Jake Stuchbury-Wass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jake Stuchbury-Wass has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Cecilia Mascolo
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
11 shared publications - Dong Ma
University of Cambridge, Cambridge, United Kingdom
9 shared publications - Qiang Yang
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
9 shared publications - Yang Liu
Florida State University, Tallahassee, USA
9 shared publications - Kayla-Jade Butkow
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
8 shared publications - Mathias Ciliberto
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
5 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-25
ImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-25
Open AccessImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- Open Access
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 121-125
Towards Personalised DPOAE Protocols: Bayesian Optimisation of Secondary Stimulus Levels
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 121-125
Open AccessTowards Personalised DPOAE Protocols: Bayesian Optimisation of Secondary Stimulus Levels
- Open Access
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 90-91
Unlocking Human Movement: Detailed Gait and Impact Assessment from Consumer Earable Devices
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 90-91
Open AccessUnlocking Human Movement: Detailed Gait and Impact Assessment from Consumer Earable Devices
- Open Access
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-41
A Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-41
Open AccessA Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- Open Access
- 25 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 103-108
EarCalo: Earable-Based Energy Expenditure Estimation While Running
Accurately estimating energy expenditure (EE) is crucial for understanding exercise efficiency, managing fitness goals, and monitoring health conditions. Existing wearable systems either rely primarily on heart rate and motion sensors, resulting in unsatisfactory accuracy, or require bulky setups such as thermal cameras to improve performance by integrating more physiological information, which limits real-world applicability. We present EarCalo, an earable-based system that leverages in-ear audio sensing to estimate EE during running. The system extracts airflow-induced acoustic variations within the ear canal and employs a deep neural network to translate these subtle in-ear sound dynamics into EE estimates. The key insight is that in-ear acoustic signals can capture multiple physiological factors such as breathing and cardiovascular activity, while also reflecting motion-related cues like running intensity. These rich acoustic cues are closely related to EE and provide a unified sensing modality for estimation. We evaluated EarCalo on 21 participants running at varying speeds using a mixed-user setting. EarCalo achieved a mean absolute error (MAE) of 0.67 kcal/min, a mean absolute percentage error (MAPE) of 11.98%, and a Pearson correlation of 0.945, which achieves accuracy close to established physiological standards. This work represents an early step toward practical and personalized earable-based EE estimation in everyday settings.
- 25 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 103-108
Open AccessEarCalo: Earable-Based Energy Expenditure Estimation While Running
Accurately estimating energy expenditure (EE) is crucial for understanding exercise efficiency, managing fitness goals, and monitoring health conditions. Existing wearable systems either rely primarily on heart rate and motion sensors, resulting in unsatisfactory accuracy, or require bulky setups such as thermal cameras to improve performance by integrating more physiological information, which limits real-world applicability. We present EarCalo, an earable-based system that leverages in-ear audio sensing to estimate EE during running. The system extracts airflow-induced acoustic variations within the ear canal and employs a deep neural network to translate these subtle in-ear sound dynamics into EE estimates. The key insight is that in-ear acoustic signals can capture multiple physiological factors such as breathing and cardiovascular activity, while also reflecting motion-related cues like running intensity. These rich acoustic cues are closely related to EE and provide a unified sensing modality for estimation. We evaluated EarCalo on 21 participants running at varying speeds using a mixed-user setting. EarCalo achieved a mean absolute error (MAE) of 0.67 kcal/min, a mean absolute percentage error (MAPE) of 11.98%, and a Pearson correlation of 0.945, which achieves accuracy close to established physiological standards. This work represents an early step toward practical and personalized earable-based EE estimation in everyday settings.
