Diyang Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diyang Zou has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Tsung-Yuan Tsai
School of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Nan Zheng
School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Andreas Foesel
<!--1--> Department of Orthopaedics Bürgerspital Solothurn Schöngrünstrasse 38 4500 Solothurn Switzerland
1 shared publication - Bodo Baumgaertner
<!--1--> Department of Orthopaedics Bürgerspital Solothurn Schöngrünstrasse 38 4500 Solothurn Switzerland
1 shared publication - Dimitris Dimitriou
Department of Orthopedics, University Hospital Balgrist, University of Zurich, Zurich, Switzerland
1 shared publication - Jiaqi Tan
Department of Orthopedics, Shanghai Sixth People’s Hospital, Shanghai Jiao Tong University, Shanghai 200233, China
1 shared publication
Latest Publications
- Open Access
- 25 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1006
Development and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force
In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from −6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.
- 25 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1006
Open AccessDevelopment and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force
In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from −6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.
- Open Access
- 23 February 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (3) , 290
Larger Medial Contact Area and More Anterior Contact Position in Medial-Pivot than Posterior-Stabilized Total Knee Arthroplasty during In-Vivo Lunge Activity
This study aimed to compare the in-vivo kinematics and articular contact status between medial-pivot total knee arthroplasty (MP-TKA) and posterior stabilized (PS) TKA during weight-bearing single-leg lunge. 16 MP-TKA and 12 PS-TKA patients performed bilateral single-leg lunges under dual fluoroscopy surveillance to determine the in-vivo six degrees-of-freedom knee kinematics. The closest point between the surface models of the femoral condyle and the polyethylene insert was used to determine the contact position and area. The nonparametric statistics analysis was performed to test the symmetry of the kinematics between MP-TKA and PS-TKA. PS-TKA demonstrated a significantly greater range of AP translation than MP-TKA during high flexion (p = 0.0002). Both groups showed a significantly greater range of lateral compartment posterior translation with medial pivot rotation. The contact points of PS-TKA were located significantly more posterior than MP-TKA in both medial (10°–100°) and lateral (5°–40°, 55°–100°) compartments (p < 0.0500). MP-TKA had a significantly larger contact area in the medial compartment than in the lateral compartment. In contrast, no significant differences were observed in PS-TKA. The present study revealed no significant differences in clinical outcomes between the MP and PS groups. The PS-TKA demonstrated significantly more posterior translations than MP-TKA at high flexion. The contact points are located more posteriorly in PS-TKA compared with MP-TKA. A larger contact area and medial pivot pattern during high flexion in MP-TKA indicated that MP-TKA provides enhanced medial pivot rotation.
- 23 February 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (3) , 290
Open AccessLarger Medial Contact Area and More Anterior Contact Position in Medial-Pivot than Posterior-Stabilized Total Knee Arthroplasty during In-Vivo Lunge Activity
This study aimed to compare the in-vivo kinematics and articular contact status between medial-pivot total knee arthroplasty (MP-TKA) and posterior stabilized (PS) TKA during weight-bearing single-leg lunge. 16 MP-TKA and 12 PS-TKA patients performed bilateral single-leg lunges under dual fluoroscopy surveillance to determine the in-vivo six degrees-of-freedom knee kinematics. The closest point between the surface models of the femoral condyle and the polyethylene insert was used to determine the contact position and area. The nonparametric statistics analysis was performed to test the symmetry of the kinematics between MP-TKA and PS-TKA. PS-TKA demonstrated a significantly greater range of AP translation than MP-TKA during high flexion (p = 0.0002). Both groups showed a significantly greater range of lateral compartment posterior translation with medial pivot rotation. The contact points of PS-TKA were located significantly more posterior than MP-TKA in both medial (10°–100°) and lateral (5°–40°, 55°–100°) compartments (p < 0.0500). MP-TKA had a significantly larger contact area in the medial compartment than in the lateral compartment. In contrast, no significant differences were observed in PS-TKA. The present study revealed no significant differences in clinical outcomes between the MP and PS groups. The PS-TKA demonstrated significantly more posterior translations than MP-TKA at high flexion. The contact points are located more posteriorly in PS-TKA compared with MP-TKA. A larger contact area and medial pivot pattern during high flexion in MP-TKA indicated that MP-TKA provides enhanced medial pivot rotation.
