Shuxin Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuxin Tian has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chao SiMa
School of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Jining Liu
School of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Ping Ling
Electric Power Research Institute of STATE GRID Shanghai Municipal Electric Power Company, Shanghai 200437, China
1 shared publication - Shurong Wei
Department of Electrical Power Engineering, Shanghai University of Electric Power, Shanghai, China
1 shared publication - Xiangjing Su
Offshore Wind Power Research Institute, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Yang Fu
Engineering Research Center of Offshore Wind Technology Ministry of Education, Shanghai University of Electric Power, Shanghai, China
1 shared publication
Latest Publications
- Open Access
A Multi-Stage Coordinated Volt-Var Optimization for Integrated and Unbalanced Radial Distribution Networks
The growing penetrations of rooftop photovoltaics (PVs) into low-voltage (LV) distribution networks are challenging voltage regulation. Developing an effective volt-var (VV) control has been the focus of many researchers with various approaches proposed so far. However, assuming a single voltage level and balanced network model, widely adopted in existing literatures, tends to cause inaccurate and even infeasible control solutions. Besides, existing distribution VV control studies are usually based on the day-ahead predictions of PV generations and loads, introducing inevitable and non-negligible errors. To address the challenges above, this paper proposes a VV co-optimization across unbalanced medium-voltage (MV) and LV networks, by traditional and emerging techniques, to ensure the network operation with the required power quality. Specifically, the operation of MV delta-connected switched capacitors and LV distributed PV inverters is coordinated, under a three-stage strategy that suits integrated and unbalanced radial distribution networks. The proposal aims to simultaneously improve voltage magnitude and balance profiles while reducing network power loss, at the least controlling cost. To effectively solve the proposed VV optimization problem, a joint solver of the modified particle swarm optimization and the improved direct load flow is employed. Finally, the proposal is evaluated by simulations on real Australian distribution networks over 24 h.
Open AccessA Multi-Stage Coordinated Volt-Var Optimization for Integrated and Unbalanced Radial Distribution Networks
The growing penetrations of rooftop photovoltaics (PVs) into low-voltage (LV) distribution networks are challenging voltage regulation. Developing an effective volt-var (VV) control has been the focus of many researchers with various approaches proposed so far. However, assuming a single voltage level and balanced network model, widely adopted in existing literatures, tends to cause inaccurate and even infeasible control solutions. Besides, existing distribution VV control studies are usually based on the day-ahead predictions of PV generations and loads, introducing inevitable and non-negligible errors. To address the challenges above, this paper proposes a VV co-optimization across unbalanced medium-voltage (MV) and LV networks, by traditional and emerging techniques, to ensure the network operation with the required power quality. Specifically, the operation of MV delta-connected switched capacitors and LV distributed PV inverters is coordinated, under a three-stage strategy that suits integrated and unbalanced radial distribution networks. The proposal aims to simultaneously improve voltage magnitude and balance profiles while reducing network power loss, at the least controlling cost. To effectively solve the proposed VV optimization problem, a joint solver of the modified particle swarm optimization and the improved direct load flow is employed. Finally, the proposal is evaluated by simulations on real Australian distribution networks over 24 h.