Wang Xi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wang Xi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Weigang Lu
Yangzhou University
5 shared publications - Jianfeng Liu
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
3 shared publications - Chuan Wang
College of Hydraulic Science and Engineering, Yangzhou University 4 , Yangzhou
2 shared publications - Tao Jiang
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
2 shared publications - Ang Li
Yangzhou Urban Riverway Management Office, Yangzhou 225100, China
1 shared publication - Bin Xi
Yangzhou University, Yangzhou, Jiangsu, China
1 shared publication
Latest Publications
- Open Access
- 9 August 2026
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 14 (16) , 1466
Hydraulic Mechanism and Flow Pattern Optimization of Special Orthogonal Lateral-Intake Pumping Stations in Coastal Hydraulic Hubs
Special orthogonal lateral-intake pumping stations on coastal plains face severe lateral deflection and recirculation in the approach channel and forebay. Their underlying evolutionary mechanisms remain unclear, and conventional rectification methods cause substantial hydraulic losses. Using numerical simulations and hydraulic model experiments, this study investigates these unfavorable flow patterns and proposes an original Combined Arc-Frame Flow Straightening Structure (CAFS). This newly proposed CAFS differs from existing structures, achieving effective flow pattern improvement with reduced hydraulic loss. Results reveal three typical flow regimes—S-shaped mainstream, branching flow, and recirculation—and the flow field is partitioned into four hydrodynamic zones: the Mainstream Incident Zone, Mainstream Impact Zone, Mainstream Reflection Zone, and Low-Velocity Recirculation Zone. Axial velocity uniformity and flow angle are strongly influenced by lateral velocity, while turbulent kinetic energy exhibits intrinsic correlations with vertical vorticity. Lateral velocity, recirculation intensity, and hydraulic losses all increase positively with the Froude number. The CAFS effectively suppresses the low-velocity recirculation zone. Quantitative data show an improvement of 46.40 percentage points in uniformity of axial velocity distribution, a reduction of 0.157 rad (9°) in velocity-weighted average angle, 60.98% less turbulent dissipation, and 38.85% less total hydraulic loss. This study clarifies lateral-intake defect mechanisms and provides a valuable engineering reference.
- 9 August 2026
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 14 (16) , 1466
Open AccessHydraulic Mechanism and Flow Pattern Optimization of Special Orthogonal Lateral-Intake Pumping Stations in Coastal Hydraulic Hubs
Special orthogonal lateral-intake pumping stations on coastal plains face severe lateral deflection and recirculation in the approach channel and forebay. Their underlying evolutionary mechanisms remain unclear, and conventional rectification methods cause substantial hydraulic losses. Using numerical simulations and hydraulic model experiments, this study investigates these unfavorable flow patterns and proposes an original Combined Arc-Frame Flow Straightening Structure (CAFS). This newly proposed CAFS differs from existing structures, achieving effective flow pattern improvement with reduced hydraulic loss. Results reveal three typical flow regimes—S-shaped mainstream, branching flow, and recirculation—and the flow field is partitioned into four hydrodynamic zones: the Mainstream Incident Zone, Mainstream Impact Zone, Mainstream Reflection Zone, and Low-Velocity Recirculation Zone. Axial velocity uniformity and flow angle are strongly influenced by lateral velocity, while turbulent kinetic energy exhibits intrinsic correlations with vertical vorticity. Lateral velocity, recirculation intensity, and hydraulic losses all increase positively with the Froude number. The CAFS effectively suppresses the low-velocity recirculation zone. Quantitative data show an improvement of 46.40 percentage points in uniformity of axial velocity distribution, a reduction of 0.157 rad (9°) in velocity-weighted average angle, 60.98% less turbulent dissipation, and 38.85% less total hydraulic loss. This study clarifies lateral-intake defect mechanisms and provides a valuable engineering reference.
