties of control (p ≤ 0.041), Equate (p ≤ 0.038), and Fixodent (p ≤ 0.034) adhesives, regardless of pigment, whereas Poligrip showed significant changes only in pigmented samples (p = 0.021). Surface microhardness differed significantly only after aging (p < 0.001), independent of other factors. The addition or absence of pigment caused changes in physical and optical properties after 2 months of aging, except in detailed reproduction and with the application of adhesives.
- 31 March 2026
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
Open AccessInfluence of the Adhesives and Pigment on the Physical and Optical Properties of Acrylic Resin
Acrylic resin is widely used in manufacturing removable implant-supported prostheses. To evaluate the influence of pigment addition and the application of different adhesives (Equate, Fixodent, and Poligrip) on the physical and optical properties of thermopolymerizable acrylic resins. A total of 160 samples were prepared for each test group (dimensional stability, detail reproduction, color, roughness, and surface microhardness), where 80 samples of each size, with and without pigment addition, were divided into 16 subgroups, including a control group with equate fixative, Poligrip, and Fixodent, with n = 10 samples. The samples were stored in an oven at 37°C, immersed in distilled water, and the adhesives were reapplied every 3 days for 2 months. Dimensional stability showed a significant difference only for pigment before and after aging (p < 0.01). Detail reproduction remained unchanged, with grooves and angles preserved regardless of adhesive. Color change was significant for pigment (p < 0.01). Aging significantly affected the properties of control (p ≤ 0.041), Equate (p ≤ 0.038), and Fixodent (p ≤ 0.034) adhesives, regardless of pigment, whereas Poligrip showed significant changes only in pigmented samples (p = 0.021). Surface microhardness differed significantly only after aging (p < 0.001), independent of other factors. The addition or absence of pigment caused changes in physical and optical properties after 2 months of aging, except in detailed reproduction and with the application of adhesives.
- Open Access
- 17 March 2026
- Published by Charles University in Prague, Karolinum Press in Prague Medical Report
- Vol. 127 (1) , 34-38
Influence of Copper Tongue Scraper and Toothbrush on Morning Halitosis in Dentistry Students: A Brief Clinical Study
The objective was to evaluate the influence of two tongue cleaning methods (copper tongue scraper and toothbrush) on morning halitosis in dental students. Thirteen dental students were included. After training, the first participant took the halimeter home and used it for 6 days. On the first three days, halitosis was measured immediately after the participant woke up in the morning. The night before each of these first three days, before going to sleep, the participant cleaned their mouth with dental floss and a soft-bristled toothbrush. The individual’s same soft-bristled toothbrush was also used to brush his tongue. Only one halitosis measurement was taken per day and the value was recorded each day (toothbrush group). On the fourth, fifth and sixth day, the same process was carried out, but the night before measuring halitosis, a copper tongue scraper was used to clean the participants’ tongue. Only one halitosis measurement was taken per day and the value was recorded each day (tongue scraper group). Subsequently, for each participant, the highest halitosis value of the first three days (toothbrush group) was chosen, as well as the highest halitosis value of the last three days (tongue scraper group). The Wilcoxon test was used to compare the two groups (P<0.05). The halitosis value (median) in the toothbrush group was significantly higher than that in the tongue scraper group. Only the tongue scraper group showed a clinically acceptable halitosis value (imperceptible odour). Therefore, the copper tongue scraper is more recommended for cleaning the tongue.
- 17 March 2026
- Published by Charles University in Prague, Karolinum Press in Prague Medical Report
- Vol. 127 (1) , 34-38
Open AccessInfluence of Copper Tongue Scraper and Toothbrush on Morning Halitosis in Dentistry Students: A Brief Clinical Study
The objective was to evaluate the influence of two tongue cleaning methods (copper tongue scraper and toothbrush) on morning halitosis in dental students. Thirteen dental students were included. After training, the first participant took the halimeter home and used it for 6 days. On the first three days, halitosis was measured immediately after the participant woke up in the morning. The night before each of these first three days, before going to sleep, the participant cleaned their mouth with dental floss and a soft-bristled toothbrush. The individual’s same soft-bristled toothbrush was also used to brush his tongue. Only one halitosis measurement was taken per day and the value was recorded each day (toothbrush group). On the fourth, fifth and sixth day, the same process was carried out, but the night before measuring halitosis, a copper tongue scraper was used to clean the participants’ tongue. Only one halitosis measurement was taken per day and the value was recorded each day (tongue scraper group). Subsequently, for each participant, the highest halitosis value of the first three days (toothbrush group) was chosen, as well as the highest halitosis value of the last three days (tongue scraper group). The Wilcoxon test was used to compare the two groups (P<0.05). The halitosis value (median) in the toothbrush group was significantly higher than that in the tongue scraper group. Only the tongue scraper group showed a clinically acceptable halitosis value (imperceptible odour). Therefore, the copper tongue scraper is more recommended for cleaning the tongue.
