Yuhua Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuhua Yang has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Wendong Zhang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
11 shared publications - Guojun Zhang
North University of China
10 shared publications - Jiangong Cui
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
10 shared publications - Renxin Wang
North University of China
10 shared publications - Changde He
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
9 shared publications - Licheng Jia
North University of China
6 shared publications
Latest Publications
- Open Access
- 24 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 882
A Safe and Portable CMUT Array Ultrasonic System for Bubble Sizing in Industrial Silicone Sealing Rings
To address the need for bubble detection in industrial silicone sealing rings, this paper presents a compact non-invasive ultrasonic monitoring system based on a capacitive micromachined ultrasonic transducer (CMUT) array, aiming to overcome the limitations of conventional X-ray inspection in terms of safety, portability, and real-time in situ monitoring. The system comprises two 8.8 mm × 8.8 mm CMUT arrays with associated transmitting and receiving circuitry. The silicone thickness is determined using the time-of-flight (TOF) method, while bubble size is quantitatively estimated by combining received signal amplitude analysis, which characterizes bubble-induced attenuation, with correlation function evaluation. Experimental measurements on industrial-grade silicone samples and finite element simulations demonstrate that the system achieves a spatial resolution of 0.5 mm and effectively captures attenuation variations caused by bubbles. The integrated strategy of TOF, amplitude analysis, and correlation assessment ensures reliable non-destructive evaluation. Compared with X-ray inspection, the proposed system is safer, more portable, and suitable for real-time on-site monitoring, thereby significantly improving quality control efficiency in silicone manufacturing. This study provides a novel CMUT-array-based solution for quantitative bubble detection in silicone media, offering both high resolution and practical application potential.
- 24 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 882
Open AccessA Safe and Portable CMUT Array Ultrasonic System for Bubble Sizing in Industrial Silicone Sealing Rings
To address the need for bubble detection in industrial silicone sealing rings, this paper presents a compact non-invasive ultrasonic monitoring system based on a capacitive micromachined ultrasonic transducer (CMUT) array, aiming to overcome the limitations of conventional X-ray inspection in terms of safety, portability, and real-time in situ monitoring. The system comprises two 8.8 mm × 8.8 mm CMUT arrays with associated transmitting and receiving circuitry. The silicone thickness is determined using the time-of-flight (TOF) method, while bubble size is quantitatively estimated by combining received signal amplitude analysis, which characterizes bubble-induced attenuation, with correlation function evaluation. Experimental measurements on industrial-grade silicone samples and finite element simulations demonstrate that the system achieves a spatial resolution of 0.5 mm and effectively captures attenuation variations caused by bubbles. The integrated strategy of TOF, amplitude analysis, and correlation assessment ensures reliable non-destructive evaluation. Compared with X-ray inspection, the proposed system is safer, more portable, and suitable for real-time on-site monitoring, thereby significantly improving quality control efficiency in silicone manufacturing. This study provides a novel CMUT-array-based solution for quantitative bubble detection in silicone media, offering both high resolution and practical application potential.
- Open Access
- 30 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (4) , 424
High-Precision Salt Concentration Detection Using a CMUT Array with Temperature Compensation
This paper presents a miniaturized and highly accurate saltwater concentration monitoring system based on Capacitive Micromachined Ultrasonic Transducer (CMUT) array technology. The system incorporates a highly integrated CMUT array with a compact footprint of 5 mm × 5 mm, capable of both transmitting and receiving ultrasonic signals, which significantly contributes to the system’s miniaturization and portability. To ensure accurate compensation for temperature-dependent variations in sound velocity, a TA610A temperature sensor is integrated for continuous real-time monitoring of the salt solution temperature. By acquiring ultrasonic echo signals, the system calculates the time-of-flight (TOF) of the acoustic waves. Based on the TOF and real-time temperature data, the sound velocity is determined, and the salt concentration is subsequently derived with temperature compensation applied to enhance measurement accuracy. Experimental results show a measurement precision of 0.1% and a maximum absolute error of 0.02%, confirming the system’s high accuracy and robustness. Combining stability, reliability, and a compact real-time sensing design, the proposed CMUT-based system holds significant promise for practical deployment in various industrial and environmental monitoring scenarios.
