Zhen-Wei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhen-Wei Wu has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
- Ling Zhang
Hefei Institutes of Physical Science, Chinese Academy of Sciences
9 shared publications East Team
Institute of Plasma Physics, Chinese Academy of Science, Hefei, CHINA
5 shared publicationsW. Gao
Institute of Plasma Physics, Chinese Academy of Sciences 1 , Hefei 230031, People's Republic of China
4 shared publicationsZ. Xu
School of Electrical and Photoelectronic Engineering, West Anhui University, Lu’an 237012, China
4 shared publications- Bao-Nian Wan
Chinese Academy of Sciences - Hefei Institutes of Physical Sciences
3 shared publications - C. R. Wu
Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui, China
3 shared publications
Latest Publications
- Open Access
- 2 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (1) , eadz3040
Accessing the density-free regime with ECRH-assisted ohmic start-up on EAST
High plasma density operation is crucial for a tokamak to achieve energy breakeven and burning plasma. However, there is often an empirical upper limit of electron density in tokamak operation, namely, the Greenwald density limit n G , above which tokamaks generally disrupt. Achieving high-density operation above the density limit has been a long-standing challenge in magnetic confinement fusion research. Here, we report experimental results on the Experimental Advanced Superconducting Tokamak (EAST) achieving line-averaged electron density in the range of (1.3 to 1.65) n G , significantly above the typical EAST operational range of (0.8 to 1.0) n G . This is performed with electron cyclotron resonance heating (ECRH)–assisted ohmic start-up and sufficiently high initial neutral density. These experiments are shown to operate in the density-free regime first predicted by a recent plasma-wall self-organization theory. These results suggest a promising scheme for substantially increasing the density limit in tokamaks, a critical advancement toward achieving burning plasma.
- 2 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (1) , eadz3040
Open AccessAccessing the density-free regime with ECRH-assisted ohmic start-up on EAST
High plasma density operation is crucial for a tokamak to achieve energy breakeven and burning plasma. However, there is often an empirical upper limit of electron density in tokamak operation, namely, the Greenwald density limit n G , above which tokamaks generally disrupt. Achieving high-density operation above the density limit has been a long-standing challenge in magnetic confinement fusion research. Here, we report experimental results on the Experimental Advanced Superconducting Tokamak (EAST) achieving line-averaged electron density in the range of (1.3 to 1.65) n G , significantly above the typical EAST operational range of (0.8 to 1.0) n G . This is performed with electron cyclotron resonance heating (ECRH)–assisted ohmic start-up and sufficiently high initial neutral density. These experiments are shown to operate in the density-free regime first predicted by a recent plasma-wall self-organization theory. These results suggest a promising scheme for substantially increasing the density limit in tokamaks, a critical advancement toward achieving burning plasma.
- Open Access
- 22 December 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026007
The impact of impurity peaking factor on ion temperature promotion in EAST argon-seeded plasmas
This study investigates the impact of impurity peaking factor ( PF ) on turbulence and ion temperature ( T i ) in Experimental Advanced Superconducting Tokamak (EAST) argon-seeded plasmas. Through controlled impurity injection and comprehensive diagnostic analyses, the experiments demonstrate that both turbulence stabilization and T i enhancement are influenced not only by impurity concentration but also critically by PF . Specifically, impurity seeding induces a steep core impurity density gradient in the unfavorable toroidal field B t , leading to an 18.8% increase in core T i . In contrast, the core impurity density gradient is weaker in the favorable B t , resulting in ne g ligible changes in core T i . Simulation analyses further confirm that high PF suppresses ion temperature gradient (ITG) turbulence, reducing ion thermal diffusivity ( χ i ) and thereby facilitating T i enhancement. This work presents the first experimental evidence on EAST that PF -driven ITG stabilization leads to T i enhancement, offering valuable insights into impurity control strategies and plasma performance optimization for future fusion device.
