A Gradient-Based Approach to Fast and Accurate Head Motion Compensation in Cone-Beam CT
Authors:
- Mareike ThiesMTMareike Thies
- Fabian WagnerFWFabian Wagner
- Noah MaulNMNoah Maul
- Haijun YuHYHaijun Yu
- Manuela GoldmannMGManuela Goldmann
- Linda-Sophie SchneiderLSLinda-Sophie Schneider
- Mingxuan GuMGMingxuan Gu
- Siyuan MeiSMSiyuan Mei
- Lukas FolleLFLukas Folle
- Alexander PreuhsAPAlexander Preuhs
- Michael ManhartMMMichael Manhart
- Andreas MaierAMAndreas Maier
- 4 October 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 1098-1109
Abstract
Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3 mm to 0.61 mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.Keywords
All Related Versions
Funding Information
- European Research Council (ERC) under European Union’s Horizon 2020 Research and Innovation Program (810316)
- German Research Foundation
This publication has 42 references indexed in Scilit:
- Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: A prospective studyEuropean Journal of Radiology, 2021
- Rigid and non-rigid motion artifact reduction in X-ray CT using attention moduleMedical Image Analysis, 2021
- Cone‐beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithmsMedical Physics, 2020
- Technical Note: PYRO‐NN: Python reconstruction operators in neural networksMedical Physics, 2019
- Double Your Views – Exploiting Symmetry in Transmission Imaging2018
- Medical Imaging Systems2018
- The Importance of Skip Connections in Biomedical Image Segmentation2016
- A Novel Approach for Computing Quality Map of Visual Information Fidelity Index2013
- Interventional 4D motion estimation and reconstruction of cardiac vasculature without motion periodicity assumptionMedical Image Analysis, 2010
- The CMA Evolution Strategy: A Comparing Review2007