Mareike Thies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mareike Thies has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Maier
Friedrich-Alexander-Universität Erlangen-Nürnberg, Pattern Recognition Lab, Erlangen, Germany
16 shared publications Mingxuan Gu
9 shared publicationsAndreas Maier
8 shared publicationsFabian Wagner
Friedrich-Alexander University Erlangen-Nuremberg, Pattern Recognition Lab, Erlangen, Germany
8 shared publications- Siyuan Mei
Pattern Recognition Lab, FAU Erlangen-Nürnberg
8 shared publications - Yipeng Sun
Friedrich-Alexander-Universität Erlangen-Nürnberg, Pattern Recognition Lab, Erlangen, Germany
7 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by Elsevier in Pattern Recognition
- Vol. 179
Vision transformer Hook for dense predictions
- 27 April 2026
- Published by Elsevier in Pattern Recognition
- Vol. 179
Open AccessVision transformer Hook for dense predictions
- 1 February 2026
- Published by Machine Learning for Biomedical Imaging in Machine Learning for Biomedical Imaging
- Vol. 2026 (MELBA–BVM ) , 284-296
Robustness and Stability Analysis of Differentiable Shift-Variant FBP for Cone-Beam CT under Challenging Acquisition Settings
The differentiable shift-variant filtered backprojection (SV-FBP) framework enables data-driven estimation of redundancy weights for cone-beam CT reconstruction under general source trajectories, removing the need for analytically derived weighting schemes. In this work, we present a systematic study of the robustness and adaptability of differentiable SV-FBP under challenging acquisition settings. We show that the framework remains stable across highly irregular and discontinuous trajectories, indicating that reconstruction performance is largely insensitive to trajectory ordering or continuity. Instead, the spatial distribution of sampling points plays a more dominant role. Under sparse-view conditions, differentiable SV-FBP achieves competitive reconstruction quality while providing an order-of-magnitude reduction in computation time compared to iterative reconstruction methods at moderate sampling densities. However, we identify a clear transition regime under severe undersampling, where the absence of iterative data consistency leads to performance degradation. Furthermore, we demonstrate that the framework remains applicable to non-planar multi-isocenter geometries, such as Lissajous-saddle trajectories, without requiring architectural modifications. These findings provide new insights into the behavior and limitations of the differentiable SV-FBP model and highlight it as a flexible and efficient solution for non-standard and robotic CBCT acquisition scenarios.
- 1 February 2026
- Published by Machine Learning for Biomedical Imaging in Machine Learning for Biomedical Imaging
- Vol. 2026 (MELBA–BVM ) , 284-296
Robustness and Stability Analysis of Differentiable Shift-Variant FBP for Cone-Beam CT under Challenging Acquisition Settings
The differentiable shift-variant filtered backprojection (SV-FBP) framework enables data-driven estimation of redundancy weights for cone-beam CT reconstruction under general source trajectories, removing the need for analytically derived weighting schemes. In this work, we present a systematic study of the robustness and adaptability of differentiable SV-FBP under challenging acquisition settings. We show that the framework remains stable across highly irregular and discontinuous trajectories, indicating that reconstruction performance is largely insensitive to trajectory ordering or continuity. Instead, the spatial distribution of sampling points plays a more dominant role. Under sparse-view conditions, differentiable SV-FBP achieves competitive reconstruction quality while providing an order-of-magnitude reduction in computation time compared to iterative reconstruction methods at moderate sampling densities. However, we identify a clear transition regime under severe undersampling, where the absence of iterative data consistency leads to performance degradation. Furthermore, we demonstrate that the framework remains applicable to non-planar multi-isocenter geometries, such as Lissajous-saddle trajectories, without requiring architectural modifications. These findings provide new insights into the behavior and limitations of the differentiable SV-FBP model and highlight it as a flexible and efficient solution for non-standard and robotic CBCT acquisition scenarios.