- 30 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (4) , 424
Open AccessHigh-Precision Salt Concentration Detection Using a CMUT Array with Temperature Compensation
This paper presents a miniaturized and highly accurate saltwater concentration monitoring system based on Capacitive Micromachined Ultrasonic Transducer (CMUT) array technology. The system incorporates a highly integrated CMUT array with a compact footprint of 5 mm × 5 mm, capable of both transmitting and receiving ultrasonic signals, which significantly contributes to the system’s miniaturization and portability. To ensure accurate compensation for temperature-dependent variations in sound velocity, a TA610A temperature sensor is integrated for continuous real-time monitoring of the salt solution temperature. By acquiring ultrasonic echo signals, the system calculates the time-of-flight (TOF) of the acoustic waves. Based on the TOF and real-time temperature data, the sound velocity is determined, and the salt concentration is subsequently derived with temperature compensation applied to enhance measurement accuracy. Experimental results show a measurement precision of 0.1% and a maximum absolute error of 0.02%, confirming the system’s high accuracy and robustness. Combining stability, reliability, and a compact real-time sensing design, the proposed CMUT-based system holds significant promise for practical deployment in various industrial and environmental monitoring scenarios.
- Open Access
- 8 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 223
Development of a 1 × 512 Ring Transducer Array-Based 3D Ultrasound Imaging System for Accurate Breast Lesion Detection: Phantom and Preliminary Clinical Feasibility Study
The work presents an algorithm for early detection of breast microlesions using a high resolution three-dimensional ultrasound imaging system. The system employs a 1 × 512 ring transducer array and a triaxial displacement platform with an accuracy of 0.1 mm, achieving high-density acquisition of three-dimensional volumetric data through fixed-step scanning. To improve imaging quality, an adaptive beamforming algorithm incorporating optimal sound speed estimation is proposed, effectively compensating for phase distortion caused by sound speed heterogeneity within tissues and improving spatial coherence and imaging resolution. The three-dimensional volumetric data is visualized using volume rendering to achieve high-fidelity three-dimensional ultrasound image reconstruction. The in vitro experimental results demonstrate that the proposed algorithm improves the system’s spatial resolution to 0.5 mm, with a linear measurement accuracy of 2.1%. A preliminary clinical feasibility case study comparing breast image reconstruction with MRI imaging results shows a Dice similarity coefficient of 0.87 for the lesion region, high anatomical structure reconstruction accuracy, and good spatial consistency. These results demonstrate preliminary clinical feasibility for early detection of breast microlesions.
- 8 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 223
Open AccessDevelopment of a 1 × 512 Ring Transducer Array-Based 3D Ultrasound Imaging System for Accurate Breast Lesion Detection: Phantom and Preliminary Clinical Feasibility Study
The work presents an algorithm for early detection of breast microlesions using a high resolution three-dimensional ultrasound imaging system. The system employs a 1 × 512 ring transducer array and a triaxial displacement platform with an accuracy of 0.1 mm, achieving high-density acquisition of three-dimensional volumetric data through fixed-step scanning. To improve imaging quality, an adaptive beamforming algorithm incorporating optimal sound speed estimation is proposed, effectively compensating for phase distortion caused by sound speed heterogeneity within tissues and improving spatial coherence and imaging resolution. The three-dimensional volumetric data is visualized using volume rendering to achieve high-fidelity three-dimensional ultrasound image reconstruction. The in vitro experimental results demonstrate that the proposed algorithm improves the system’s spatial resolution to 0.5 mm, with a linear measurement accuracy of 2.1%. A preliminary clinical feasibility case study comparing breast image reconstruction with MRI imaging results shows a Dice similarity coefficient of 0.87 for the lesion region, high anatomical structure reconstruction accuracy, and good spatial consistency. These results demonstrate preliminary clinical feasibility for early detection of breast microlesions.
- Open Access
- 1 September 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3108 (1)
Numerical Analysis of a Novel 3D Vector Hydrophone Using COMSOL Multiphysics
Guided by the bionic design concept, this study develops a multiphysics simulation model of a three-dimensional vector hydrophone featuring a “Luban lock” structure to investigate its mechanical behavior and underwater acoustic detection performance. The simulation results show that the natural intrinsic frequency of the design structure reaches 518.15 Hertz under vacuum conditions and decreases to 319.35 Hertz when submerged, which shows good underwater acoustic adaptability. Under X / Y-axis excitation, the maximum stress generated by the device can reach 2 × 105 Pa, while it is 5.7 × 104 Pa under Z-axis excitation, showing significant directional sensitivity. In addition, the sensor exhibits good directivity characteristics on the spatial three-axis. The above simulation analysis provides theoretical support for the parameter optimization and subsequent preparation of Luban lock structure hydrophone, which is helpful to promote its application in the field of ultralow frequency underwater acoustic detection.
