- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 68 (4) , 1409-1420
A 1.25 μJ per Measurement Ultrasound Rangefinder System in 65 nm CMOS for Explorations With a Swarm of Sensor Nodes
This paper presents an ultrasound rangefinder system able to find relative distances among energy-constrained sensor nodes. The nodes build a swarm that is operated in collision and multipath rich environments. A new distance measurement technique combining Wake-up and Frequency Modulated Continuous Wave (FMCW) is proposed to enable the ranging while neglecting the echoes from passive reflectors in the environment. The building blocks of the sensor nodes comprise a transmitter, a wake-up receiver, and a ranging receiver, all implemented in a 65 nm CMOS technology. The transmitter includes two switched-capacitor converters and an output multiplexer to generate a four-level driving signal and broadcast either a wake-up sequence or a digitally synthesized ultrasound Chirp. The transmitter dissipates 0.43 μJ and 0.82 μJ to broadcast the wake-up signal and the Chirp, respectively. A mixer first architecture is exploited in the wake-up receiver to reduce the always-on power consumption of the nodes. The ranging receiver uses a heterodyne architecture suited for the FMCW. The power consumption of the wake-up receiver and ranging receiver is 23.6 nW and 0.56 μW, respectively. The proposed rangefinder is experimentally characterized up to a 1 m distance in air and dissipates 1.25 μJ per measurement, achieving a resolution of 18.7 mm at 0.55 m.
- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 68 (4) , 1409-1420
A 1.25 μJ per Measurement Ultrasound Rangefinder System in 65 nm CMOS for Explorations With a Swarm of Sensor Nodes
This paper presents an ultrasound rangefinder system able to find relative distances among energy-constrained sensor nodes. The nodes build a swarm that is operated in collision and multipath rich environments. A new distance measurement technique combining Wake-up and Frequency Modulated Continuous Wave (FMCW) is proposed to enable the ranging while neglecting the echoes from passive reflectors in the environment. The building blocks of the sensor nodes comprise a transmitter, a wake-up receiver, and a ranging receiver, all implemented in a 65 nm CMOS technology. The transmitter includes two switched-capacitor converters and an output multiplexer to generate a four-level driving signal and broadcast either a wake-up sequence or a digitally synthesized ultrasound Chirp. The transmitter dissipates 0.43 μJ and 0.82 μJ to broadcast the wake-up signal and the Chirp, respectively. A mixer first architecture is exploited in the wake-up receiver to reduce the always-on power consumption of the nodes. The ranging receiver uses a heterodyne architecture suited for the FMCW. The power consumption of the wake-up receiver and ranging receiver is 23.6 nW and 0.56 μW, respectively. The proposed rangefinder is experimentally characterized up to a 1 m distance in air and dissipates 1.25 μJ per measurement, achieving a resolution of 18.7 mm at 0.55 m.
- 24 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 3, 326-329
A 2.67 μJ per Measurement FMCW Ultrasound Rangefinder System for the Exploration of Enclosed Environments
This paper presents the design and experimental characterization of an ultrasound rangefinder system. A new distance measurement method is proposed for determining the relative position among sensor nodes that are operated in a collision and multipath rich environment, while needing no common time reference between them. A 65nm CMOS technology has been used to build the sensor nodes, which comprise an on-chip receiver and transmitter. The proposed rangefinder system is characterized up to 1m in air and has a range resolution of 6.5mm, while dissipating 2.67μJ per measurement.
- 24 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 3, 326-329
A 2.67 μJ per Measurement FMCW Ultrasound Rangefinder System for the Exploration of Enclosed Environments
This paper presents the design and experimental characterization of an ultrasound rangefinder system. A new distance measurement method is proposed for determining the relative position among sensor nodes that are operated in a collision and multipath rich environment, while needing no common time reference between them. A 65nm CMOS technology has been used to build the sensor nodes, which comprise an on-chip receiver and transmitter. The proposed rangefinder system is characterized up to 1m in air and has a range resolution of 6.5mm, while dissipating 2.67μJ per measurement.