- 22 December 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026007
Open AccessThe impact of impurity peaking factor on ion temperature promotion in EAST argon-seeded plasmas
This study investigates the impact of impurity peaking factor ( PF ) on turbulence and ion temperature ( T i ) in Experimental Advanced Superconducting Tokamak (EAST) argon-seeded plasmas. Through controlled impurity injection and comprehensive diagnostic analyses, the experiments demonstrate that both turbulence stabilization and T i enhancement are influenced not only by impurity concentration but also critically by PF . Specifically, impurity seeding induces a steep core impurity density gradient in the unfavorable toroidal field B t , leading to an 18.8% increase in core T i . In contrast, the core impurity density gradient is weaker in the favorable B t , resulting in ne g ligible changes in core T i . Simulation analyses further confirm that high PF suppresses ion temperature gradient (ITG) turbulence, reducing ion thermal diffusivity ( χ i ) and thereby facilitating T i enhancement. This work presents the first experimental evidence on EAST that PF -driven ITG stabilization leads to T i enhancement, offering valuable insights into impurity control strategies and plasma performance optimization for future fusion device.
- Open Access
- 1 April 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (4)
Simulation and comparison between multi-fluid and kinetic models of impurity transport
Impurity transport is a highly significant research topic in international fusion plasma simulations, which are mainly simulated by numerical codes at present. Most of the numerical simulation codes for impurity transport adopt multi-fluid or kinetic model to treat impurity particles. Therefore, it is necessary to select a suitable transport model for the simulation process. For impurity particles, if the mean free path of particles λ is much smaller than the gradient scale length of particles λ g, it is sufficient to treat the particles by the multi-fluid model. However, under some conditions, λ will be much larger than λ g. The applicability of the fluid model is limited when λ is larger than or equal to λ g. A comparison with the simulations on impurity transport treated with multi-fluid and kinetic models is necessary, respectively. In this study, the simulation results of carbon (C) impurity transport in the EAST scrape-off layer with the 2D edge plasma fluid code SOLPS-ITER and the 2D Monte Carlo impurity transport code DIVIMP are compared. The comparison between the distributions of carbon impurities ( C 0 ∼ C + 6) in the different ionization states and the CIII emissivity predicted by SOLPS-ITER and DIVIMP shows that the density distributions of carbon atoms C 0 predicted by the SOLPS-ITER and DIVIMP codes are similar. However, for carbon ions in different ionization states, the variations between the density distributions simulated from the SOLPS-ITER and DIVIMP codes can become larger with the increase in ionization states. DIVIMP performs slightly better than SOLPS-ITER in reproducing the shape of the CIII profile when drifts are switched off in SOLPS-ITER, but the difference is extremely small in terms of the uncertainties involved in these calculations.