- 24 September 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (6) , 1968-1976
The deep lateral femoral notch sign: a reliable diagnostic tool in identifying a concomitant anterior cruciate and anterolateral ligament injury
Purpose: The aim of the present study was to investigate the validity and reliability of the deep lateral femoral notch sign (DLFNS) in identifying a concomitant anterior cruciate ligament (ACL)/anterolateral ligament (ALL) rupture and predicting the clinical outcomes following an anatomical single‐bundle ACL reconstruction. It was hypothesized that patients with a concomitant ACL/ALL rupture would have an increased DLFNS compared to patients without a concomitant ACL/ALL rupture.Methods: The lateral preoperative radiographs and MRI images of 100 patients with an ACL rupture and 100 control subjects were evaluated for the presence of a DLFNS and ACL/ALL rupture, respectively. The patients were evaluated clinically preoperatively and at a minimum 1 year following the ACL reconstruction. A receiver operator curve (ROC) analysis was performed to define the optimal cut‐off value of the DLFNS for identifying a concomitant ACL/ALL injury. The relative risk (RR) was also calculated to determine whether the presence of the DLFNS was a risk factor for residual instability or ACL graft rupture following an ACL reconstruction.Results: The prevalence of DLFNS was 52% in the ACL‐ruptured patients and 15% in the control group. At a minimum 1‐year follow‐up, 35% (6/17) of the patients with DLFNS > 1.8 mm complained of persistent instability, and an MRI evaluation demonstrated a graft re‐rupture rate of 12% (2/17). In patients with a DLFNS < 1.8 mm, 8% (7/83) reported a residual instability, and the graft rupture rate was 2.4% (2/83). A DLFNS > 1.8 mm demonstrated a sensitivity of 89%, a specificity of 95%, a negative predictive value of 98%, and a positive predictive value of 89% in identifying a concomitant ACL/ALL rupture. Patients with a DLFNS > 1.8 mm had 4.2 times increased risk for residual instability and graft rupture compared to patients with a DLFNS ≤ 1.8 mm.Conclusions: A DLFNS > 1.8 mm could be a clinically relevant diagnostic tool for identifying a concomitant ACL/ALL rupture with high sensitivity and PPV. Patients with a DLFNS > 1.8 mm should be carefully evaluated for clinical and radiological signs of a concomitant ACL/ALL rupture and treated when needed with a combined intra‐articular ACL reconstruction and extra‐articular tenodesis to avoid a residual rotational instability and ACL graft rupture.Level of evidence: III.
- 24 September 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (6) , 1968-1976
The deep lateral femoral notch sign: a reliable diagnostic tool in identifying a concomitant anterior cruciate and anterolateral ligament injury
Purpose: The aim of the present study was to investigate the validity and reliability of the deep lateral femoral notch sign (DLFNS) in identifying a concomitant anterior cruciate ligament (ACL)/anterolateral ligament (ALL) rupture and predicting the clinical outcomes following an anatomical single‐bundle ACL reconstruction. It was hypothesized that patients with a concomitant ACL/ALL rupture would have an increased DLFNS compared to patients without a concomitant ACL/ALL rupture.Methods: The lateral preoperative radiographs and MRI images of 100 patients with an ACL rupture and 100 control subjects were evaluated for the presence of a DLFNS and ACL/ALL rupture, respectively. The patients were evaluated clinically preoperatively and at a minimum 1 year following the ACL reconstruction. A receiver operator curve (ROC) analysis was performed to define the optimal cut‐off value of the DLFNS for identifying a concomitant ACL/ALL injury. The relative risk (RR) was also calculated to determine whether the presence of the DLFNS was a risk factor for residual instability or ACL graft rupture following an ACL reconstruction.Results: The prevalence of DLFNS was 52% in the ACL‐ruptured patients and 15% in the control group. At a minimum 1‐year follow‐up, 35% (6/17) of the patients with DLFNS > 1.8 mm complained of persistent instability, and an MRI evaluation demonstrated a graft re‐rupture rate of 12% (2/17). In patients with a DLFNS < 1.8 mm, 8% (7/83) reported a residual instability, and the graft rupture rate was 2.4% (2/83). A DLFNS > 1.8 mm demonstrated a sensitivity of 89%, a specificity of 95%, a negative predictive value of 98%, and a positive predictive value of 89% in identifying a concomitant ACL/ALL rupture. Patients with a DLFNS > 1.8 mm had 4.2 times increased risk for residual instability and graft rupture compared to patients with a DLFNS ≤ 1.8 mm.Conclusions: A DLFNS > 1.8 mm could be a clinically relevant diagnostic tool for identifying a concomitant ACL/ALL rupture with high sensitivity and PPV. Patients with a DLFNS > 1.8 mm should be carefully evaluated for clinical and radiological signs of a concomitant ACL/ALL rupture and treated when needed with a combined intra‐articular ACL reconstruction and extra‐articular tenodesis to avoid a residual rotational instability and ACL graft rupture.Level of evidence: III.