Wei Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wei Su has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Renhuai Liu
Scienceand Technology on Reliability Physics and Application Technology of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou, China
4 shared publications- Junhua Zhu
Science and Technology on Reliability Physics and Application Technology of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 510610, China
3 shared publications - Ping Lai
Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, No. 5 Electronics Research Institute of the Ministry of Industry and Information Technology, Guangzhou 511370, China
3 shared publications Wenhao Luo
MOE Key Laboratory of Disaster Forecast and Control in Engineering, Guangzhou, China
3 shared publications- Fangfang Song
China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 511370, China
2 shared publications - Hong-Zhong Huang
University of Electronic Science and Technology of China
2 shared publications
Latest Publications
- Open Access
- 11 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1713
Reliability Evaluation Based on Mathematical Degradation Model for Vacuum Packaged MEMS Sensor
Vacuum packaging is used extensively in MEMS sensors for improving performance. However, the vacuum in the MEMS chamber gradually degenerates over time, which adversely affects the long-term performance of the MEMS sensor. A mathematical model for vacuum degradation is presented in this article for evaluating the degradation of vacuum packaged MEMS sensors, and a temperature-accelerated test of MEMS gyroscope with different vacuums is performed. A mathematical degradation model is developed to fit the parameters of the degradation of Q-factor over time at three different temperatures. The results indicate that the outgassing rate at 85 °C is the highest, which is 0.0531 cm2/s; the outgassing rate at 105 °C is the lowest, which is 0.0109 cm2/s; and the outgassing rate at 125 °C is in the middle, which is 0.0373 cm2/s. Due to the different mechanisms by which gas was released, the rate of degradation did not follow this rule. It will also be possible to predict the long-term reliability of vacuum packaged MEMS sensors at room temperature based on this model.
- 11 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1713
Open AccessReliability Evaluation Based on Mathematical Degradation Model for Vacuum Packaged MEMS Sensor
Vacuum packaging is used extensively in MEMS sensors for improving performance. However, the vacuum in the MEMS chamber gradually degenerates over time, which adversely affects the long-term performance of the MEMS sensor. A mathematical model for vacuum degradation is presented in this article for evaluating the degradation of vacuum packaged MEMS sensors, and a temperature-accelerated test of MEMS gyroscope with different vacuums is performed. A mathematical degradation model is developed to fit the parameters of the degradation of Q-factor over time at three different temperatures. The results indicate that the outgassing rate at 85 °C is the highest, which is 0.0531 cm2/s; the outgassing rate at 105 °C is the lowest, which is 0.0109 cm2/s; and the outgassing rate at 125 °C is in the middle, which is 0.0373 cm2/s. Due to the different mechanisms by which gas was released, the rate of degradation did not follow this rule. It will also be possible to predict the long-term reliability of vacuum packaged MEMS sensors at room temperature based on this model.
- 22 February 2022
- Published by Optica Publishing Group in Journal of Optical Communications and Networking
- Vol. 14 (4) , 236-247
Innovation and demonstration of optical service unit-based metro-optimized OTN technologies
To efficiently support the transport of sub-1-Gbps services, an optical service unit (OSU)-based metro-optimized optical transport network (M-OTN) technology framework is proposed and described. The proposed M-OTN/OSU technologies have been implemented by major OTN equipment vendors and verified in a network operator’s lab for the first time to our knowledge. Moreover, a multivendor interoperability test has been conducted in a real-time field trial. The experimental results show that M-OTN/OSU has clear advantages over existing SDH VC/packet-enhanced OTN technologies in several key aspects, e.g., low latency, massive connections, and agile hitless bandwidth adjustment. M-OTN/OSU will be valuable for network operators providing high-quality leased line services and video/VR services in modern OTNs with unprecedented scalability and performance.
- 22 February 2022
- Published by Optica Publishing Group in Journal of Optical Communications and Networking
- Vol. 14 (4) , 236-247
Innovation and demonstration of optical service unit-based metro-optimized OTN technologies
To efficiently support the transport of sub-1-Gbps services, an optical service unit (OSU)-based metro-optimized optical transport network (M-OTN) technology framework is proposed and described. The proposed M-OTN/OSU technologies have been implemented by major OTN equipment vendors and verified in a network operator’s lab for the first time to our knowledge. Moreover, a multivendor interoperability test has been conducted in a real-time field trial. The experimental results show that M-OTN/OSU has clear advantages over existing SDH VC/packet-enhanced OTN technologies in several key aspects, e.g., low latency, massive connections, and agile hitless bandwidth adjustment. M-OTN/OSU will be valuable for network operators providing high-quality leased line services and video/VR services in modern OTNs with unprecedented scalability and performance.
