DADemet Altunbaş

Demet Altunbaş

*This is an algorithmically generated author record based on publicly available information.

Demet Altunbaş has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of Residual Root Canal Sealer Removal Efficacy of Different Irrigation Activation Techniques by Confocal Laser Microscopy Analysis

    by Zeliha Uğur Aydin, Demet Altunbaş, Sevim Koşumcu, Büşra Meşeci̇, Tülin Doğan

    Objective: The purpose of this study was to use confocal laser microscopy analysis to evaluate the effectiveness of conventional needle irrigation (CNI), EndoActivator (EA), and EDDY during endodontic retreatment. Methods: This study included 45 maxillary incisor teeth with a single root and canal. Root canals were prepared with ProTaper Universal files (Dentsply Sirona, Ballaigues, Switzerland) and obturated with labeled sealer mixed with 0.1% Rhodamine B and gutta percha according to single cone techniques. Initial root canal filling material was removed using ProTaper Universal Retreatment files and F4 files. Teeth randomly were divided into 3 groups (n = 15) depending on the activation technique: CNI, EA (Dentsply, Tulsa Dental Specialties, Tulsa, OK), and EDDY (VDW, Munich, Germany). Confocal laser microscopy was used to evaluate the penetration area, depth, and percentage of the residual sealer in the apical, middle, and coronal sections after irrigation activation. Results: In all sections, the EDDY group had a lower penetration area of residual sealer than the CNI group (P< .05). In comparison to the coronal section, the penetration percentage of the CNI and EA groups was lower in the apical section (P< .05). In the CNI group, the penetration depth was higher at the coronal section than at the apical and middle sections (P< .05), and it was higher at the coronal section than at the apical section. Conclusion: Within the limitations of this study, none of the activation systems tested could completely remove the residual sealer. However, the lowest residual sealer was seen after using EA and EDDY.


  • Open Access

    Evaluation of Postoperative Pain Relief after Pulpotomy using Different Procedures for Disinfection and Hemostasis in Symptomatic Irreversible Pulpitis

    by D Altunbaş, M Ayhan, Ö Bilgin

    Aim: This study aimed to evaluate postoperative pain scores after sodium hypochlorite (NaOCl) and KTP laser pulpotomies in the permanent teeth with symptomatic irreversible pulpitis retrospectively. Materials and Methods: This study is based on the records of patients treated with pulpotomy using sodium hypochlorite or KTP laser for disinfection and hemostasis at the Department of Endodontics. Sixty patients’ molar teeth were treated with either NaOCl or KTP laser. Sodium hypochlorite was used on 31 teeth, and KTP laser was used on another 29 teeth, for disinfection and hemostasis. Initial bleeding control was obtained with saline. 2.5% NaOCl or KTP laser was applied to complete hemostasis. Calcium hydroxide was then placed on the chamber floor to cover the canal orifices. The permanent restoration was completed with composite resin. Pre and postoperative pain scores were recorded with a visual analog scale. The evaluation was performed on the 6th, 24th, 48th, 72nd hours, and 7th days depending on the severity of the pain. Results: There was no significant difference between the groups in terms of demographic data and preoperative pain scores (P > 0.05). The postoperative pain score in the KTP laser group was significantly lower at the 24th hour than in the NaOCl group (P < 0.05). No significant difference was found between the groups at other evaluated time intervals (P > 0.05). The greatest pain score was recorded at the 6th hour in both groups. Conclusion: Although the level of pain decreased significantly in both groups in the postoperative period, KTP laser-assisted pulpotomy provided better pain control, especially at the 24th hour.


  • Open Access

    The Roughening Effects of Er:YAG, Nd:YAG and KTP Laser Systems on Root Dentin Surface

    by Recai Zan, Hüseyin Topçuoğlu, İhsan Hubbezoğlu, Demet Altunbaş, Arzu Şeyma Demi̇r

    Objectives: Present study aimed to evaluate the roughening ability of different laser systems on the middle and apical third of roots. Materials and Methods: Sixty extracted human single-rooted single canal mandibular premolar teeth were randomly assigned to 3 groups (n=20). Standardized preparation and sterilization procedures were performed. The samples were irradiated with Er:YAG, Nd:YAG, and KTP laser systems. The laser irradiations (1.5 Watt) were applied with a spiral motion, starting 1 mm short of the apex and then moving coronally for 10 sec, interleaved with 15-sec recovery intervals for each irradiation. This process was repeated twelve times. The roots that were standardized in the same length and thicknesses were divided parallel to the longitudinal axis. Then, the middle and apical 1/3 surface roughness values of each root section were measured using a profilometer and SEM analysis was performed. The data obtained were analyzed using the two-way analysis of variance (ANOVA) and Tukey post-hoc tests. Results: According to measurements obtained from middle and apical 1/3 surfaces; Although, the statistically highest roughness value was determined after Nd:YAG laser (P < 0.05), the statistically lowest value was detected following the Er:YAG laser irradiation (P < 0.05). Conclusions: In light of the present study, all laser systems caused significant roughness surface. Therefore, laser systems should be carefully applied in human root canals.