- 1 April 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (4)
Open AccessSimulation and comparison between multi-fluid and kinetic models of impurity transport
Impurity transport is a highly significant research topic in international fusion plasma simulations, which are mainly simulated by numerical codes at present. Most of the numerical simulation codes for impurity transport adopt multi-fluid or kinetic model to treat impurity particles. Therefore, it is necessary to select a suitable transport model for the simulation process. For impurity particles, if the mean free path of particles λ is much smaller than the gradient scale length of particles λ g, it is sufficient to treat the particles by the multi-fluid model. However, under some conditions, λ will be much larger than λ g. The applicability of the fluid model is limited when λ is larger than or equal to λ g. A comparison with the simulations on impurity transport treated with multi-fluid and kinetic models is necessary, respectively. In this study, the simulation results of carbon (C) impurity transport in the EAST scrape-off layer with the 2D edge plasma fluid code SOLPS-ITER and the 2D Monte Carlo impurity transport code DIVIMP are compared. The comparison between the distributions of carbon impurities ( C 0 ∼ C + 6) in the different ionization states and the CIII emissivity predicted by SOLPS-ITER and DIVIMP shows that the density distributions of carbon atoms C 0 predicted by the SOLPS-ITER and DIVIMP codes are similar. However, for carbon ions in different ionization states, the variations between the density distributions simulated from the SOLPS-ITER and DIVIMP codes can become larger with the increase in ionization states. DIVIMP performs slightly better than SOLPS-ITER in reproducing the shape of the CIII profile when drifts are switched off in SOLPS-ITER, but the difference is extremely small in terms of the uncertainties involved in these calculations.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 123501
Performance improvement of space-resolved extreme ultraviolet spectrometer by use of complementary metal-oxide semiconductor detectors at the Experimental Advanced Superconducting Tokamak
Two pairs of space-resolved extreme ultraviolet (EUV) spectrometers working at 5–138 Å with different vertical observation ranges of −7 ≤ Z ≤ 19 and −18 ≤ Z ≤ 8 cm have been newly developed to observe the radial profile of impurity line emissions and to study the transport of high-Z impurity ions intrinsically existing in EAST tokamak plasmas. Both spectrometers are equipped with a complementary metal-oxide semiconductor (CMOS) detector (Andor Marana-X 4.2B-6, Oxford Instruments) with sensitive area of 13.3 × 13.3 mm2 and number of pixels equal to 2048 × 2048 (6.5 × 6.5 µm2/pixels). Compared to the currently operating space-resolved EUV spectrometers with a charge-coupled detector (CCD: 1024 × 255 pixels, 26 × 26 µm2) working at 30–520 Å, this spectrometer’s performance was substantially improved by using the CMOS detector. First, the spectral resolution measured at full width at half maximum was improved in the whole wavelength range, e.g., Δλ1/2_CMOS = 0.092 Å and Δλ1/2_CCD = 0.124 Å at C VI 33.73 Å and Δλ1/2_CMOS = 0.104 Å and Δλ1/2_CCD = 0.228 Å at Mo XXXI 115.999 Å, thus enabling a more accurate analysis of spectra with complicated structure such as tungsten unresolved transition array in the range 45–65 Å. Second, the temporal resolution was largely improved due to the high-speed data acquisition system of the CMOS detector, e.g., Δt_CMOS = 15 ms/frame and Δt_CCD = 200 ms/frame at routine operation in the radial profile measurement. Third, signal saturation issues that occurred when using the old CCD sensor during impurity accumulation now disappeared entirely using the CMOS detector due to lower exposure time at high readout rates, which largely improved the observation performance in similar impurity burst events. The above-mentioned performance improvements of the space-resolved EUV spectrometer led to a rapid change in the W XXXIII (52.22 Å) radial profile during a single cycle of low-frequency sawtooth oscillation with fst = 5–6 Hz at a sufficient detector count rate.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 123501
Performance improvement of space-resolved extreme ultraviolet spectrometer by use of complementary metal-oxide semiconductor detectors at the Experimental Advanced Superconducting Tokamak
Two pairs of space-resolved extreme ultraviolet (EUV) spectrometers working at 5–138 Å with different vertical observation ranges of −7 ≤ Z ≤ 19 and −18 ≤ Z ≤ 8 cm have been newly developed to observe the radial profile of impurity line emissions and to study the transport of high-Z impurity ions intrinsically existing in EAST tokamak plasmas. Both spectrometers are equipped with a complementary metal-oxide semiconductor (CMOS) detector (Andor Marana-X 4.2B-6, Oxford Instruments) with sensitive area of 13.3 × 13.3 mm2 and number of pixels equal to 2048 × 2048 (6.5 × 6.5 µm2/pixels). Compared to the currently operating space-resolved EUV spectrometers with a charge-coupled detector (CCD: 1024 × 255 pixels, 26 × 26 µm2) working at 30–520 Å, this spectrometer’s performance was substantially improved by using the CMOS detector. First, the spectral resolution measured at full width at half maximum was improved in the whole wavelength range, e.g., Δλ1/2_CMOS = 0.092 Å and Δλ1/2_CCD = 0.124 Å at C VI 33.73 Å and Δλ1/2_CMOS = 0.104 Å and Δλ1/2_CCD = 0.228 Å at Mo XXXI 115.999 Å, thus enabling a more accurate analysis of spectra with complicated structure such as tungsten unresolved transition array in the range 45–65 Å. Second, the temporal resolution was largely improved due to the high-speed data acquisition system of the CMOS detector, e.g., Δt_CMOS = 15 ms/frame and Δt_CCD = 200 ms/frame at routine operation in the radial profile measurement. Third, signal saturation issues that occurred when using the old CCD sensor during impurity accumulation now disappeared entirely using the CMOS detector due to lower exposure time at high readout rates, which largely improved the observation performance in similar impurity burst events. The above-mentioned performance improvements of the space-resolved EUV spectrometer led to a rapid change in the W XXXIII (52.22 Å) radial profile during a single cycle of low-frequency sawtooth oscillation with fst = 5–6 Hz at a sufficient detector count rate.