- 1 April 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (4)
Frictional hysteresis effects on the structural optimization of a side pump sump inflow channel
In multi-unit rural irrigation and drainage pump stations, unstable intake flow in side pump sumps often leads to vortex formation, jeopardizing safe operation. Therefore, this study investigates the influence of frictional hysteresis effects on flow patterns in the side pump sump of multi-unit rural irrigation and drainage pump stations through physical model experiments and theoretical analysis. Here, frictional hysteresis refers to the delayed and asymmetric development of wall-induced friction gradients along the sidewall and separating pier, resulting from different boundary-layer growth histories under asymmetric geometric constraints, which leads to persistent lateral momentum imbalance and biased inflow in the sump. The research reveals that due to structural asymmetry (the coexistence of a single-sidewall and a separating pier), frictional gradient deviation in side pump sump exhibits significantly non-uniform distribution along the flow direction. Specifically, the frictional gradient offset near the separating pier is greater than that near the sidewall and decreases along the flow direction while remaining relatively stable. By introducing the concept of the relative offset of inflow frictional gradient, the proportion of gradient offset to pump sump width was quantified. Experimental results show that when the width-to-length ratio is optimized to the range of 0.22–0.28. This significantly promotes a more laterally symmetric velocity distribution and effectively suppresses the formation of wall-attached vortices in side pump sumps. The findings provide a theoretical basis for optimizing rural irrigation and drainage pump station's intake structures, and it is recommended to control width-to-length ratio to reduce frictional hysteresis effects, thereby enhancing operational efficiency and stability.
- 1 April 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (4)
Frictional hysteresis effects on the structural optimization of a side pump sump inflow channel
In multi-unit rural irrigation and drainage pump stations, unstable intake flow in side pump sumps often leads to vortex formation, jeopardizing safe operation. Therefore, this study investigates the influence of frictional hysteresis effects on flow patterns in the side pump sump of multi-unit rural irrigation and drainage pump stations through physical model experiments and theoretical analysis. Here, frictional hysteresis refers to the delayed and asymmetric development of wall-induced friction gradients along the sidewall and separating pier, resulting from different boundary-layer growth histories under asymmetric geometric constraints, which leads to persistent lateral momentum imbalance and biased inflow in the sump. The research reveals that due to structural asymmetry (the coexistence of a single-sidewall and a separating pier), frictional gradient deviation in side pump sump exhibits significantly non-uniform distribution along the flow direction. Specifically, the frictional gradient offset near the separating pier is greater than that near the sidewall and decreases along the flow direction while remaining relatively stable. By introducing the concept of the relative offset of inflow frictional gradient, the proportion of gradient offset to pump sump width was quantified. Experimental results show that when the width-to-length ratio is optimized to the range of 0.22–0.28. This significantly promotes a more laterally symmetric velocity distribution and effectively suppresses the formation of wall-attached vortices in side pump sumps. The findings provide a theoretical basis for optimizing rural irrigation and drainage pump station's intake structures, and it is recommended to control width-to-length ratio to reduce frictional hysteresis effects, thereby enhancing operational efficiency and stability.
