Achilleas Sesis
Achilleas Sesis has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Georgios Efstathopoulos
Infinity Limited, 2A Heigham Road Imperial Offices, London E6 2JG, UK
2 shared publications - Panagiotis Sarigiannidis
Department of Electrical and Computer Engineering, University of Western Macedonia, 50131 Kozani, Greece
2 shared publications - Thomas Lagkas
Department of Informatics, Democritus University of Thrace, 65404 Kavala, Greece
2 shared publications - Yannis Spyridis
Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield S1 3JD, UK
2 shared publications - Achilleas Pasias
Information Technologies Institute, Centre of Research & Technology Hellas
1 shared publication - Alba Colet-Subirachs
Institute for Energy Research of Catalonia (IREC),Power Systems,Sant Adri del Besos,Spain
1 shared publication
Latest Publications
- Open Access
SDN-Based Resilient Smart Grid: The SDN-microSENSE Architecture
The technological leap of smart technologies and the Internet of Things has advanced the conventional model of the electrical power and energy systems into a new digital era, widely known as the Smart Grid. The advent of Smart Grids provides multiple benefits, such as self-monitoring, self-healing and pervasive control. However, it also raises crucial cybersecurity and privacy concerns that can lead to devastating consequences, including cascading effects with other critical infrastructures or even fatal accidents. This paper introduces a novel architecture, which will increase the Smart Grid resiliency, taking full advantage of the Software-Defined Networking (SDN) technology. The proposed architecture called SDN-microSENSE architecture consists of three main tiers: (a) Risk assessment, (b) intrusion detection and correlation and (c) self-healing. The first tier is responsible for evaluating dynamically the risk level of each Smart Grid asset. The second tier undertakes to detect and correlate security events and, finally, the last tier mitigates the potential threats, ensuring in parallel the normal operation of the Smart Grid. It is noteworthy that all tiers of the SDN-microSENSE architecture interact with the SDN controller either for detecting or mitigating intrusions.
Open AccessSDN-Based Resilient Smart Grid: The SDN-microSENSE Architecture
The technological leap of smart technologies and the Internet of Things has advanced the conventional model of the electrical power and energy systems into a new digital era, widely known as the Smart Grid. The advent of Smart Grids provides multiple benefits, such as self-monitoring, self-healing and pervasive control. However, it also raises crucial cybersecurity and privacy concerns that can lead to devastating consequences, including cascading effects with other critical infrastructures or even fatal accidents. This paper introduces a novel architecture, which will increase the Smart Grid resiliency, taking full advantage of the Software-Defined Networking (SDN) technology. The proposed architecture called SDN-microSENSE architecture consists of three main tiers: (a) Risk assessment, (b) intrusion detection and correlation and (c) self-healing. The first tier is responsible for evaluating dynamically the risk level of each Smart Grid asset. The second tier undertakes to detect and correlate security events and, finally, the last tier mitigates the potential threats, ensuring in parallel the normal operation of the Smart Grid. It is noteworthy that all tiers of the SDN-microSENSE architecture interact with the SDN controller either for detecting or mitigating intrusions.
- Open Access
End-to-End Deep Graph Convolutional Neural Network Approach for Intentional Islanding in Power Systems Considering Load-Generation Balance
Intentional islanding is a corrective procedure that aims to protect the stability of the power system during an emergency, by dividing the grid into several partitions and isolating the elements that would cause cascading failures. This paper proposes a deep learning method to solve the problem of intentional islanding in an end-to-end manner. Two types of loss functions are examined for the graph partitioning task, and a loss function is added on the deep learning model, aiming to minimise the load-generation imbalance in the formed islands. In addition, the proposed solution incorporates a technique for merging the independent buses to their nearest neighbour in case there are isolated buses after the clusterisation, improving the final result in cases of large and complex systems. Several experiments demonstrate that the introduced deep learning method provides effective clustering results for intentional islanding, managing to keep the power imbalance low and creating stable islands. Finally, the proposed method is dynamic, relying on real-time system conditions to calculate the result.
Open AccessEnd-to-End Deep Graph Convolutional Neural Network Approach for Intentional Islanding in Power Systems Considering Load-Generation Balance
Intentional islanding is a corrective procedure that aims to protect the stability of the power system during an emergency, by dividing the grid into several partitions and isolating the elements that would cause cascading failures. This paper proposes a deep learning method to solve the problem of intentional islanding in an end-to-end manner. Two types of loss functions are examined for the graph partitioning task, and a loss function is added on the deep learning model, aiming to minimise the load-generation imbalance in the formed islands. In addition, the proposed solution incorporates a technique for merging the independent buses to their nearest neighbour in case there are isolated buses after the clusterisation, improving the final result in cases of large and complex systems. Several experiments demonstrate that the introduced deep learning method provides effective clustering results for intentional islanding, managing to keep the power imbalance low and creating stable islands. Finally, the proposed method is dynamic, relying on real-time system conditions to calculate the result.