- Open Access
- 25 January 2026
- Published by Georg Thieme Verlag KG in Brazilian Journal of Oncology
- Vol. 22 (CP)
Sensory Function in Patients with Head and Neck Cancer Undergoing Oncologic Treatment
The treatment of head and neck cancer can significantly impair patients' quality of life, leading to oral and sensorineural complications. This study aimed to explore whether sensory alterations are primarily associated with tumor presence or with the effects of oncologic treatment by longitudinally assessing spontaneous orofacial pain and provoked muscle pain - in a case series of seven patients diagnosed with head and neck cancer undergoing oncologic treatment. Patients were selected from the Oral Oncology Center (COB) of the School of Dentistry at Universidade Estadual Paulista “Júlio de Mesquita Filho”. Assessments were conducted at 5 time points: baseline (T0), 30 to 45 days post-surgery (T1), one-week post-chemotherapy (T2), during radiotherapy (T3), and one-week post-radiotherapy (T4). Sensory function was analyzed through spontaneous pain measured by the Numeric Rating Scale (NRS) from 0 to 10, and provoked pain assessed via palpometry using 1 kg pressure and algometry tests on the masseter, temporalis, and sternocleidomastoid muscles. Only one patient (case 1) reported pain at T0, while two patients (cases 3 and 4) reported pain related to radiotherapy. Provoked muscle pain was highest at T0, particularly in cases 1, 4, and 7, but did not correlate with algometry pain thresholds. This case series indicates that sensory function may be affected by both tumor presence and oncologic treatment in a subset of patients.
- 25 January 2026
- Published by Georg Thieme Verlag KG in Brazilian Journal of Oncology
- Vol. 22 (CP)
Open AccessSensory Function in Patients with Head and Neck Cancer Undergoing Oncologic Treatment
The treatment of head and neck cancer can significantly impair patients' quality of life, leading to oral and sensorineural complications. This study aimed to explore whether sensory alterations are primarily associated with tumor presence or with the effects of oncologic treatment by longitudinally assessing spontaneous orofacial pain and provoked muscle pain - in a case series of seven patients diagnosed with head and neck cancer undergoing oncologic treatment. Patients were selected from the Oral Oncology Center (COB) of the School of Dentistry at Universidade Estadual Paulista “Júlio de Mesquita Filho”. Assessments were conducted at 5 time points: baseline (T0), 30 to 45 days post-surgery (T1), one-week post-chemotherapy (T2), during radiotherapy (T3), and one-week post-radiotherapy (T4). Sensory function was analyzed through spontaneous pain measured by the Numeric Rating Scale (NRS) from 0 to 10, and provoked pain assessed via palpometry using 1 kg pressure and algometry tests on the masseter, temporalis, and sternocleidomastoid muscles. Only one patient (case 1) reported pain at T0, while two patients (cases 3 and 4) reported pain related to radiotherapy. Provoked muscle pain was highest at T0, particularly in cases 1, 4, and 7, but did not correlate with algometry pain thresholds. This case series indicates that sensory function may be affected by both tumor presence and oncologic treatment in a subset of patients.
- 14 May 2025
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 29 (1) , 1-10
Impact of buccal fat pad removal on electrical activity of masseter, temporal, and buccinator muscles, anxiety, aesthetic satisfaction, and quality of life
Purpose To evaluate the electromyographic activity of the masseter, temporal, and buccinator muscles, as well as anxiety levels, aesthetic satisfaction, and quality of life following bichectomy. Methods Nine patients were included. Electromyography of the masseter, anterior temporal, and buccinator muscles was performed, along with assessment of the number of masticatory cycles and mastication time until swallowing. Anxiety levels (Generalized Anxiety Disorder-7), the impact of surgery on quality of life (Glasgow Benefit Inventory - GBI), and patient aesthetic satisfaction were evaluated using questionnaires. Assessments were conducted before surgery (T0), 60 days after surgery (T1), and 120 days after surgery (T2). A 2-way repeated measures ANOVA was used and when the analyzed data were not considered normal, the Friedman test was used (p < 0.05). Results The activity of the masseter and buccinator muscles increased significantly after 30 days (T1) and 120 days (T2) after bichectomy compared to T0. The number of chewing cycles and time until swallowing and anxiety did not change significantly over time. Aesthetic satisfaction increased significantly after 30 days. Conclusion Removing the main body of the Bichat ball increased the electrical activity of the masseter and buccinator muscles during chewing of the tested foods. The participants’ anxiety level over time was considered clinically acceptable. Buccal fat pad removal did not influence the number of chewing cycles and chewing time until swallowing. Aesthetic satisfaction increased 60 days after bichectomy. After 120 days of buccal fat pad removal, there was an improvement in the quality of life of the individuals.