- Open Access
Influence Mechanism of Particle Diameter and Volume Fraction on the Solid–Liquid Two-Phase Flow Performance of Semi-Open Impeller Sewage Pumps
Semi-open impeller sewage pumps are widely used in fields such as municipal wastewater treatment. However, they often face performance degradation and operational instability when conveying solid–liquid two-phase flows containing solid particles. This study aims to systematically elucidate the influence mechanisms of particle diameter (0.5–3.0 mm) and volume fraction (1–20%) on the external characteristics and internal flow field of semi-open impeller sewage pumps, providing a theoretical basis for optimizing their design and operational stability. Using an 80WQ4QG-type sewage pump as the research subject, this study employed a combination of numerical simulation and experimental research. The standard k-ε turbulence model coupled with the Discrete Phase (Particle) approach was adopted for multi-condition solid–liquid two-phase flow simulations. Furthermore, two-way analysis of variance (two-way ANOVA) was utilized to quantify the main effects and interaction effects of the parameters. The results indicate that the pump head and efficiency generally exhibit a decreasing trend with increasing particle diameter or volume fraction, with particle diameter exerting a more pronounced effect (p < 0.01). When the particle diameter increased to 3.0 mm, the head decreased by 5.66%; when the volume fraction rose to 20%, the head decreased by 4.17%. It is noteworthy that the combination of a 0.5 mm particle diameter and a 20% volume fraction resulted in an abnormal increase in head, suggesting a possible flow pattern optimization under specific conditions. Analysis of the internal flow field reveals that coarse particles (≥1.5 mm) intensify the pressure gradient disparity between the front and rear shroud cavities of the impeller, thereby increasing the axial thrust. A high volume fraction (≥10%) promotes pronounced flow separation in the volute tongue region and exacerbates the risk of localized erosion at the outlet.
Open AccessInfluence Mechanism of Particle Diameter and Volume Fraction on the Solid–Liquid Two-Phase Flow Performance of Semi-Open Impeller Sewage Pumps
Semi-open impeller sewage pumps are widely used in fields such as municipal wastewater treatment. However, they often face performance degradation and operational instability when conveying solid–liquid two-phase flows containing solid particles. This study aims to systematically elucidate the influence mechanisms of particle diameter (0.5–3.0 mm) and volume fraction (1–20%) on the external characteristics and internal flow field of semi-open impeller sewage pumps, providing a theoretical basis for optimizing their design and operational stability. Using an 80WQ4QG-type sewage pump as the research subject, this study employed a combination of numerical simulation and experimental research. The standard k-ε turbulence model coupled with the Discrete Phase (Particle) approach was adopted for multi-condition solid–liquid two-phase flow simulations. Furthermore, two-way analysis of variance (two-way ANOVA) was utilized to quantify the main effects and interaction effects of the parameters. The results indicate that the pump head and efficiency generally exhibit a decreasing trend with increasing particle diameter or volume fraction, with particle diameter exerting a more pronounced effect (p < 0.01). When the particle diameter increased to 3.0 mm, the head decreased by 5.66%; when the volume fraction rose to 20%, the head decreased by 4.17%. It is noteworthy that the combination of a 0.5 mm particle diameter and a 20% volume fraction resulted in an abnormal increase in head, suggesting a possible flow pattern optimization under specific conditions. Analysis of the internal flow field reveals that coarse particles (≥1.5 mm) intensify the pressure gradient disparity between the front and rear shroud cavities of the impeller, thereby increasing the axial thrust. A high volume fraction (≥10%) promotes pronounced flow separation in the volute tongue region and exacerbates the risk of localized erosion at the outlet.
- Open Access
- 9 December 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (12) , 2345
Optimization of Vortex Well Alga Extractor Based on PSO-GP
As the global environment continues to deteriorate, water blooms and red tides occur more frequently, making it increasingly important to control eutrophication in water bodies. This study focuses on optimizing an adjustable vortex well alga extractor for deep-well alga removal to reduce the risks associated with algal blooms and red tides. Numerical simulation was employed to model the working process of the vortex well alga extractor and to determine its most efficient structural parameters. The optimal dimensions of the adjustable vortex well alga collector optimized by the PSO-GP model are as follows: during the experiment, the water depth at the suction inlet is 200 mm, the diameter of the suction inlet is 480 mm, the distance of the fence is 2000 mm, and the average flow velocity of the water area is 0.12 m/s. Under these conditions, the working flow rate of the pressurizer can reach up to 18,400 cubic meters per hour at a maximum. Under these conditions, the collection efficiency for blue-green algae can reach 92%. The proposed optimization method can assist project managers in improving the design and operation of deep-well alga removal systems, achieving higher accuracy and efficiency, conserving energy, and enhancing overall alga removal performance.