- Open Access
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 129582-129593
Vibration Characteristic Measurement Method of MEMS Gyroscopes in Vacuum, High and Low Temperature Environment and Verification of Excitation Method
A method for measuring vibration characteristics of MEMS (Micro Electro Mechanical System) is presented. This method aims to simulate a real environment where MEMS operates. At first, the method of applying high and low temperature in a vacuum environment is studied. And the excitation method applying to movable microstructures of MEMS in this environment is found. Based on the above environmental conditions, the vibration characteristics of MEMS movable microstructure are measured by micro-laser vibration measurement. The base excitation method is used to measure the vibration characteristics of MEMS movable microstructures outside the plane. ANSYS 14.0 was used for finite element simulation to verify this method. The electrostatic excitation method is used to measure the inside of the plane. The stroboscopic method is used to verify the electrostatic excitation by fitting the displacement signal of the movable microstructure and the excitation output signal. The results show that the out-of-plane first-order frequency is 11.926 kHz, and the error is 0.30% compared with the experimental results. The amplitude is 44.218 nm, and the error is 0.59%. The in-plane first-order frequency is 5715.7Hz, which achieves the requirement of design precision. Both the numerical simulation and the stroboscopic method verify the excitation method well. The effect of temperature on the natural frequency of the structure is negatively correlated. And as the temperature drops, the motion of the structure becomes increasingly violent. The findings of this study provide important guidance for maintenance, reliable operation and optimal design of MEMS.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 129582-129593
Open AccessVibration Characteristic Measurement Method of MEMS Gyroscopes in Vacuum, High and Low Temperature Environment and Verification of Excitation Method
A method for measuring vibration characteristics of MEMS (Micro Electro Mechanical System) is presented. This method aims to simulate a real environment where MEMS operates. At first, the method of applying high and low temperature in a vacuum environment is studied. And the excitation method applying to movable microstructures of MEMS in this environment is found. Based on the above environmental conditions, the vibration characteristics of MEMS movable microstructure are measured by micro-laser vibration measurement. The base excitation method is used to measure the vibration characteristics of MEMS movable microstructures outside the plane. ANSYS 14.0 was used for finite element simulation to verify this method. The electrostatic excitation method is used to measure the inside of the plane. The stroboscopic method is used to verify the electrostatic excitation by fitting the displacement signal of the movable microstructure and the excitation output signal. The results show that the out-of-plane first-order frequency is 11.926 kHz, and the error is 0.30% compared with the experimental results. The amplitude is 44.218 nm, and the error is 0.59%. The in-plane first-order frequency is 5715.7Hz, which achieves the requirement of design precision. Both the numerical simulation and the stroboscopic method verify the excitation method well. The effect of temperature on the natural frequency of the structure is negatively correlated. And as the temperature drops, the motion of the structure becomes increasingly violent. The findings of this study provide important guidance for maintenance, reliable operation and optimal design of MEMS.
- Open Access
- 1 September 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2033 (1) , 012069
Computer Transient Simulation for Dual In-Line Package through Finite Element Analysis and ANASYS Software
The reliability of the DIP package is studied by numerical simulation. Firstly, the DIP package, fixture and metal steel are modeled. Based on this, variable thickness papers are laid on the sample. According to the experiment, corresponding excitation and boundary condition are set. Then, the transient analysis result of DIP package is obtained through numerical simulation. The results show the relation of different thickness papers and acceleration-time curve, which provides a beneficial reference for the optimization of DIP packing.
- 1 September 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2033 (1) , 012069
Open AccessComputer Transient Simulation for Dual In-Line Package through Finite Element Analysis and ANASYS Software
The reliability of the DIP package is studied by numerical simulation. Firstly, the DIP package, fixture and metal steel are modeled. Based on this, variable thickness papers are laid on the sample. According to the experiment, corresponding excitation and boundary condition are set. Then, the transient analysis result of DIP package is obtained through numerical simulation. The results show the relation of different thickness papers and acceleration-time curve, which provides a beneficial reference for the optimization of DIP packing.
- Open Access
- 22 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 1000
Research on Decomposition of Offset in MEMS Capacitive Accelerometer
In a MEMS capacitive accelerometer, there is an offset due to mechanical and electrical factors, and the offset would deteriorate the performance of the accelerometer. Reducing the offset from mechanism would benefit the improvement in performance. Yet, the compositions of the offset are complex and mix together, so it is difficult to decompose the offset to provide guidance for the reduction. In this work, a decomposition method of offset in a MEMS capacitive accelerometer was proposed. The compositions of the offset were first analyzed quantitatively, and methods of measuring key parameters were developed. Based on our proposed decomposition method, the experiment of offset decomposition with a closed-loop MEMS capacitive accelerometer was carried out. The results showed that the offset successfully decomposed, and the major source was from the fabricated gap mismatch in the MEMS sensor. This work provides a new way for analyzing the offset in a MEMS capacitive accelerometer, and it is helpful for purposefully taking steps to reduce the offset and improve accelerometer performance.
