Hohyung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hohyung Lee has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Yuling Niu
Department of Mechanical Engineering, State University of New York at Binghamton, P.O. Box 6000, Binghamton, NY 13902, USA
2 shared publications Huayan Wang
1 shared publicationJing Wang
1 shared publicationS.B. Park
1 shared publication- Seungbae Park
Binghamton University, Binghamton, USA
1 shared publication - Shuai Shao
Department of Mechanical Engineering, State University of New York at Binghamton, P.O. Box 6000, Binghamton, NY 13902, USA
1 shared publication
Latest Publications
- 1 August 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 87, 81-88
A comprehensive solution for electronic packages' reliability assessment with digital image correlation (DIC) method
- 1 August 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 87, 81-88
A comprehensive solution for electronic packages' reliability assessment with digital image correlation (DIC) method
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05695503,p. 425-431
A new in-situ warpage measurement of a wafer with speckle -free digital image correlation (DIC) method
During microelectronic manufacturing, a wafer undergoes many fabrication processes. Such processes include exposing a wafer to high temperature. Significant residual stresses are built up in a wafer and they are manifested as warpage of a wafer. Understanding the wafer behavior, especially warpage, during reflow process becomes one of the most important things in developing assembly process. Three Dimensional (3-D) digital image correlation (DIC), as a non-contact optical deformation measurement method, documents both in-plane and out-of plane deformation. The in-situ measurement capability allows to understand a wafer (or a wafer with multiple chips) behavior during reflow (or assembly) process. However, an object such as a monotonic surface or a mirror like wafer needs artificial speckles on the sample surface to be discernable and measured by DIC technique. To avoid contamination on wafer for surface treatment, a speckle-free 3D DIC method is proposed and its effectiveness is investigated. This method introduces an optical pattern projection method and subsequent processes in documenting topography of a wafer placed in an environmental chamber to mimic a reflow process. To validate the new method, warpage measurement result is compared with the measurement from optical profiler, a white light interferometer, and its accuracy and sensitivity are assessed quantitatively.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05695503,p. 425-431
A new in-situ warpage measurement of a wafer with speckle -free digital image correlation (DIC) method
During microelectronic manufacturing, a wafer undergoes many fabrication processes. Such processes include exposing a wafer to high temperature. Significant residual stresses are built up in a wafer and they are manifested as warpage of a wafer. Understanding the wafer behavior, especially warpage, during reflow process becomes one of the most important things in developing assembly process. Three Dimensional (3-D) digital image correlation (DIC), as a non-contact optical deformation measurement method, documents both in-plane and out-of plane deformation. The in-situ measurement capability allows to understand a wafer (or a wafer with multiple chips) behavior during reflow (or assembly) process. However, an object such as a monotonic surface or a mirror like wafer needs artificial speckles on the sample surface to be discernable and measured by DIC technique. To avoid contamination on wafer for surface treatment, a speckle-free 3D DIC method is proposed and its effectiveness is investigated. This method introduces an optical pattern projection method and subsequent processes in documenting topography of a wafer placed in an environmental chamber to mimic a reflow process. To validate the new method, warpage measurement result is compared with the measurement from optical profiler, a white light interferometer, and its accuracy and sensitivity are assessed quantitatively.