- 9 December 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (12) , 2345
Open AccessOptimization of Vortex Well Alga Extractor Based on PSO-GP
As the global environment continues to deteriorate, water blooms and red tides occur more frequently, making it increasingly important to control eutrophication in water bodies. This study focuses on optimizing an adjustable vortex well alga extractor for deep-well alga removal to reduce the risks associated with algal blooms and red tides. Numerical simulation was employed to model the working process of the vortex well alga extractor and to determine its most efficient structural parameters. The optimal dimensions of the adjustable vortex well alga collector optimized by the PSO-GP model are as follows: during the experiment, the water depth at the suction inlet is 200 mm, the diameter of the suction inlet is 480 mm, the distance of the fence is 2000 mm, and the average flow velocity of the water area is 0.12 m/s. Under these conditions, the working flow rate of the pressurizer can reach up to 18,400 cubic meters per hour at a maximum. Under these conditions, the collection efficiency for blue-green algae can reach 92%. The proposed optimization method can assist project managers in improving the design and operation of deep-well alga removal systems, achieving higher accuracy and efficiency, conserving energy, and enhancing overall alga removal performance.
- Open Access
- 31 January 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (2) , 274
Inlet Passage Hydraulic Performance Optimization of Coastal Drainage Pump System Based on Machine Learning Algorithms
The axial-flow pump system has been widely applied to coastal drainage pump stations, but the hydraulic performance optimization based on the contraction angles of the inlet passage has not been studied. This paper combined the computational fluid dynamics (CFD) method, machine learning (ML) algorithms and genetic algorithm (GA) to find the optimal contraction angles of the inlet passage. The 125 sets of comprehensive objective function were obtained by the CFD method. Three contraction angles and comprehensive objective function values were regressed by three ML algorithms. After hyperparameter optimization, the Gaussian process regression (GPR) model had the highest R2 = 0.958 in the test set and had the strongest generalization ability among the three models. The impact degree of the three contraction angles on the objective function of the GPR model was investigated by the Sobol sensitivity analysis method; the results indicated that the order of impact degree from high to low was . The optimal objective function values of the GPR model and corresponding contraction angles were searched through GA; the maximum objective function value was 0.963 and corresponding contraction angles were , and , respectively. The results of this study can provide reference for the optimization of inlet passages in coastal drainage pump systems.- 31 January 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (2) , 274
Open AccessInlet Passage Hydraulic Performance Optimization of Coastal Drainage Pump System Based on Machine Learning Algorithms
The axial-flow pump system has been widely applied to coastal drainage pump stations, but the hydraulic performance optimization based on the contraction angles of the inlet passage has not been studied. This paper combined the computational fluid dynamics (CFD) method, machine learning (ML) algorithms and genetic algorithm (GA) to find the optimal contraction angles of the inlet passage. The 125 sets of comprehensive objective function were obtained by the CFD method. Three contraction angles and comprehensive objective function values were regressed by three ML algorithms. After hyperparameter optimization, the Gaussian process regression (GPR) model had the highest R2 = 0.958 in the test set and had the strongest generalization ability among the three models. The impact degree of the three contraction angles on the objective function of the GPR model was investigated by the Sobol sensitivity analysis method; the results indicated that the order of impact degree from high to low was . The optimal objective function values of the GPR model and corresponding contraction angles were searched through GA; the maximum objective function value was 0.963 and corresponding contraction angles were , and , respectively. The results of this study can provide reference for the optimization of inlet passages in coastal drainage pump systems. - Open Access
- 4 July 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (7) , 1124