- 22 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 1000
Open AccessResearch on Decomposition of Offset in MEMS Capacitive Accelerometer
In a MEMS capacitive accelerometer, there is an offset due to mechanical and electrical factors, and the offset would deteriorate the performance of the accelerometer. Reducing the offset from mechanism would benefit the improvement in performance. Yet, the compositions of the offset are complex and mix together, so it is difficult to decompose the offset to provide guidance for the reduction. In this work, a decomposition method of offset in a MEMS capacitive accelerometer was proposed. The compositions of the offset were first analyzed quantitatively, and methods of measuring key parameters were developed. Based on our proposed decomposition method, the experiment of offset decomposition with a closed-loop MEMS capacitive accelerometer was carried out. The results showed that the offset successfully decomposed, and the major source was from the fabricated gap mismatch in the MEMS sensor. This work provides a new way for analyzing the offset in a MEMS capacitive accelerometer, and it is helpful for purposefully taking steps to reduce the offset and improve accelerometer performance.
- 31 December 2020
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
- Vol. 22 (4) , 705-714
Stress evolution mechanism and thermo-mechanical reliability analysis of copper-filled TSV interposer
Through silicon via (TSV) has become one of the key emerging trends of three-dimensional (3D) packages, as it can realize vertically interconnect between stacked-dies. Due to large mismatch in thermal expansion coefficients (CTE) between the copper via and the silicon, significant mechanical stresses are induced at the interfaces when TSV structure is subjected to thermal stresses, which would greatly affect the reliability and electrical performance of TSV 3D device. In this paper, the relationship between the state of stresses and failure of TSV had been explored by combining finite element model simulation (FEM) and failure physical analysis. The position of the maximum stress of the TSV structure was obtained by FEM analysis. The relationship of stress and displacement change with temperature was also studied. And a thermal cycling experiment was conducted to validate the simulation results. Physical failure analysis after thermal cycling experiment was used to verify the degradation mechanism predicted by thermo-mechanical simulation.
- 31 December 2020
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
- Vol. 22 (4) , 705-714
Stress evolution mechanism and thermo-mechanical reliability analysis of copper-filled TSV interposer
Through silicon via (TSV) has become one of the key emerging trends of three-dimensional (3D) packages, as it can realize vertically interconnect between stacked-dies. Due to large mismatch in thermal expansion coefficients (CTE) between the copper via and the silicon, significant mechanical stresses are induced at the interfaces when TSV structure is subjected to thermal stresses, which would greatly affect the reliability and electrical performance of TSV 3D device. In this paper, the relationship between the state of stresses and failure of TSV had been explored by combining finite element model simulation (FEM) and failure physical analysis. The position of the maximum stress of the TSV structure was obtained by FEM analysis. The relationship of stress and displacement change with temperature was also studied. And a thermal cycling experiment was conducted to validate the simulation results. Physical failure analysis after thermal cycling experiment was used to verify the degradation mechanism predicted by thermo-mechanical simulation.
- 28 October 2020
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 31 (1)
A compact double‐layer wideband circularly polarized microstrip antenna with parasitic elements
In this article, a new broadband circularly polarized (CP) microstrip patch antenna (MPA) with a sequential phase (SP) square‐loop feeding structure is proposed. The presented antenna is composed of a square‐loop feeding structure, four L‐shaped parasitic patches with L‐shaped slots, four parasitic square patches, and a corner‐truncated square patch. At first, a SP square‐loop is designed as a feeding structure. Then, four L‐shaped parasitic patches with L‐shaped slots are utilized to generate one CP mode by a capacitive coupled way. At last, four parasitic square patches and a corner‐truncated square patch are together placed above the SP feeding structure to broaden the circularly polarized bandwidth (CPBW). The presented antenna has a wide 3‐dB axial ratio bandwidth (ARBW) of 16.7% (5.4 GHz, 4.95‐5.85 GHz), and a wide 10‐dB return loss bandwidth of 25.5% (5.5 GHz, 4.8‐6.2 GHz). The proposed antenna features compact structure and broad 3‐AR bandwidth which could completely cover the WLAN (5.725‐5.85GHz) band. Therefore, the proposed antenna is suitable for circular polarization applications in C band.