- Open Access
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (5) , 1-10
Ear-Worn Inertial Sensors Can Predict Gait Metrics and Reconstruct Vertical Ground Reaction Force Curves During Running
Ear-worn wearables (aka: earbuds, hearables, or earables) are commonly used by runners for entertainment, and many modern devices also include inertial sensors for user interaction. We propose harnessing the technology embedded in earbuds to capture fundamental aspects of running mechanics and make them available to the wider community of users, outside a lab setting. While other wearables such as insoles or ankle-/sacrum-mounted inertial measurement units have already been presented, ear-worn devices may have a better potential for adoption and therefore offer an optimal compromise between validity of running gait analysis and usability. Thirty healthy participants (18 males, 12 females) ran on an instrumented treadmill (54,000 gait cycles) and floor-mounted force plates (2800 gait cycles) at a variety of speeds. Building on the information brought about by the vibrations transmitted to, and motion of, the head, we devised a gait event detection algorithm and a regression model to predict vertical ground reaction force waveforms. The validation of outcomes against quantities from force plates shows an average mean absolute percentage error of 4.8% on temporal metrics and 9.0% on scalar ground reaction force derived metrics. Additionally, the model tracks the full vertical ground reaction force curve well, achieving an normalized root mean square error of 11.1% on unseen participants. Overall, we show comparable accuracy from an ear-worn consumer device in temporal and kinetic gait parameter estimation to specialist devices, paving the way for accessible running gait monitoring.
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (5) , 1-10
Open AccessEar-Worn Inertial Sensors Can Predict Gait Metrics and Reconstruct Vertical Ground Reaction Force Curves During Running
Ear-worn wearables (aka: earbuds, hearables, or earables) are commonly used by runners for entertainment, and many modern devices also include inertial sensors for user interaction. We propose harnessing the technology embedded in earbuds to capture fundamental aspects of running mechanics and make them available to the wider community of users, outside a lab setting. While other wearables such as insoles or ankle-/sacrum-mounted inertial measurement units have already been presented, ear-worn devices may have a better potential for adoption and therefore offer an optimal compromise between validity of running gait analysis and usability. Thirty healthy participants (18 males, 12 females) ran on an instrumented treadmill (54,000 gait cycles) and floor-mounted force plates (2800 gait cycles) at a variety of speeds. Building on the information brought about by the vibrations transmitted to, and motion of, the head, we devised a gait event detection algorithm and a regression model to predict vertical ground reaction force waveforms. The validation of outcomes against quantities from force plates shows an average mean absolute percentage error of 4.8% on temporal metrics and 9.0% on scalar ground reaction force derived metrics. Additionally, the model tracks the full vertical ground reaction force curve well, achieving an normalized root mean square error of 11.1% on unseen participants. Overall, we show comparable accuracy from an ear-worn consumer device in temporal and kinetic gait parameter estimation to specialist devices, paving the way for accessible running gait monitoring.
- Open Access
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-22
HearForce: Force Estimation for Manual Toothbrushing with Earables
Excessive tooth brushing force can contribute to oral health issues such as gum recession and bleeding. While some electric toothbrushes offer force feedback, manual toothbrushes remain widely used due to their affordability and accessibility but do not give this sort of information to users. Therefore, they often lack awareness of the force they apply while brushing. In this paper, we introduce HearForce, the first system to estimate tooth brushing force from manual toothbrushing using widely available earbuds. Unlike existing solutions that require significant modifications to toothbrushes, HearForce leverages in-ear microphones on commercial earbuds to capture bone-conducted toothbrushing sound propagating from the oral cavity to the ear canals. Our key insight is that variations in brushing force modulate these toothbrushing sounds due to the friction effect, allowing us to infer force levels through deep learning. However, individual habitual and anatomical differences introduce significant challenges for force estimation. To mitigate this, we propose a self-supervised representation learning network with a cross-attention mechanism to suppress user-dependent variability and a heuristic calibration strategy to adapt the model to different brushing habits. Through extensive evaluation, HearForce demonstrates force estimation capabilities with a Mean Absolute Error (MAE) of 37.3g in user-independent settings, corresponding to 11.4% of the typical force dynamic range. Our study makes the first step in the use of everyday earbuds for manual toothbrushing force monitoring, paving the way for accessible solutions to improve brushing habits for manual toothbrush users globally.