Optimization Design of Radial Clearance between Stator and Rotor of Full Cross-Flow Pump Units
Influenced by the clearance flow between stator and rotor, the operational performance and hydraulic performance of full cross-flow pump units are often worse than that of semi-cross-flow pumps. In order to explore the influence mechanism of clearance structural parameters on clearance flow and provide a reliable scientific support for the improvement of both external and internal characteristics of full cross-flow pump units, firstly, the optimization of the stator–rotor clearance structure was studied as research entry point and the radial inlet and outlet clearance width were taken to set up design variables. Secondly, to establish a comprehensive optimization objective function considering both the operational performance and the hydraulic performance of the pump, the information weight method was adopted by weighting four evaluation indexes, namely, head coefficient, efficiency coefficient, vortex average radial deflection coefficient and axial velocity uniformity coefficient, which were calculated by numerical simulation. Finally, the relevant optimization design analysis was carried out by establishing the response surface model, with the optimal objective value obtained by conducting the steepest-descent method. The results show that the response of the radial inlet and outlet clearance width coefficient between stator and rotor to the comprehensive objective function is not directly coupled and the influence of the radial inlet clearance width coefficient on the objective function is higher than that of the radial outlet clearance width coefficient. The parameter optimization outcomes are as follows: the width coefficient of radial inlet clearance between stator and rotor is 2.2 and that of radial outlet clearance is 3.6, in which case the disturbance effect of clearance flow on the mainstream flow pattern in the pump can be significantly reduced, with the export cyclic quantity of the guide vane obviously decreased and the outlet flow pattern of the pump unit greatly improved. Verified by the model test, the average lift of the pump unit was increased by about 7.6% and the maximum promotion of the unit efficiency reached 5.2%.
- 4 July 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (7) , 1124
Open AccessOptimization Design of Radial Clearance between Stator and Rotor of Full Cross-Flow Pump Units
Influenced by the clearance flow between stator and rotor, the operational performance and hydraulic performance of full cross-flow pump units are often worse than that of semi-cross-flow pumps. In order to explore the influence mechanism of clearance structural parameters on clearance flow and provide a reliable scientific support for the improvement of both external and internal characteristics of full cross-flow pump units, firstly, the optimization of the stator–rotor clearance structure was studied as research entry point and the radial inlet and outlet clearance width were taken to set up design variables. Secondly, to establish a comprehensive optimization objective function considering both the operational performance and the hydraulic performance of the pump, the information weight method was adopted by weighting four evaluation indexes, namely, head coefficient, efficiency coefficient, vortex average radial deflection coefficient and axial velocity uniformity coefficient, which were calculated by numerical simulation. Finally, the relevant optimization design analysis was carried out by establishing the response surface model, with the optimal objective value obtained by conducting the steepest-descent method. The results show that the response of the radial inlet and outlet clearance width coefficient between stator and rotor to the comprehensive objective function is not directly coupled and the influence of the radial inlet clearance width coefficient on the objective function is higher than that of the radial outlet clearance width coefficient. The parameter optimization outcomes are as follows: the width coefficient of radial inlet clearance between stator and rotor is 2.2 and that of radial outlet clearance is 3.6, in which case the disturbance effect of clearance flow on the mainstream flow pattern in the pump can be significantly reduced, with the export cyclic quantity of the guide vane obviously decreased and the outlet flow pattern of the pump unit greatly improved. Verified by the model test, the average lift of the pump unit was increased by about 7.6% and the maximum promotion of the unit efficiency reached 5.2%.