- 14 May 2025
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 29 (1) , 1-10
Impact of buccal fat pad removal on electrical activity of masseter, temporal, and buccinator muscles, anxiety, aesthetic satisfaction, and quality of life
Purpose To evaluate the electromyographic activity of the masseter, temporal, and buccinator muscles, as well as anxiety levels, aesthetic satisfaction, and quality of life following bichectomy. Methods Nine patients were included. Electromyography of the masseter, anterior temporal, and buccinator muscles was performed, along with assessment of the number of masticatory cycles and mastication time until swallowing. Anxiety levels (Generalized Anxiety Disorder-7), the impact of surgery on quality of life (Glasgow Benefit Inventory - GBI), and patient aesthetic satisfaction were evaluated using questionnaires. Assessments were conducted before surgery (T0), 60 days after surgery (T1), and 120 days after surgery (T2). A 2-way repeated measures ANOVA was used and when the analyzed data were not considered normal, the Friedman test was used (p < 0.05). Results The activity of the masseter and buccinator muscles increased significantly after 30 days (T1) and 120 days (T2) after bichectomy compared to T0. The number of chewing cycles and time until swallowing and anxiety did not change significantly over time. Aesthetic satisfaction increased significantly after 30 days. Conclusion Removing the main body of the Bichat ball increased the electrical activity of the masseter and buccinator muscles during chewing of the tested foods. The participants’ anxiety level over time was considered clinically acceptable. Buccal fat pad removal did not influence the number of chewing cycles and chewing time until swallowing. Aesthetic satisfaction increased 60 days after bichectomy. After 120 days of buccal fat pad removal, there was an improvement in the quality of life of the individuals.
- Open Access
- 25 April 2025
- Published by MDPI AG in Preprints.org
Effect of Cement, Implant Connection, and Aging on the Retention Strength of Zirconia Crowns to Ti-Base
Purpose: To analyze the influence of the type of cement, aging, and implant connection regarding the Institute of Excellence in Teaching and Research-IETR Institute of Excellence in Teaching and Research-IETR retention capacity of zirconia crowns cemented onto the Titanium base abutment Material and methods: The specimens was divided into four groups: Ti-Base External Hexagon 5,0x4,7x1,0 mm (n=20) or Ti-Base Morse Taper 5,0x4,7x1,5 mm (n=20), temporary or definitive cement, and mechanical aging (with or without). All the samples underwent a tensile test. Results: Data analysis was assessed using the Shapiro-Wilk, three-way ANOVA with repeated measures, and Tukey's test (P < 0.05). The failure mode was also recorded. The Morse taper implants presented a statisti-cally significantly higher average retention strength than the external hexagon implants. Groups III and IV presented the highest value compared to the other groups (565 and 491 N). Most mixed failures were found for all groups. Conclusion: Mechanical aging imped-ed the retention force of milled zirconia crowns cemented on titanium base abutments with resin cement on Morse taper implants had greater retention force compared to exter-nal hexagon implants.
- 25 April 2025
- Published by MDPI AG in Preprints.org
Open AccessEffect of Cement, Implant Connection, and Aging on the Retention Strength of Zirconia Crowns to Ti-Base
Purpose: To analyze the influence of the type of cement, aging, and implant connection regarding the Institute of Excellence in Teaching and Research-IETR Institute of Excellence in Teaching and Research-IETR retention capacity of zirconia crowns cemented onto the Titanium base abutment Material and methods: The specimens was divided into four groups: Ti-Base External Hexagon 5,0x4,7x1,0 mm (n=20) or Ti-Base Morse Taper 5,0x4,7x1,5 mm (n=20), temporary or definitive cement, and mechanical aging (with or without). All the samples underwent a tensile test. Results: Data analysis was assessed using the Shapiro-Wilk, three-way ANOVA with repeated measures, and Tukey's test (P < 0.05). The failure mode was also recorded. The Morse taper implants presented a statisti-cally significantly higher average retention strength than the external hexagon implants. Groups III and IV presented the highest value compared to the other groups (565 and 491 N). Most mixed failures were found for all groups. Conclusion: Mechanical aging imped-ed the retention force of milled zirconia crowns cemented on titanium base abutments with resin cement on Morse taper implants had greater retention force compared to exter-nal hexagon implants.