- 28 October 2020
- Published by Hindawi Limited in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 31 (1)
A compact double‐layer wideband circularly polarized microstrip antenna with parasitic elements
In this article, a new broadband circularly polarized (CP) microstrip patch antenna (MPA) with a sequential phase (SP) square‐loop feeding structure is proposed. The presented antenna is composed of a square‐loop feeding structure, four L‐shaped parasitic patches with L‐shaped slots, four parasitic square patches, and a corner‐truncated square patch. At first, a SP square‐loop is designed as a feeding structure. Then, four L‐shaped parasitic patches with L‐shaped slots are utilized to generate one CP mode by a capacitive coupled way. At last, four parasitic square patches and a corner‐truncated square patch are together placed above the SP feeding structure to broaden the circularly polarized bandwidth (CPBW). The presented antenna has a wide 3‐dB axial ratio bandwidth (ARBW) of 16.7% (5.4 GHz, 4.95‐5.85 GHz), and a wide 10‐dB return loss bandwidth of 25.5% (5.5 GHz, 4.8‐6.2 GHz). The proposed antenna features compact structure and broad 3‐AR bandwidth which could completely cover the WLAN (5.725‐5.85GHz) band. Therefore, the proposed antenna is suitable for circular polarization applications in C band.
- Open Access
- 31 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 158579-158584
A Wideband Folded Reflectarray Antenna Based on Single-Layered Polarization Rotating Metasurface
A wideband folded reflectarray antenna (FRA) based on single-layered polarization rotating metasurface (PRM) is proposed. The FRA is composed of a wideband polarization grid (PG), a wideband PRM and a wideband circular waveguide as the primary source. First, a wideband polarization rotating unit cell consisting of rhombus-shaped metal patch etched on dielectric substrate is designed, which can be used to rotate polarization of the reflective wave 90° relative to that of the incident wave. The element and its mirror image can provide 0°, 90°, 180° and 270° phase shifts with 2-bit phase quantization and relatively higher polarization conversion rates in the Ku band. Due to the introduction of PG and PRM, the distance between the PG surface and the feed phase center can be reduced to about 1/2 of the distance between the imaginary feed and PRM reflectarray. Finally, a wideband FRA consisting of 315 elements with circular aperture is designed, fabricated and measured. The measured results indicate that the proposed antenna achieves 39.5% 3-dB gain bandwidth with 25.5 dBi peak gain at 15 GHz. Its maximum aperture efficiency is about 40%. Low-profile and wideband features of the FRA make it be a candidate in the wireless communication systems.
- 31 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 158579-158584
Open AccessA Wideband Folded Reflectarray Antenna Based on Single-Layered Polarization Rotating Metasurface
A wideband folded reflectarray antenna (FRA) based on single-layered polarization rotating metasurface (PRM) is proposed. The FRA is composed of a wideband polarization grid (PG), a wideband PRM and a wideband circular waveguide as the primary source. First, a wideband polarization rotating unit cell consisting of rhombus-shaped metal patch etched on dielectric substrate is designed, which can be used to rotate polarization of the reflective wave 90° relative to that of the incident wave. The element and its mirror image can provide 0°, 90°, 180° and 270° phase shifts with 2-bit phase quantization and relatively higher polarization conversion rates in the Ku band. Due to the introduction of PG and PRM, the distance between the PG surface and the feed phase center can be reduced to about 1/2 of the distance between the imaginary feed and PRM reflectarray. Finally, a wideband FRA consisting of 315 elements with circular aperture is designed, fabricated and measured. The measured results indicate that the proposed antenna achieves 39.5% 3-dB gain bandwidth with 25.5 dBi peak gain at 15 GHz. Its maximum aperture efficiency is about 40%. Low-profile and wideband features of the FRA make it be a candidate in the wireless communication systems.
- Open Access
- 12 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 452 (2) , 022015
Thermal-Structural Coupling Analysis of PCBA System
In this paper, the thermal and structural analysis of the PCBA system is provided by using the 3-D ANSYS package. The results of thermal and structural analysis for complex and simple model are compared. The paper also describes the deformation analysis of the PCBA system components, and the weak components sensitive to thermal stress are determined though thermal-structual analysis. The results of thermal analysis are helpful to the optimizing overall arrangement design of PCBA system.
- 12 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 452 (2) , 022015
Open AccessThermal-Structural Coupling Analysis of PCBA System
In this paper, the thermal and structural analysis of the PCBA system is provided by using the 3-D ANSYS package. The results of thermal and structural analysis for complex and simple model are compared. The paper also describes the deformation analysis of the PCBA system components, and the weak components sensitive to thermal stress are determined though thermal-structual analysis. The results of thermal analysis are helpful to the optimizing overall arrangement design of PCBA system.