GEGeorgios Efstathopoulos

Georgios Efstathopoulos

*This is an algorithmically generated author record based on publicly available information.

Georgios Efstathopoulos has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SDN-Based Resilient Smart Grid: The SDN-microSENSE Architecture

    by Panagiotis Radoglou Grammatikis, Panagiotis Sarigiannidis, Christos Dalamagkas, Yannis Spyridis, Thomas Lagkas, Georgios Efstathopoulos, Achilleas Sesis, Ignacio Labrador Pavon, Ruben Trapero Burgos, Rodrigo Diaz, et al.

    The technological leap of smart technologies and the Internet of Things has advanced the conventional model of the electrical power and energy systems into a new digital era, widely known as the Smart Grid. The advent of Smart Grids provides multiple benefits, such as self-monitoring, self-healing and pervasive control. However, it also raises crucial cybersecurity and privacy concerns that can lead to devastating consequences, including cascading effects with other critical infrastructures or even fatal accidents. This paper introduces a novel architecture, which will increase the Smart Grid resiliency, taking full advantage of the Software-Defined Networking (SDN) technology. The proposed architecture called SDN-microSENSE architecture consists of three main tiers: (a) Risk assessment, (b) intrusion detection and correlation and (c) self-healing. The first tier is responsible for evaluating dynamically the risk level of each Smart Grid asset. The second tier undertakes to detect and correlate security events and, finally, the last tier mitigates the potential threats, ensuring in parallel the normal operation of the Smart Grid. It is noteworthy that all tiers of the SDN-microSENSE architecture interact with the SDN controller either for detecting or mitigating intrusions.


  • Open Access

    End-to-End Deep Graph Convolutional Neural Network Approach for Intentional Islanding in Power Systems Considering Load-Generation Balance

    by Zhonglin Sun, Yannis Spyridis, Thomas Lagkas, Achilleas Sesis, Georgios Efstathopoulos, Panagiotis Sarigiannidis

    Intentional islanding is a corrective procedure that aims to protect the stability of the power system during an emergency, by dividing the grid into several partitions and isolating the elements that would cause cascading failures. This paper proposes a deep learning method to solve the problem of intentional islanding in an end-to-end manner. Two types of loss functions are examined for the graph partitioning task, and a loss function is added on the deep learning model, aiming to minimise the load-generation imbalance in the formed islands. In addition, the proposed solution incorporates a technique for merging the independent buses to their nearest neighbour in case there are isolated buses after the clusterisation, improving the final result in cases of large and complex systems. Several experiments demonstrate that the introduced deep learning method provides effective clustering results for intentional islanding, managing to keep the power imbalance low and creating stable islands. Finally, the proposed method is dynamic, relying on real-time system conditions to calculate the result.


  • Open Access

    ARIES: A Novel Multivariate Intrusion Detection System for Smart Grid

    by Panagiotis Radoglou Grammatikis, Panagiotis Sarigiannidis, Georgios Efstathopoulos, Emmanouil Panaousis

    The advent of the Smart Grid (SG) raises severe cybersecurity risks that can lead to devastating consequences. In this paper, we present a novel anomaly-based Intrusion Detection System (IDS), called ARIES (smArt gRid Intrusion dEtection System), which is capable of protecting efficiently SG communications. ARIES combines three detection layers that are devoted to recognising possible cyberattacks and anomalies against (a) network flows, (b) Modbus/Transmission Control Protocol (TCP) packets and (c) operational data. Each detection layer relies on a Machine Learning (ML) model trained using data originating from a power plant. In particular, the first layer (network flow-based detection) performs a supervised multiclass classification, recognising Denial of Service (DoS), brute force attacks, port scanning attacks and bots. The second layer (packet-based detection) detects possible anomalies related to the Modbus packets, while the third layer (operational data based detection) monitors and identifies anomalies upon operational data (i.e., time series electricity measurements). By emphasising on the third layer, the ARIES Generative Adversarial Network (ARIES GAN) with novel error minimisation functions was developed, considering mainly the reconstruction difference. Moreover, a novel reformed conditional input was suggested, consisting of random noise and the signal features at any given time instance. Based on the evaluation analysis, the proposed GAN network overcomes the efficacy of conventional ML methods in terms of Accuracy and the F1 score.