R. A. Hakim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
R. A. Hakim has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
M. S. Alama
King Abdulaziz University
1 shared publication- Mohammed Sohaib Alama
Civil Engineering Department, Faculty of Engineering, King Abdulaziz University, Jeddah, Saudi Arabia
1 shared publication S. A. Ashour
King Abdulaziz University
1 shared publication- S. A. Ashour
Civil Engineering Department, King Abdul-Aziz University, Jeddah, Saudi Arabia
1 shared publication
Latest Publications
- 4 October 2014
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 39 (11) , 7691-7699
Seismic Assessment of RC Building According to ATC 40, FEMA 356 and FEMA 440
- 4 October 2014
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 39 (11) , 7691-7699
Seismic Assessment of RC Building According to ATC 40, FEMA 356 and FEMA 440
- Open Access
- 14 June 2014
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 4 (3) , 631-635
Seismic Assessment of an RC Building Using Pushover Analysis
Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.
- 14 June 2014
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 4 (3) , 631-635
Open AccessSeismic Assessment of an RC Building Using Pushover Analysis
Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.