- 8 September 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (9) , 1-12
Tungsten control in type-I ELMy H-mode plasmas on EAST
- 8 September 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (9) , 1-12
Tungsten control in type-I ELMy H-mode plasmas on EAST
- 1 July 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (7) , 075205
Reduction of impurity confinement time by combined heating of LHW and ECRH in EAST*
The core impurity confinement properties are experimentally investigated in the Experimental Advanced Superconducting Tokamak (EAST) plasma heated by lower hybrid wave (LHW) and electron cyclotron resonance heating (ECRH) (LHW+ECRH). It is shown that the impurity confinement time (τ imp) in the L-mode plasma jointly heated by LHW and ECRH is weakly dependent on electron density but strongly dependent on the heating power, thus it is shorter than that in LHW-only heated L-mode plasma with the similar plasma parameters. The combined heating of LHW and ECRH can reduce the collisionality and indicates a more effective heating method for core τ imp reduction and normalized poloidal beta (β P) improvement. It should be emphasized that in this high β P operation window the small ELM regime can be accessed, and an L-mode level τ imp (40 ms–80 ms) and high β N (∼ 1.7) can be obtained simultaneously. It means that this typical small ELMy H-mode regime has an advantage in avoiding the serious tungsten accumulation, and will be competitive in future long-pulse steady-state and high-performance operation with high-Z material plasma-facing components.
- 1 July 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (7) , 075205
Reduction of impurity confinement time by combined heating of LHW and ECRH in EAST*
The core impurity confinement properties are experimentally investigated in the Experimental Advanced Superconducting Tokamak (EAST) plasma heated by lower hybrid wave (LHW) and electron cyclotron resonance heating (ECRH) (LHW+ECRH). It is shown that the impurity confinement time (τ imp) in the L-mode plasma jointly heated by LHW and ECRH is weakly dependent on electron density but strongly dependent on the heating power, thus it is shorter than that in LHW-only heated L-mode plasma with the similar plasma parameters. The combined heating of LHW and ECRH can reduce the collisionality and indicates a more effective heating method for core τ imp reduction and normalized poloidal beta (β P) improvement. It should be emphasized that in this high β P operation window the small ELM regime can be accessed, and an L-mode level τ imp (40 ms–80 ms) and high β N (∼ 1.7) can be obtained simultaneously. It means that this typical small ELMy H-mode regime has an advantage in avoiding the serious tungsten accumulation, and will be competitive in future long-pulse steady-state and high-performance operation with high-Z material plasma-facing components.