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-22
Open AccessHearForce: Force Estimation for Manual Toothbrushing with Earables
Excessive tooth brushing force can contribute to oral health issues such as gum recession and bleeding. While some electric toothbrushes offer force feedback, manual toothbrushes remain widely used due to their affordability and accessibility but do not give this sort of information to users. Therefore, they often lack awareness of the force they apply while brushing. In this paper, we introduce HearForce, the first system to estimate tooth brushing force from manual toothbrushing using widely available earbuds. Unlike existing solutions that require significant modifications to toothbrushes, HearForce leverages in-ear microphones on commercial earbuds to capture bone-conducted toothbrushing sound propagating from the oral cavity to the ear canals. Our key insight is that variations in brushing force modulate these toothbrushing sounds due to the friction effect, allowing us to infer force levels through deep learning. However, individual habitual and anatomical differences introduce significant challenges for force estimation. To mitigate this, we propose a self-supervised representation learning network with a cross-attention mechanism to suppress user-dependent variability and a heuristic calibration strategy to adapt the model to different brushing habits. Through extensive evaluation, HearForce demonstrates force estimation capabilities with a Mean Absolute Error (MAE) of 37.3g in user-independent settings, corresponding to 11.4% of the typical force dynamic range. Our study makes the first step in the use of everyday earbuds for manual toothbrushing force monitoring, paving the way for accessible solutions to improve brushing habits for manual toothbrush users globally.
- Open Access
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-29
EarMeter: Continuous Respiration Volume Monitoring with Earables
Respiration volume, i.e., the amount of air inhaled/exhaled during breathing, is a critical measure for health and fitness in daily life, such as helping optimize sports performance, tracking wellness, and early anomaly detection. Current continuous respiration volume monitoring solutions either require specialized and cumbersome instrumentation setup (e.g., RF transceivers), or rely on customized and non-portable wearables (e.g., masks and chest straps), limiting their usage scenarios. In this paper, we introduce EarMeter, the first continuous respiration volume monitoring system that utilizes in-ear microphones on earbuds to seamlessly track respiration volume across varying breathing intensities, making the measurement more accessible in diverse scenarios. The underlying idea is that breathing sounds, which correlate with breathing volume, can propagate through the body to the ear canals, where they are captured by in-ear microphones. To achieve this, we propose a deep-learning approach to address four unique challenges: limited labeled data, faint breathing sounds, interference from footsteps, and generalization to unseen users. Our approach features fine-tuning an audio encoder pretrained on a broad range of audio datasets, knowledge transfer from high-quality nose audio, performance boosting with breathing-heartbeat coupling, and alignment of both earphone channels with normalization. Extensive experiments under the Leave-One-Subject-Out (LOSO) setting across varying breathing intensities demonstrate the effectiveness of EarMeter, with an average Mean Absolute Percentage Error (MAPE) of 18.19%, meeting the clinically required standard of 20%.
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-29
Open AccessEarMeter: Continuous Respiration Volume Monitoring with Earables
Respiration volume, i.e., the amount of air inhaled/exhaled during breathing, is a critical measure for health and fitness in daily life, such as helping optimize sports performance, tracking wellness, and early anomaly detection. Current continuous respiration volume monitoring solutions either require specialized and cumbersome instrumentation setup (e.g., RF transceivers), or rely on customized and non-portable wearables (e.g., masks and chest straps), limiting their usage scenarios. In this paper, we introduce EarMeter, the first continuous respiration volume monitoring system that utilizes in-ear microphones on earbuds to seamlessly track respiration volume across varying breathing intensities, making the measurement more accessible in diverse scenarios. The underlying idea is that breathing sounds, which correlate with breathing volume, can propagate through the body to the ear canals, where they are captured by in-ear microphones. To achieve this, we propose a deep-learning approach to address four unique challenges: limited labeled data, faint breathing sounds, interference from footsteps, and generalization to unseen users. Our approach features fine-tuning an audio encoder pretrained on a broad range of audio datasets, knowledge transfer from high-quality nose audio, performance boosting with breathing-heartbeat coupling, and alignment of both earphone channels with normalization. Extensive experiments under the Leave-One-Subject-Out (LOSO) setting across varying breathing intensities demonstrate the effectiveness of EarMeter, with an average Mean Absolute Percentage Error (MAPE) of 18.19%, meeting the clinically required standard of 20%.
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 1297-1300
OpenBrush: An Open-Source Manual Toothbrush for Force and Motion Sensing
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 1297-1300
Open AccessOpenBrush: An Open-Source Manual Toothbrush for Force and Motion Sensing
- Open Access
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-19
SmarTeeth: Augmenting Manual Toothbrushing with In-ear Microphones
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-19
Open AccessSmarTeeth: Augmenting Manual Toothbrushing with In-ear Microphones