- Open Access
- 1 January 2021
- Published by Wiley in Shock and Vibration
- Vol. 2021 (1)
Optimization of the Hollow Rectification Sill in the Forebay of the Pump Station Based on the PSO‐GP Collaborative Algorithm
The layout of the pump station is easily affected by topography, site, and other factors, resulting in poor inlet flow patterns in the forebay, which seriously affect the normal operation of the pump station. To optimize its inlet flow pattern, the size of the hollow rectification sill has been continuously improved through physical model tests to meet the requirements of the required pump station inlet flow field. In this paper, particle swarm optimization (PSO) was combined with the Gaussian process (GP) to establish a particle swarm‐Gaussian process (PSO‐GP) model to predict the velocity uniformity of the inlet sump of pump stations with different hole‐to‐height ratios, hole‐to‐width ratios, upper‐to‐lower sill length ratios, and sill height‐to‐water table ratios. Finally, the hollow rectification sill with the optimal size was obtained and tested in the physical model to compare the rectification effect with other sizes of hollow sills. The results show that the algorithm model can help the traditional physical experiment quickly predict the velocity uniformity of the inlet sump of the pump station. Through the optimization by the PSO‐GP algorithm, we can get the optimal size of the hollow rectification sill. Its hole‐to‐height ratio is 0.62, its hole‐to‐width ratio is 0.37, upper‐to‐lower sill length ratio is 0.63, and sill height‐to‐water table ratio is 0.23. It shows that this method is practical in the optimization design of the hollow rectification sill and provides a new method for the optimization of the flow field in the forebay of the pump station.
- 1 January 2021
- Published by Wiley in Shock and Vibration
- Vol. 2021 (1)
Open AccessOptimization of the Hollow Rectification Sill in the Forebay of the Pump Station Based on the PSO‐GP Collaborative Algorithm
The layout of the pump station is easily affected by topography, site, and other factors, resulting in poor inlet flow patterns in the forebay, which seriously affect the normal operation of the pump station. To optimize its inlet flow pattern, the size of the hollow rectification sill has been continuously improved through physical model tests to meet the requirements of the required pump station inlet flow field. In this paper, particle swarm optimization (PSO) was combined with the Gaussian process (GP) to establish a particle swarm‐Gaussian process (PSO‐GP) model to predict the velocity uniformity of the inlet sump of pump stations with different hole‐to‐height ratios, hole‐to‐width ratios, upper‐to‐lower sill length ratios, and sill height‐to‐water table ratios. Finally, the hollow rectification sill with the optimal size was obtained and tested in the physical model to compare the rectification effect with other sizes of hollow sills. The results show that the algorithm model can help the traditional physical experiment quickly predict the velocity uniformity of the inlet sump of the pump station. Through the optimization by the PSO‐GP algorithm, we can get the optimal size of the hollow rectification sill. Its hole‐to‐height ratio is 0.62, its hole‐to‐width ratio is 0.37, upper‐to‐lower sill length ratio is 0.63, and sill height‐to‐water table ratio is 0.23. It shows that this method is practical in the optimization design of the hollow rectification sill and provides a new method for the optimization of the flow field in the forebay of the pump station.
- 1 November 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 146 (11) , 04020077
Pipe Burst Detection, Localization, and Quantification Using the Transient Pressure Damping Method
The purpose of this paper is to present a technique for burst detection, localization, and cross-sectional area quantification based on the damping of fluid transients. The Fourier components of the transient signal are damped differently due to the presence of the burst and the unsteady friction it causes. An unsteady friction water hammer (UFWH) model has been developed and validated to determine the unsteady friction damping. The burst damping can then be calculated, and this both indicates the presence of the burst and contains information about the burst location and the associated cross-sectional area. The corresponding numerical studies and experimental results are presented in this paper. By applying the technique outlined in this paper, the errors of the resultant burst location from the numerical and experimental analyses are and , respectively.- 1 November 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 146 (11) , 04020077
Pipe Burst Detection, Localization, and Quantification Using the Transient Pressure Damping Method
The purpose of this paper is to present a technique for burst detection, localization, and cross-sectional area quantification based on the damping of fluid transients. The Fourier components of the transient signal are damped differently due to the presence of the burst and the unsteady friction it causes. An unsteady friction water hammer (UFWH) model has been developed and validated to determine the unsteady friction damping. The burst damping can then be calculated, and this both indicates the presence of the burst and contains information about the burst location and the associated cross-sectional area. The corresponding numerical studies and experimental results are presented in this paper. By applying the technique outlined in this paper, the errors of the resultant burst location from the numerical and experimental analyses are and , respectively.