NZNan Zheng

Nan Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nan Zheng has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Digging into the Cause of Abnormal Patellar Kinematics After Open-Wedge High Tibial Osteotomy via a Quantitative Study on In Vivo Soft Tissue Functional Changes

    by Zheng Jiang, Nan Zheng, Axiang He, Guoqiang Zhang, Weiming Lin, Yang Qu, Tsung-Yuan Tsai, Wanjun Liu, Yanjie Mao

    The biomechanical mechanism of postoperative patellofemoral joint (PFJ) complications after open-wedge high tibial osteotomy (OWHTO) has not been investigated. This study was to determine the length changes in the patellar tendon (PT), medial patellotibial ligament (MPTL), medial patellofemoral ligament (MPFL), and quadriceps moment arm (QMA) during staircase motion before and after OWHTO. Computed tomography (CT) scans of 15 patients’ lower extremities were used to reconstruct three-dimensional models, and magnetic resonance imaging (MRI) of the knee and hip joints was used to mark the soft tissue footprints. Then, such soft tissue lengths were quantified by a dual fluoroscopic imaging system (DFIS). Additionally, function scores were used to assess patient outcome changes. The results showed that there was a contraction of the PT after OWHTO due to its adhesion to the osteotomy site, causing PT length to be negatively correlated to the open-wedge angle. In addition, the shortening of the MPTL and QMA caused patellar instability and an imbalance in the strength of the lower extremities. Additionally, most knee function scores improved after OWHTO, except the Feller scores. Multiple methods should be considered to optimize surgical procedures, postoperative rehabilitation, and physical therapy.


  • Open Access

    Development and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force

    by Yangyang Yang, Yufan Wang, Nan Zheng, Rongshan Cheng, Diyang Zou, Jie Zhao, Tsung-Yuan Tsai

    In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from −6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.


  • Open Access

    Larger Medial Contact Area and More Anterior Contact Position in Medial-Pivot than Posterior-Stabilized Total Knee Arthroplasty during In-Vivo Lunge Activity

    by Diyang Zou, Jiaqi Tan, Nan Zheng, Zhi Ling, Wanxin Yu, Ming Han Lincoln Liow, Yunsu Chen, Tsung-Yuan Tsai

    This study aimed to compare the in-vivo kinematics and articular contact status between medial-pivot total knee arthroplasty (MP-TKA) and posterior stabilized (PS) TKA during weight-bearing single-leg lunge. 16 MP-TKA and 12 PS-TKA patients performed bilateral single-leg lunges under dual fluoroscopy surveillance to determine the in-vivo six degrees-of-freedom knee kinematics. The closest point between the surface models of the femoral condyle and the polyethylene insert was used to determine the contact position and area. The nonparametric statistics analysis was performed to test the symmetry of the kinematics between MP-TKA and PS-TKA. PS-TKA demonstrated a significantly greater range of AP translation than MP-TKA during high flexion (p = 0.0002). Both groups showed a significantly greater range of lateral compartment posterior translation with medial pivot rotation. The contact points of PS-TKA were located significantly more posterior than MP-TKA in both medial (10°–100°) and lateral (5°–40°, 55°–100°) compartments (p < 0.0500). MP-TKA had a significantly larger contact area in the medial compartment than in the lateral compartment. In contrast, no significant differences were observed in PS-TKA. The present study revealed no significant differences in clinical outcomes between the MP and PS groups. The PS-TKA demonstrated significantly more posterior translations than MP-TKA at high flexion. The contact points are located more posteriorly in PS-TKA compared with MP-TKA. A larger contact area and medial pivot pattern during high flexion in MP-TKA indicated that MP-TKA provides enhanced medial pivot rotation.