Mohammed Sohaib Alama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammed Sohaib Alama has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Made Suangga
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, 11480, Indonesia
1 shared publication - Militia Keintjem
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia
1 shared publication - R. A. Hakim
King Abdulaziz University
1 shared publication - Riza Suwondo
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia
1 shared publication - S. A. Ashour
Civil Engineering Department, King Abdul-Aziz University, Jeddah, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 26317-26322
Comparative Seismic Analysis of Multi-Story RC Buildings under the Indonesian Seismic Code Using Static Equivalent and Response Spectrum Methods
Indonesia’s geographic position along the Pacific Ring of Fire exposes it to frequent and potentially devastating seismic events, necessitating reliable analytical methods for earthquake-resistant structural designs. While seismic design codes such as the Indonesian Seismic Code permit both linear static and dynamic analyses, the practical differences between the Static Equivalent Method (SEM) and Response Spectrum Analysis (RSA) remain insufficiently explored for multi-story Reinforced Concrete (RC) buildings. This study addresses this gap by comparing the seismic responses predicted by SEM and RSA for regular RC moment-resisting frame structures with two, four, six, and eight stories. Structural modeling and analysis were conducted using ETABS, and the evaluation focused on the key response parameters, including the total base shear and story-level seismic force distribution. The results indicate that RSA consistently predicts a higher base shear than SEM, with the discrepancy increasing as the building height increases. Additionally, the RSA captures a more dynamic and non-uniform seismic force distribution along the height, particularly in mid-level stories where the higher-mode effects become significant. These findings highlight the limitations of SEM in representing the dynamic behavior of taller structures and emphasize the suitability of RSA for more accurate seismic demand estimation in the performance-based design of mid- to high-rise RC buildings in seismically active regions.
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 26317-26322
Open AccessComparative Seismic Analysis of Multi-Story RC Buildings under the Indonesian Seismic Code Using Static Equivalent and Response Spectrum Methods
Indonesia’s geographic position along the Pacific Ring of Fire exposes it to frequent and potentially devastating seismic events, necessitating reliable analytical methods for earthquake-resistant structural designs. While seismic design codes such as the Indonesian Seismic Code permit both linear static and dynamic analyses, the practical differences between the Static Equivalent Method (SEM) and Response Spectrum Analysis (RSA) remain insufficiently explored for multi-story Reinforced Concrete (RC) buildings. This study addresses this gap by comparing the seismic responses predicted by SEM and RSA for regular RC moment-resisting frame structures with two, four, six, and eight stories. Structural modeling and analysis were conducted using ETABS, and the evaluation focused on the key response parameters, including the total base shear and story-level seismic force distribution. The results indicate that RSA consistently predicts a higher base shear than SEM, with the discrepancy increasing as the building height increases. Additionally, the RSA captures a more dynamic and non-uniform seismic force distribution along the height, particularly in mid-level stories where the higher-mode effects become significant. These findings highlight the limitations of SEM in representing the dynamic behavior of taller structures and emphasize the suitability of RSA for more accurate seismic demand estimation in the performance-based design of mid- to high-rise RC buildings in seismically active regions.
- Open Access
- 14 June 2014
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 4 (3) , 631-635
Seismic Assessment of an RC Building Using Pushover Analysis
Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.
- 14 June 2014
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 4 (3) , 631-635
Open AccessSeismic Assessment of an RC Building Using Pushover Analysis
Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.