- 14 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10B108
Four-dimensional calibration turntable of the motional Stark effect diagnostic on EAST
The motional Stark effect (MSE) diagnostic is applied to measure the safety factor q and current density profile of a tokamak device, which are important parameters in realizing the high-performance and long-pulse steady state of a tokamak. A single-channel MSE diagnostic based on dual photoelastic modulators, whose sightline meets with the neutral beam injection at a major radius of R = 2.12 m, has been built for the D window of the Experimental Advanced Superconducting Tokamak (EAST). According to the requirements of MSE diagnostic polarimetric calibration, a high-precision four-dimensional calibration turntable, driven by four stepping motors and controlled by software running on the computer, was designed for EAST. The turntable allows us to rapidly calibrate the MSE diagnostic in a series of positions and angles during EAST maintenance. The turntable can move in four dimensions of translation, yaw, pitch, and roll of the polarizer and can create linearly polarized light at any given angle with accuracy of ∼0.05° for the MSE system offline calibration. The experimental results of the MSE diagnostic calibration in the laboratory show that the turntable has the advantages of high positioning accuracy, flexible spatial movement, and convenient control and fully meets the calibration requirements of an MSE diagnosis system.
- 14 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10B108
Four-dimensional calibration turntable of the motional Stark effect diagnostic on EAST
The motional Stark effect (MSE) diagnostic is applied to measure the safety factor q and current density profile of a tokamak device, which are important parameters in realizing the high-performance and long-pulse steady state of a tokamak. A single-channel MSE diagnostic based on dual photoelastic modulators, whose sightline meets with the neutral beam injection at a major radius of R = 2.12 m, has been built for the D window of the Experimental Advanced Superconducting Tokamak (EAST). According to the requirements of MSE diagnostic polarimetric calibration, a high-precision four-dimensional calibration turntable, driven by four stepping motors and controlled by software running on the computer, was designed for EAST. The turntable allows us to rapidly calibrate the MSE diagnostic in a series of positions and angles during EAST maintenance. The turntable can move in four dimensions of translation, yaw, pitch, and roll of the polarizer and can create linearly polarized light at any given angle with accuracy of ∼0.05° for the MSE system offline calibration. The experimental results of the MSE diagnostic calibration in the laboratory show that the turntable has the advantages of high positioning accuracy, flexible spatial movement, and convenient control and fully meets the calibration requirements of an MSE diagnosis system.
- 1 August 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (8) , 082503
Hot spots induced by LHCD in the shadow of antenna limiters in the EAST tokamak
Hot spots induced by lower hybrid wave in experimental advanced superconducting tokamak tokamak have caused high performance experiment disruption and serious damages to the guard limiters. Experimental and theoretical analyses have been carried out to study its physical mechanism. Plasma density scan experiments indicate that the wall temperature within the hot spots enhanced by a factor of 5 and increases with the plasma density near the antenna. A lower hybrid current drive (LHCD)-only density climb experiment shows that the carbon impurity decreases to a minimum value at certain plasma density and then increases with the line averaged plasma density. A model has been developed to explain the mechanism of sputtering of graphite tiles due to hot spots as the plasma density near the LHCD antenna and the time increases. A theoretical scaling of the heat flux driven by LHCD is also presented and is consistent with the experimental scaling in the Tore Supra tokamak. The simulation results show that the total sputtering flux density has a minimum at a certain plasma density and gradually increases as the plasma density increases or decreases away from the minimum value, and the increase in parallel heat flux near the antenna would enhance the sputtering flux density. The sputtering flux density trend is qualitatively consistent with the density scan experiments. The simulated temporal evolution of sputtered flux implies that the chemical sputtering could be a candidate for the carbon impurity explosion.