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (05) , 054004-13
BigReg: an efficient registration pipeline for high-resolution X-ray and light-sheet fluorescence microscopy
PurposeWe aim to propose a reliable registration pipeline tailored for multimodal mouse bone imaging using X-ray microscopy (XRM) and light-sheet fluorescence microscopy (LSFM). These imaging modalities have emerged as pivotal tools in preclinical research, particularly for studying bone remodeling diseases such as osteoporosis. Although multimodal registration enables micrometer-level structural correspondence and facilitates functional analysis, conventional landmark-, feature-, or intensity-based approaches are often infeasible due to inconsistent signal characteristics and significant misalignment resulting from independent scanning, especially in real-world and reference-free scenarios.ApproachTo address these challenges, we introduce BigReg, an automatic, two-stage registration pipeline optimized for high-resolution XRM and LSFM volumes. The first stage involves extracting surface features and applying two successive global-to-local point-cloud-based methods for coarse alignment. The subsequent stage refines this alignment in the 3D Fourier domain using a modified cross-correlation technique, achieving precise volumetric registration.ResultsEvaluations using expert-annotated landmarks and augmented test data demonstrate that BigReg approaches the accuracy of landmark-based registration with a landmark distance (LMD) of 8.36±0.12 μm and a landmark fitness (LM fitness) of 85.71%±1.02%. Moreover, BigReg can provide an optimal initialization for mutual information-based methods that otherwise fail independently, further reducing LMD to 7.24±0.11 μm and increasing LM fitness to 93.90%±0.77%.ConclusionsTo the best of our knowledge, BigReg is the first automated method to successfully register XRM and LSFM volumes without requiring manual intervention or prior alignment cues. Its ability to accurately align fine-scale structures, such as lacunae in XRM and osteocytes in LSFM, opens up new avenues for quantitative, multimodal analysis of bone microarchitecture and disease pathology, particularly in studies of osteoporosis.
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (05) , 054004-13
BigReg: an efficient registration pipeline for high-resolution X-ray and light-sheet fluorescence microscopy
PurposeWe aim to propose a reliable registration pipeline tailored for multimodal mouse bone imaging using X-ray microscopy (XRM) and light-sheet fluorescence microscopy (LSFM). These imaging modalities have emerged as pivotal tools in preclinical research, particularly for studying bone remodeling diseases such as osteoporosis. Although multimodal registration enables micrometer-level structural correspondence and facilitates functional analysis, conventional landmark-, feature-, or intensity-based approaches are often infeasible due to inconsistent signal characteristics and significant misalignment resulting from independent scanning, especially in real-world and reference-free scenarios.ApproachTo address these challenges, we introduce BigReg, an automatic, two-stage registration pipeline optimized for high-resolution XRM and LSFM volumes. The first stage involves extracting surface features and applying two successive global-to-local point-cloud-based methods for coarse alignment. The subsequent stage refines this alignment in the 3D Fourier domain using a modified cross-correlation technique, achieving precise volumetric registration.ResultsEvaluations using expert-annotated landmarks and augmented test data demonstrate that BigReg approaches the accuracy of landmark-based registration with a landmark distance (LMD) of 8.36±0.12 μm and a landmark fitness (LM fitness) of 85.71%±1.02%. Moreover, BigReg can provide an optimal initialization for mutual information-based methods that otherwise fail independently, further reducing LMD to 7.24±0.11 μm and increasing LM fitness to 93.90%±0.77%.ConclusionsTo the best of our knowledge, BigReg is the first automated method to successfully register XRM and LSFM volumes without requiring manual intervention or prior alignment cues. Its ability to accurately align fine-scale structures, such as lacunae in XRM and osteocytes in LSFM, opens up new avenues for quantitative, multimodal analysis of bone microarchitecture and disease pathology, particularly in studies of osteoporosis.
- 23 March 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 278
Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection
- 23 March 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 278
Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection
- Open Access
- 20 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7) , 075005
DRACO: differentiable reconstruction for arbitrary CBCT orbits
Objective. This study introduces a novel method for reconstructing cone beam computed tomography (CBCT) images for arbitrary orbits, addressing the computational and memory challenges associated with traditional iterative reconstruction algorithms. Approach. The proposed method employs a differentiable shift-variant filtered backprojection neural network, optimized for arbitrary trajectories. By integrating known operators into the learning model, the approach minimizes the number of trainable parameters while enhancing model interpretability. This framework adapts seamlessly to specific orbit geometries, including non-continuous trajectories such as circular-plus-arc or sinusoidal paths, enabling faster and more accurate CBCT reconstructions. Main results. Experimental validation demonstrates that the method significantly accelerates reconstruction, reducing computation time by over 97% compared to conventional iterative algorithms. It achieves superior or comparable image quality with reduced noise, as evidenced by a 38.6% reduction in mean squared error, a 7.7% increase in peak signal-to-noise ratio, and a 5.0% improvement in the structural similarity index measure. The flexibility and robustness of the approach are confirmed through its ability to handle data from diverse scan geometries. Significance. This method represents a significant advancement in interventional medical imaging, particularly for robotic C-arm CT systems, enabling real-time, high-quality CBCT reconstructions for customized orbits. It offers a transformative solution for clinical applications requiring computational efficiency and precision in imaging.