- 1 September 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3108 (1)
Open AccessNumerical Analysis of a Novel 3D Vector Hydrophone Using COMSOL Multiphysics
Guided by the bionic design concept, this study develops a multiphysics simulation model of a three-dimensional vector hydrophone featuring a “Luban lock” structure to investigate its mechanical behavior and underwater acoustic detection performance. The simulation results show that the natural intrinsic frequency of the design structure reaches 518.15 Hertz under vacuum conditions and decreases to 319.35 Hertz when submerged, which shows good underwater acoustic adaptability. Under X / Y-axis excitation, the maximum stress generated by the device can reach 2 × 105 Pa, while it is 5.7 × 104 Pa under Z-axis excitation, showing significant directional sensitivity. In addition, the sensor exhibits good directivity characteristics on the spatial three-axis. The above simulation analysis provides theoretical support for the parameter optimization and subsequent preparation of Luban lock structure hydrophone, which is helpful to promote its application in the field of ultralow frequency underwater acoustic detection.
- Open Access
- 31 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (8) , 898
Design and Evaluation of a Capacitive Micromachined Ultrasonic Transducer(CMUT) Linear Array System for Thickness Measurement of Marine Structures Under Varying Environmental Conditions
This paper presents the design, fabrication, and experimental evaluation of a capacitive micromachined ultrasonic transducer (CMUT) linear array for non-contact thickness measurement of marine engineering structures. A 16-element CMUT array was fabricated using a silicon–silicon wafer bonding process, and encapsulated in polyurethane to ensure acoustic impedance matching and environmental protection in underwater conditions. The acoustic performance of the encapsulated CMUT was characterized using standard piezoelectric transducers as reference. The array achieved a transmitting sensitivity of 146.82 dB and a receiving sensitivity of −229.55 dB at 1 MHz. A complete thickness detection system was developed by integrating the CMUT array with a custom transceiver circuit and implementing a time-of-flight (ToF) measurement algorithm. To evaluate environmental robustness, systematic experiments were conducted under varying water temperatures and salinity levels. The results demonstrate that the absolute thickness measurement error remains within ±0.1 mm under all tested conditions, satisfying the accuracy requirements for marine structural health monitoring. The results validate the feasibility of CMUT-based systems for precise and stable thickness measurement in underwater environments, and support their application in non-destructive evaluation of marine infrastructure.
- 31 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (8) , 898
Open AccessDesign and Evaluation of a Capacitive Micromachined Ultrasonic Transducer(CMUT) Linear Array System for Thickness Measurement of Marine Structures Under Varying Environmental Conditions
This paper presents the design, fabrication, and experimental evaluation of a capacitive micromachined ultrasonic transducer (CMUT) linear array for non-contact thickness measurement of marine engineering structures. A 16-element CMUT array was fabricated using a silicon–silicon wafer bonding process, and encapsulated in polyurethane to ensure acoustic impedance matching and environmental protection in underwater conditions. The acoustic performance of the encapsulated CMUT was characterized using standard piezoelectric transducers as reference. The array achieved a transmitting sensitivity of 146.82 dB and a receiving sensitivity of −229.55 dB at 1 MHz. A complete thickness detection system was developed by integrating the CMUT array with a custom transceiver circuit and implementing a time-of-flight (ToF) measurement algorithm. To evaluate environmental robustness, systematic experiments were conducted under varying water temperatures and salinity levels. The results demonstrate that the absolute thickness measurement error remains within ±0.1 mm under all tested conditions, satisfying the accuracy requirements for marine structural health monitoring. The results validate the feasibility of CMUT-based systems for precise and stable thickness measurement in underwater environments, and support their application in non-destructive evaluation of marine infrastructure.