- Open Access
- 12 December 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 27 (1) , 34-42
Intraoral and Extraoral Scanning Technologies in the Digital Workflow Era: An Integrative Review with Artificial Intelligence
The aim of this integrative review is to investigate the possibility of aligning three-dimensional intraoral scanner data with facial mobile device data, as well as comparing the effectiveness of AI-based search with manual search methods. This investigation adhered to the PRISMA guidelines aiming to answer the PICO question: “Does the facial and intraoral three-dimensional technologies are compatible and clinically applicable in oral rehabilitation?”. Was employed a search strategy incorporating specific keywords ("dental", "intraoral", "photogrammetry", "stereo photo", "scanner", "three-dimensional", "stereophotogrammetry", "scan", "virtual articulators", "facebow", "face", "facial") within multiple databases (Pubmed, BVS, and Scielo), including artificial intelligence (Scite.ai). Of the 7128 initially identified articles, 4 articles of manual search were included but none article of the artificial intelligence website were added. Among the most used: at the intraoral scanners were the TRIOS (3shape) (n=2) and for facial images the Apple Inc. cell phones (n=2). The most frequently reported software was Bellus3D (Bellus3D Inc.) with particular emphasis on the georeferencing tactic software. Several commonalities were observed, including the requirement for a 30cm spacing during cell phone-based extraoral scanning, the necessity for multiple captures, and the inclusion of landmarks and/or perioral and nasal scans. Manual searching is still the gold standard scientific searching data; Both stereophotogrammetry and mobile device scan can be used for facial scanning and the files can be integrated by utilizing georeferencing tactic software.
- 12 December 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 27 (1) , 34-42
Open AccessIntraoral and Extraoral Scanning Technologies in the Digital Workflow Era: An Integrative Review with Artificial Intelligence
The aim of this integrative review is to investigate the possibility of aligning three-dimensional intraoral scanner data with facial mobile device data, as well as comparing the effectiveness of AI-based search with manual search methods. This investigation adhered to the PRISMA guidelines aiming to answer the PICO question: “Does the facial and intraoral three-dimensional technologies are compatible and clinically applicable in oral rehabilitation?”. Was employed a search strategy incorporating specific keywords ("dental", "intraoral", "photogrammetry", "stereo photo", "scanner", "three-dimensional", "stereophotogrammetry", "scan", "virtual articulators", "facebow", "face", "facial") within multiple databases (Pubmed, BVS, and Scielo), including artificial intelligence (Scite.ai). Of the 7128 initially identified articles, 4 articles of manual search were included but none article of the artificial intelligence website were added. Among the most used: at the intraoral scanners were the TRIOS (3shape) (n=2) and for facial images the Apple Inc. cell phones (n=2). The most frequently reported software was Bellus3D (Bellus3D Inc.) with particular emphasis on the georeferencing tactic software. Several commonalities were observed, including the requirement for a 30cm spacing during cell phone-based extraoral scanning, the necessity for multiple captures, and the inclusion of landmarks and/or perioral and nasal scans. Manual searching is still the gold standard scientific searching data; Both stereophotogrammetry and mobile device scan can be used for facial scanning and the files can be integrated by utilizing georeferencing tactic software.
- Open Access
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (01) , 007-014
What Is the Survival Rate of Implants Loaded Immediately with a Branemark Protocol Prosthesis? A Review
The aim of this review was to determine the survival rate of implants loaded immediately with a Branemark protocol prosthesis. An electronic search was performed in the PubMed/MEDLINE database from 2006 to February 2024, using a combination of Medical Subject Headings descriptors: “completely edentulous” and “immediate loading.” Human clinical articles in English that evaluated the survival rate of implants loaded immediately with a Branemark protocol prosthesis after placement in the bone were included. A total of 546 articles were identified, of which 15 were included in this study. The 15 articles included in the literature showed a high implant survival rate (more than 93%) after immediate loading.
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (01) , 007-014
Open AccessWhat Is the Survival Rate of Implants Loaded Immediately with a Branemark Protocol Prosthesis? A Review
The aim of this review was to determine the survival rate of implants loaded immediately with a Branemark protocol prosthesis. An electronic search was performed in the PubMed/MEDLINE database from 2006 to February 2024, using a combination of Medical Subject Headings descriptors: “completely edentulous” and “immediate loading.” Human clinical articles in English that evaluated the survival rate of implants loaded immediately with a Branemark protocol prosthesis after placement in the bone were included. A total of 546 articles were identified, of which 15 were included in this study. The 15 articles included in the literature showed a high implant survival rate (more than 93%) after immediate loading.