- 20 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7) , 075005
Open AccessDRACO: differentiable reconstruction for arbitrary CBCT orbits
Objective. This study introduces a novel method for reconstructing cone beam computed tomography (CBCT) images for arbitrary orbits, addressing the computational and memory challenges associated with traditional iterative reconstruction algorithms. Approach. The proposed method employs a differentiable shift-variant filtered backprojection neural network, optimized for arbitrary trajectories. By integrating known operators into the learning model, the approach minimizes the number of trainable parameters while enhancing model interpretability. This framework adapts seamlessly to specific orbit geometries, including non-continuous trajectories such as circular-plus-arc or sinusoidal paths, enabling faster and more accurate CBCT reconstructions. Main results. Experimental validation demonstrates that the method significantly accelerates reconstruction, reducing computation time by over 97% compared to conventional iterative algorithms. It achieves superior or comparable image quality with reduced noise, as evidenced by a 38.6% reduction in mean squared error, a 7.7% increase in peak signal-to-noise ratio, and a 5.0% improvement in the structural similarity index measure. The flexibility and robustness of the approach are confirmed through its ability to handle data from diverse scan geometries. Significance. This method represents a significant advancement in interventional medical imaging, particularly for robotic C-arm CT systems, enabling real-time, high-quality CBCT reconstructions for customized orbits. It offers a transformative solution for clinical applications requiring computational efficiency and precision in imaging.
- Open Access
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (01) , 014001-21
EAGLE: an edge-aware gradient localization enhanced loss for CT image reconstruction
Computed tomography (CT) imaging has become an important tool in modern healthcare, playing a critical role in quantitative diagnosis, evidence-based treatment planning, and patient-centric care across a wide spectrum of disease pathways.1 The quality and speed of CT image reconstruction directly influence the accuracy of diagnosis, and the effectiveness of treatment plans, hence the overall efficiency of clinical workflows.2 Traditional reconstruction methods such as filtered backprojection (FBP) and algebraic reconstruction technique (ART) often face challenges when noise or disturbance is present in the data. These approaches struggle to effectively balance image quality and computational efficiency, particularly in scenarios where such noise, artifacts, or disturbances exist.
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (01) , 014001-21
Open AccessEAGLE: an edge-aware gradient localization enhanced loss for CT image reconstruction
Computed tomography (CT) imaging has become an important tool in modern healthcare, playing a critical role in quantitative diagnosis, evidence-based treatment planning, and patient-centric care across a wide spectrum of disease pathways.1 The quality and speed of CT image reconstruction directly influence the accuracy of diagnosis, and the effectiveness of treatment plans, hence the overall efficiency of clinical workflows.2 Traditional reconstruction methods such as filtered backprojection (FBP) and algebraic reconstruction technique (ART) often face challenges when noise or disturbance is present in the data. These approaches struggle to effectively balance image quality and computational efficiency, particularly in scenarios where such noise, artifacts, or disturbances exist.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 1098-1109
A Gradient-Based Approach to Fast and Accurate Head Motion Compensation in Cone-Beam CT
Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3 mm to 0.61 mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 1098-1109
A Gradient-Based Approach to Fast and Accurate Head Motion Compensation in Cone-Beam CT
Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3 mm to 0.61 mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.
- 3 October 2024
- Published by Springer Nature
- p. 253-263
Differentiable Score-Based Likelihoods: Learning CT Motion Compensation from Clean Images
- 3 October 2024
- Published by Springer Nature
- p. 253-263
Differentiable Score-Based Likelihoods: Learning CT Motion Compensation from Clean Images