- 1 August 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (8) , 082503
Hot spots induced by LHCD in the shadow of antenna limiters in the EAST tokamak
Hot spots induced by lower hybrid wave in experimental advanced superconducting tokamak tokamak have caused high performance experiment disruption and serious damages to the guard limiters. Experimental and theoretical analyses have been carried out to study its physical mechanism. Plasma density scan experiments indicate that the wall temperature within the hot spots enhanced by a factor of 5 and increases with the plasma density near the antenna. A lower hybrid current drive (LHCD)-only density climb experiment shows that the carbon impurity decreases to a minimum value at certain plasma density and then increases with the line averaged plasma density. A model has been developed to explain the mechanism of sputtering of graphite tiles due to hot spots as the plasma density near the LHCD antenna and the time increases. A theoretical scaling of the heat flux driven by LHCD is also presented and is consistent with the experimental scaling in the Tore Supra tokamak. The simulation results show that the total sputtering flux density has a minimum at a certain plasma density and gradually increases as the plasma density increases or decreases away from the minimum value, and the increase in parallel heat flux near the antenna would enhance the sputtering flux density. The sputtering flux density trend is qualitatively consistent with the density scan experiments. The simulated temporal evolution of sputtered flux implies that the chemical sputtering could be a candidate for the carbon impurity explosion.
- 1 September 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (9) , 092514
Investigation of the effects of impurity seeding under different magnetic configurations in L-mode plasma in EAST tokamak
Experiments with a small amount of Ar puffed from the lower outer target into L-mode plasma in double null (DN), lower single null (LSN), and upper single null (USN) configurations studied the effects of magnetic configurations and the seeded location relative to the X-point on the performance of Ar seeding. With Ar seeded, the peak heat flux and the integrated power load onto the target decreased most significantly in the LSN configuration, although the increase of the line integrated radiation in the main plasma was the lowest in this case and the highest in the USN configuration. The radiation fraction in the divertor rose from about 10% to 23% of the heating power in LSN, and from around 15% to 22% in DN, while it almost did not change in the USN configuration with Ar seeding. The line emission of Ar XVI increased following the puff and then started to degrade near the end of LSN and USN phases. No such degradation was seen in the DN phase, meaning that some Ar dwelt in the core till the LSN phase began, which explained the peaking of radiation in the core prior to the seeding in the LSN phase. Dedicate Modeling indicates that the LSN configuration has the highest divertor radiation fraction. The highest radiation from outside the divertor is in the USN configuration. With increasing Ar seeding, the LSN configuration sees an increase of the radiation inside the divertor while in the USN configuration, it is the radiation from outside the divertor that increases most strongly. In the DN configuration, the radiation from both inside and outside the divertor increases with seeding, with the former more strongly.
- 1 September 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (9) , 092514
Investigation of the effects of impurity seeding under different magnetic configurations in L-mode plasma in EAST tokamak
Experiments with a small amount of Ar puffed from the lower outer target into L-mode plasma in double null (DN), lower single null (LSN), and upper single null (USN) configurations studied the effects of magnetic configurations and the seeded location relative to the X-point on the performance of Ar seeding. With Ar seeded, the peak heat flux and the integrated power load onto the target decreased most significantly in the LSN configuration, although the increase of the line integrated radiation in the main plasma was the lowest in this case and the highest in the USN configuration. The radiation fraction in the divertor rose from about 10% to 23% of the heating power in LSN, and from around 15% to 22% in DN, while it almost did not change in the USN configuration with Ar seeding. The line emission of Ar XVI increased following the puff and then started to degrade near the end of LSN and USN phases. No such degradation was seen in the DN phase, meaning that some Ar dwelt in the core till the LSN phase began, which explained the peaking of radiation in the core prior to the seeding in the LSN phase. Dedicate Modeling indicates that the LSN configuration has the highest divertor radiation fraction. The highest radiation from outside the divertor is in the USN configuration. With increasing Ar seeding, the LSN configuration sees an increase of the radiation inside the divertor while in the USN configuration, it is the radiation from outside the divertor that increases most strongly. In the DN configuration, the radiation from both inside and outside the divertor increases with seeding, with the former more strongly.
- Open Access
- 26 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E552
Fast-ion Dα spectrum diagnostic in the EAST
In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.
- 26 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E552
Open AccessFast-ion Dα spectrum diagnostic in the EAST
In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.