  • Open Access

    Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals

    by Ömer Bi̇lgi̇n, Demet Altunbaş

    Objectives: The aim of this study was to compare the simulated canal shaping efficiencies of five different NiTi rotary file systems. Materials and Methods: In the study, 100 transparent resin blocks with J-shaped canals were randomly divided into five groups (n=20). Simulated canals were shaped with VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF), or ProTaper Next (PTN) files. Ten measuring points were detected on the pre- and post-preparation images taken from the blocks and superimposed. After preparation, the total canal width and the amount of transportation were calculated for the determined measuring levels. Zipping and ledge formation, instrument fracture and deformation, and change in working length were evaluated. The data were statistically analyzed with the Kolmogorov-Smirnov test, one-way ANOVA, Tukey test, Chi-Square test, and a Monte Carlo version of the Fisher Exact tests. The error level was taken as 0.05. Results: There were significant differences between the groups at all measuring levels in terms of total canal width after instrumentation (p = 0.001). Significant differences in the amount of transportation were found between the groups (p = 0.001) except at levels 4 (p = 0.169) and 10 (p = 0.054). Zip and instrument fractures did not occur in any group. 3 EF size 25/.04 files were deformed (p = 0.021). There was no significant difference between the groups in terms of ledge formation and working length change (p > 0.05). Conclusions: According to findings obtained in the study, transportation occurred at all 10 measuring levels with all file systems used. HF and EF systems were found to be more reliable in terms of transportation in the middle and coronal regions. Wider canal preparation was obtained with the PTN system in the middle and coronal regions.


  • Enstrümantasyon sırasında seçilen farklı tork ayarlarının endodontik tedavi görmüş dişlerin kırılma dayanımına etkisi

    by Demet Altunbaş, Eda Gürsu

    Background: The study evaluated the effect of root canal instrumentation at low and high torque settings on the fracture strength of endodontically treated teeth. Methods: Ninety extracted single-rooted human mandibular incisors were randomly divided into one control (CG) and two experimental groups (n=30): no instrumentation or filling (CG), instrumentation with ProTaper Universal files at low torque settings, and instrumentation with ProTaper Universal files at high torque settings. Root canal filling was performed with an epoxy resin-based sealer and gutta-percha using a single-cone technique in the experimental groups. Each specimen was tested for fracture strength. The analysis of variance and Tukey test were used to analyze the obtained data. The significance level was set at 0.05. Results: Statistically significant differences were observed between the groups (p = 0.001). While the difference between the CG and low torque groups was not significant (p > 0.05), the difference between the CG and high torque, low and high torque groups was significant (p < 0.05). Conclusion: According to this study results, since the lowest fracture strength value was observed in the high torque group, clinicians may be advised to choose the lowest torque settings recommended by the manufacturers for rotary systems.


  • MICRO-COMPUTED TOMOGRAPHIC EVALUATION OF DENTINAL CRACKS CAUSED BY VARIOUS RECENT FILE SYSTEMS

    by Recai Zan, Demet Altunbaş, İhSan Hubbezoğlu, Hüseyin Topçuoğlu, Gizem Kutlu Cengi̇z

    Objectives: The purpose of present study was to evaluate the incidence of dentinal micro-cracks observed after the use of ProTaper Gold (PTG), WaveOne Gold (WOG), OneShape New Generation (OSNG), K3XF nickel-titanium (NiTi) instrumentation systems. Materials and Methods: Sixty extracted human mandibular first molars were randomly assigned to four groups (n = 15). The root canals were instrumented with PTG, WOG, OSNG, and K3XF systems. The cross-sectional images of the roots were screened using high-resolution micro-computed tomography imaging before and after preparation to detect the presence of dentinal cracks. Results: Although there was no statistically significant difference between PTG and WOG systems, WOG caused lesser micro-crack among all groups. K3XF showed statistically fewer cracks than OSNG. K3XF and OSNG systems caused statistically more dentinal micro-cracks than both Gold systems. WOG and PTG systems caused lesser micro-cracks formation among the systems evaluated in present study. Both Gold systems may be preferred as safer to minimize micro-cracks during root canal treatments. Conclusions: All used systems have caused different degrees of crack formations. Furthermore, WOG and PTG systems have shown superior features in terms of creating dentinal cracks according to OSNG, and K3XF systems.

  • ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY

    by Demet Altunbaş, Kerem Engin Akpinar, Fatma Kaya

    Aim: The accuracy of three electronic apex locators (EALs) during retreatment of root-end resected teeth with different resection bevel angles were evaluated in the present study. Materials and Methods: Forty mandibular premolar teeth were divided into two groups regarding resection bevel angle after root canal filling. In the first group, the apical 3 mm of each specimen was resected at a 0-degree bevel angle using a diamond bur. The resection bevel angle was approximately 45-degree in the second group. Electronic length measurements were obtained with a size 15 K-file advanced apically in dissolved gutta percha using Dentaport ZX, Propex Pixi, and Apit 15. The filling materials were then completely removed from the root canals, and the actual lengths up to the resection region were determined. The actual length was subtracted from the electronic length measurements for each specimen. Measurements were analyzed statistically using independent sample t-test, repeated-measures analysis of variance, and Bonferroni tests. The level of statistical significance was defined as P<0.05. Results: In the 45-degree group, a significant difference was found between Propex Pixi and Apit 15. Measurements at 0- and 45-degree resection bevel angles were not statistically different from each other in any EAL groups. Conclusions: The resection bevel angle did not affect the accuracy of the tested EALs. More accurate measurements were obtained with the Propex Pixi at a 45-degree resection bevel angle compared with the Apit 15.


  • Evaluation of the effect of calcium hydroxide paste on sealer penetration into dentinal tubules by confocal laser scanning microscopy

    by Fatma Kanmaz, Demet Altunbaş

    The study evaluated sealer penetration after calcium hydroxide (Ca(OH)2) removal from the root canals. Sixty single‐rooted mandibular premolars were divided into six groups. Ca(OH)2 paste placed into the root canals except for the control group (CG) was removed using the following irrigation techniques: conventional needle irrigation (CNI), EndoActivator (EA), EndoVac (EV), passive ultrasonic irrigation (PUI) and photon‐induced photoacoustic streaming (PIPS) technique. After canal filling, the penetration depth, penetration area and penetration percentage of the sealer were determined using confocal microscopy. The CG and EA had a greater penetration depth than CNI in the middle section. The CG exhibited a higher dentinal tubule penetration area than CNI, EV and PUI in the middle section. EA was significantly more effective than PUI in the coronal section for the percentage of sealer penetration. EA and PIPS removed Ca(OH)2 from root canals effectively because they presented similar penetration to the CG in all sections.


  • The effect of various canal contents on the accuracy of two electronic apex locators in detecting different size of root perforations

    by Tülin Doğan, Zeliha Uğur Aydin, Demet Altunbaş

    Objective: This study was to investigate the effect of different canal contents on the accuracy of Gold Reciproc Motor (GRM; VDW, Munich, Germany) and DentaPort ZX (Morita Co, Kyoto, Japan) in the determination of artificial root perforations. Methods: Forty mandibular premolar teeth were included in this study. The crowns of the teeth were removed and the root lengths were standardized to be 14 +/- 1 mm. Roots were divided into 2 groups (n=20). Artificial root perforations were created 0.5 +/- 0.1mm and 1 +/- 0.1 mm in size respectively. The actual lengths (AL) up to the perforation areas were measured under the stereomicroscope. Electronic measurements (EL) were obtained by GRM and DentaPort ZX in dry conditions and the presence of NaOCl (5.25%), EDTA (17%) and blood. The difference was calculated by subtracting the ALs from the ELs. This difference was positive when the measurement was longer than the AL and negative when the measurement was shorter. The Friedman and Wilcoxon signed-rank tests were used to analyze the data (p<0.05). Results: There were no significant differences amongst the different intracanal conditions for both apex locators in teeth with perforation of 1 mm. In the teeth with a perforation of 0.5 mm DentaPort ZX measurements were not affected by intracanal conditions and the most accurate measurement was obtained when the canal was dry with GRM. Conclusion: Within the limitation of this study, intracanal conditions did not affect the measurements of DentaPort ZX in both perforation sizes, whereas in 0.5 mm perforation size, GRM measurements were affected by intracanal conditions..