- Open Access
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (01) , 180-186
Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants
Objective The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical–buccal areas around these types of implants. Materials and Methods This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant (3.75 × 11.5 mm) in the area of artificial tooth 15. The strain gauges were glued to the mesial, distal, and apical–buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken. Statistical Analysis Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with “implant connection” and “strain gauge position” factors, followed by the Bonferroni test (p < 0.05). Results The MT group showed significantly lower microstrain values in the mesial and apical strain gauges compared to the EH group. Conclusion The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (01) , 180-186
Open AccessEvaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants
Objective The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical–buccal areas around these types of implants. Materials and Methods This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant (3.75 × 11.5 mm) in the area of artificial tooth 15. The strain gauges were glued to the mesial, distal, and apical–buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken. Statistical Analysis Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with “implant connection” and “strain gauge position” factors, followed by the Bonferroni test (p < 0.05). Results The MT group showed significantly lower microstrain values in the mesial and apical strain gauges compared to the EH group. Conclusion The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.
- Open Access
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 18 (04) , 971-975
The Influence of Genetics and Gene Polymorphism on Biological Complications for Dental Implant Survival: A Review
The objective of this review is to expose the main genetic changes and genetic polymorphisms that may or may not be associated with greater susceptibility to reduced survival of dental implants and, consequently, to their loss. Case–control studies that fully portrayed the specific types of genetic polymorphisms that may be associated with dental implant failure were included by searching in the PubMed, Scopus, and Web of Science databases from 2010 to 2023. The following descriptors and their combinations in English were used to search for articles: “dental implants,” “bone genes,” “genetics,” “polymorphism genetics,” “genetic risk factor,” and “interleukin.” The initial search resulted in 107 results (PubMed n = 47, Scopus n = 14, and Web of Science n = 46). After a manual search, reviewing each article's title and abstract, and excluding duplicates, systematic reviews, and literature reviews, 30 articles were selected. After reading these 30 articles in full, 18 studies that did not describe the specific genetic polymorphism in relation to dental implant survival were excluded. Therefore, 12 articles were included in this review. The genetic polymorphisms of interleukin (IL)-1A, IL-1B, IL-4, IL-6, IL-10, IL-1 receptor antagonist, tumor necrosis factor-α, receptor activator of nuclear factor kappa B legend, and cluster of differentiation 14 were analyzed in the included studies. In seven of the studies, a statistically significant correlation between genetic polymorphisms and dental implant failure was observed. Of the polymorphisms studied, IL-1A (−899), IL-1B (+3954), and IL-4 (+33) showed a greater association with dental implant loss.
- 16 July 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 18 (04) , 971-975
Open AccessThe Influence of Genetics and Gene Polymorphism on Biological Complications for Dental Implant Survival: A Review
The objective of this review is to expose the main genetic changes and genetic polymorphisms that may or may not be associated with greater susceptibility to reduced survival of dental implants and, consequently, to their loss. Case–control studies that fully portrayed the specific types of genetic polymorphisms that may be associated with dental implant failure were included by searching in the PubMed, Scopus, and Web of Science databases from 2010 to 2023. The following descriptors and their combinations in English were used to search for articles: “dental implants,” “bone genes,” “genetics,” “polymorphism genetics,” “genetic risk factor,” and “interleukin.” The initial search resulted in 107 results (PubMed n = 47, Scopus n = 14, and Web of Science n = 46). After a manual search, reviewing each article's title and abstract, and excluding duplicates, systematic reviews, and literature reviews, 30 articles were selected. After reading these 30 articles in full, 18 studies that did not describe the specific genetic polymorphism in relation to dental implant survival were excluded. Therefore, 12 articles were included in this review. The genetic polymorphisms of interleukin (IL)-1A, IL-1B, IL-4, IL-6, IL-10, IL-1 receptor antagonist, tumor necrosis factor-α, receptor activator of nuclear factor kappa B legend, and cluster of differentiation 14 were analyzed in the included studies. In seven of the studies, a statistically significant correlation between genetic polymorphisms and dental implant failure was observed. Of the polymorphisms studied, IL-1A (−899), IL-1B (+3954), and IL-4 (+33) showed a greater association with dental implant loss.