- Open Access
- 11 April 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 454
A Novel AlN/Sc0.2Al0.8N-Based Piezoelectric Composite Thin-Film-Enabled Bioinspired Honeycomb MEMS Hydrophone
An innovative design of a hydrophone based on a piezoelectric composite film of is presented. By designing a non-uniform composite sensitive layer, the dielectric loss and defect density are significantly reduced, while the high-voltage electrical characteristics of scandium-doped aluminum nitride are retained. X-ray diffraction analysis shows that the sensitive films have excellent crystal quality (FWHM is 0.34°). According to the standard underwater acoustic calibration test, the device exhibits full directivity with a minimum deviation of ±0.5 dB at 1 kHz frequency, sound pressure sensitivity of −162.9 dB (re: 1 V/Pa) and equivalent noise density of 46.1 dB (re: 1 Pa/√Hz). The experimental results show that the comprehensive performance of the piezoelectric heterostructure hydrophone meets the standard of commercial high-end hydrophones while maintaining mechanical stability, and provides a new solution for underwater acoustic sensing.- 11 April 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 454
Open AccessA Novel AlN/Sc0.2Al0.8N-Based Piezoelectric Composite Thin-Film-Enabled Bioinspired Honeycomb MEMS Hydrophone
An innovative design of a hydrophone based on a piezoelectric composite film of is presented. By designing a non-uniform composite sensitive layer, the dielectric loss and defect density are significantly reduced, while the high-voltage electrical characteristics of scandium-doped aluminum nitride are retained. X-ray diffraction analysis shows that the sensitive films have excellent crystal quality (FWHM is 0.34°). According to the standard underwater acoustic calibration test, the device exhibits full directivity with a minimum deviation of ±0.5 dB at 1 kHz frequency, sound pressure sensitivity of −162.9 dB (re: 1 V/Pa) and equivalent noise density of 46.1 dB (re: 1 Pa/√Hz). The experimental results show that the comprehensive performance of the piezoelectric heterostructure hydrophone meets the standard of commercial high-end hydrophones while maintaining mechanical stability, and provides a new solution for underwater acoustic sensing. - Open Access
- 28 January 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (3) , 497
Investigation of Submerged MEMS Ultrasonic Sensors for Underwater Obstacle Avoidance Application
Ultrasound is a powerful and versatile technology that has been applied extensively in medicine and scientific research. The development of miniature underwater robots focuses on achieving specific tasks, such as surveys and inspections in confined spaces. However, traditional sonar has limited use in micro underwater robots due to its large size and heavy power demands. Conversely, capacitive micromechanical ultrasonic transducers (CMUTs) offer various advantages, including a wide bandwidth, compact size, and integration feasibility. These attributes make CMUTs a candidate for obstacle avoidance in micro underwater robots. Hence, a novel CMUT structure using Si-Si bonding is proposed. In this design, a membrane isolation layer replaces the cavity bottom isolation layer, simplifying the process and improving bond reliability. A finite element model of the CMUT was constructed in COMSOL and numerically assessed for the CMUT’s operating frequency, collapse voltage, and submerged depth. The CMUT, manufactured using micro-electro-mechanical system (MEMS) technology, undergoes waterproofing with PDMS—A material with similar acoustic impedance to water and corrosion resistance. Underwater tests reveal the CMUT’s resonant frequency in water as approximately 2 MHz, with a −3 dB bandwidth of 108.7%, a transmit/receive beam width of 7.3°, and a standard deviation of measured distance from the true distance of less than 0.05. These outcomes suggest that CMUTs hold promise in obstacle avoidance applications for fish-shaped underwater robots.
- 28 January 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (3) , 497
Open AccessInvestigation of Submerged MEMS Ultrasonic Sensors for Underwater Obstacle Avoidance Application
Ultrasound is a powerful and versatile technology that has been applied extensively in medicine and scientific research. The development of miniature underwater robots focuses on achieving specific tasks, such as surveys and inspections in confined spaces. However, traditional sonar has limited use in micro underwater robots due to its large size and heavy power demands. Conversely, capacitive micromechanical ultrasonic transducers (CMUTs) offer various advantages, including a wide bandwidth, compact size, and integration feasibility. These attributes make CMUTs a candidate for obstacle avoidance in micro underwater robots. Hence, a novel CMUT structure using Si-Si bonding is proposed. In this design, a membrane isolation layer replaces the cavity bottom isolation layer, simplifying the process and improving bond reliability. A finite element model of the CMUT was constructed in COMSOL and numerically assessed for the CMUT’s operating frequency, collapse voltage, and submerged depth. The CMUT, manufactured using micro-electro-mechanical system (MEMS) technology, undergoes waterproofing with PDMS—A material with similar acoustic impedance to water and corrosion resistance. Underwater tests reveal the CMUT’s resonant frequency in water as approximately 2 MHz, with a −3 dB bandwidth of 108.7%, a transmit/receive beam width of 7.3°, and a standard deviation of measured distance from the true distance of less than 0.05. These outcomes suggest that CMUTs hold promise in obstacle avoidance applications for fish-shaped underwater robots.
