Ang Li
Research Subjects
Research Interests
Ang Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chuan Wang
College of Hydraulic Science and Engineering, Yangzhou University 4 , Yangzhou
1 shared publication - Hao Yu
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
1 shared publication - Hongliang Wang
School of Mechanical Engineering, Changzhou Institute of Technology, Changzhou 213032, China
1 shared publication - Shi Yansheng
SHIMGE Pump Co., Ltd., Taizhou 317525, China
1 shared publication - Shuai Liu
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
1 shared publication - Wang Xi
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
1 shared publication
Latest Publications
- Open Access
Influence Mechanism of Particle Diameter and Volume Fraction on the Solid–Liquid Two-Phase Flow Performance of Semi-Open Impeller Sewage Pumps
Semi-open impeller sewage pumps are widely used in fields such as municipal wastewater treatment. However, they often face performance degradation and operational instability when conveying solid–liquid two-phase flows containing solid particles. This study aims to systematically elucidate the influence mechanisms of particle diameter (0.5–3.0 mm) and volume fraction (1–20%) on the external characteristics and internal flow field of semi-open impeller sewage pumps, providing a theoretical basis for optimizing their design and operational stability. Using an 80WQ4QG-type sewage pump as the research subject, this study employed a combination of numerical simulation and experimental research. The standard k-ε turbulence model coupled with the Discrete Phase (Particle) approach was adopted for multi-condition solid–liquid two-phase flow simulations. Furthermore, two-way analysis of variance (two-way ANOVA) was utilized to quantify the main effects and interaction effects of the parameters. The results indicate that the pump head and efficiency generally exhibit a decreasing trend with increasing particle diameter or volume fraction, with particle diameter exerting a more pronounced effect (p < 0.01). When the particle diameter increased to 3.0 mm, the head decreased by 5.66%; when the volume fraction rose to 20%, the head decreased by 4.17%. It is noteworthy that the combination of a 0.5 mm particle diameter and a 20% volume fraction resulted in an abnormal increase in head, suggesting a possible flow pattern optimization under specific conditions. Analysis of the internal flow field reveals that coarse particles (≥1.5 mm) intensify the pressure gradient disparity between the front and rear shroud cavities of the impeller, thereby increasing the axial thrust. A high volume fraction (≥10%) promotes pronounced flow separation in the volute tongue region and exacerbates the risk of localized erosion at the outlet.
Open AccessInfluence Mechanism of Particle Diameter and Volume Fraction on the Solid–Liquid Two-Phase Flow Performance of Semi-Open Impeller Sewage Pumps
Semi-open impeller sewage pumps are widely used in fields such as municipal wastewater treatment. However, they often face performance degradation and operational instability when conveying solid–liquid two-phase flows containing solid particles. This study aims to systematically elucidate the influence mechanisms of particle diameter (0.5–3.0 mm) and volume fraction (1–20%) on the external characteristics and internal flow field of semi-open impeller sewage pumps, providing a theoretical basis for optimizing their design and operational stability. Using an 80WQ4QG-type sewage pump as the research subject, this study employed a combination of numerical simulation and experimental research. The standard k-ε turbulence model coupled with the Discrete Phase (Particle) approach was adopted for multi-condition solid–liquid two-phase flow simulations. Furthermore, two-way analysis of variance (two-way ANOVA) was utilized to quantify the main effects and interaction effects of the parameters. The results indicate that the pump head and efficiency generally exhibit a decreasing trend with increasing particle diameter or volume fraction, with particle diameter exerting a more pronounced effect (p < 0.01). When the particle diameter increased to 3.0 mm, the head decreased by 5.66%; when the volume fraction rose to 20%, the head decreased by 4.17%. It is noteworthy that the combination of a 0.5 mm particle diameter and a 20% volume fraction resulted in an abnormal increase in head, suggesting a possible flow pattern optimization under specific conditions. Analysis of the internal flow field reveals that coarse particles (≥1.5 mm) intensify the pressure gradient disparity between the front and rear shroud cavities of the impeller, thereby increasing the axial thrust. A high volume fraction (≥10%) promotes pronounced flow separation in the volute tongue region and exacerbates the risk of localized erosion at the outlet.