- Open Access
- 5 June 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (11) , 2949
A Bio-Inspired MEMS Wake Detector for AUV Tracking and Coordinated Formation
AUV (Autonomous Underwater Vehicle) coordinated formation can expand the detection range, improve detection efficiency, and complete complex tasks, which requires each AUV to have the ability to track and locate. A wake detector provides a new technical approach for AUV cooperative formation warfare. Now, most of the existing artificial lateral line detectors are for one-dimensional flow field applications, which are difficult to use for wake detection of AUVs. Therefore, based on the pressure gradient sensing mechanism of the canal neuromasts, we apply Micro-Electro-Mechanical System (MEMS) technology to develop a lateral line-inspired MEMS wake detector. The sensing mechanism, design, and fabrication are demonstrated in detail. Experimental results show the detector’s sensitivity is 147 mV·(m/s)−1, and the detection threshold is 0.3 m/s. In addition, the vector test results verify it has vector-detecting capacity. This wake detector can serve AUVs wake detection and tracking technology, which will be promising in AUV positioning and coordinated formation.
- 5 June 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (11) , 2949
Open AccessA Bio-Inspired MEMS Wake Detector for AUV Tracking and Coordinated Formation
AUV (Autonomous Underwater Vehicle) coordinated formation can expand the detection range, improve detection efficiency, and complete complex tasks, which requires each AUV to have the ability to track and locate. A wake detector provides a new technical approach for AUV cooperative formation warfare. Now, most of the existing artificial lateral line detectors are for one-dimensional flow field applications, which are difficult to use for wake detection of AUVs. Therefore, based on the pressure gradient sensing mechanism of the canal neuromasts, we apply Micro-Electro-Mechanical System (MEMS) technology to develop a lateral line-inspired MEMS wake detector. The sensing mechanism, design, and fabrication are demonstrated in detail. Experimental results show the detector’s sensitivity is 147 mV·(m/s)−1, and the detection threshold is 0.3 m/s. In addition, the vector test results verify it has vector-detecting capacity. This wake detector can serve AUVs wake detection and tracking technology, which will be promising in AUV positioning and coordinated formation.
- Open Access
- 12 January 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (1) , 131
A Flexible Pressure Sensor Based on Silicon Nanomembrane
With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0–200 kPa, and the sensitivity of the sensor reached 0.0185 kPa−1 in the low-pressure range of 0–5 kPa. In the high-pressure range of 5–200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa−1. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.
- 12 January 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (1) , 131
Open AccessA Flexible Pressure Sensor Based on Silicon Nanomembrane
With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0–200 kPa, and the sensitivity of the sensor reached 0.0185 kPa−1 in the low-pressure range of 0–5 kPa. In the high-pressure range of 5–200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa−1. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.
- Open Access
- 7 December 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (24) , 6186
Research on Self-Noise Suppression of Marine Acoustic Sensor Arrays
Marine acoustic sensors can detect underwater acoustic information. The cilium micro-electro-mechanical system (MEMS) vector hydrophone (CVH) is the core component of the ocean noise measurement system. The performance of the CVH, especially its self-noise, has received widespread attention. In this paper, we propose a solution to improve the performance of the CVH using an array to detect environmental noise in a complex deep-water environment. We analyzed the self-noise source of the CVH and the noise suppression principle of the four-unit MEMS vector hydrophone (FUVH). In addition, we designed the pre-circuit of the FUVH, completed the cross-beam structure by the MEMS processing, and packaged a FUVH. Then, we tested the performance of a packaged FUVH. Finally, the experimental results show that the FUVH reduces the self-noise voltage power spectrum by 6 dB compared to the CVH structure. The FUVH achieves better linearity at low frequencies without reducing the bandwidth and sensitivity. In addition, it minimizes the equivalent self-noise levels by 5.18 and 5.14 dB in the X and Y channels, respectively.
- 7 December 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (24) , 6186
Open AccessResearch on Self-Noise Suppression of Marine Acoustic Sensor Arrays
Marine acoustic sensors can detect underwater acoustic information. The cilium micro-electro-mechanical system (MEMS) vector hydrophone (CVH) is the core component of the ocean noise measurement system. The performance of the CVH, especially its self-noise, has received widespread attention. In this paper, we propose a solution to improve the performance of the CVH using an array to detect environmental noise in a complex deep-water environment. We analyzed the self-noise source of the CVH and the noise suppression principle of the four-unit MEMS vector hydrophone (FUVH). In addition, we designed the pre-circuit of the FUVH, completed the cross-beam structure by the MEMS processing, and packaged a FUVH. Then, we tested the performance of a packaged FUVH. Finally, the experimental results show that the FUVH reduces the self-noise voltage power spectrum by 6 dB compared to the CVH structure. The FUVH achieves better linearity at low frequencies without reducing the bandwidth and sensitivity. In addition, it minimizes the equivalent self-noise levels by 5.18 and 5.14 dB in the X and Y channels, respectively.