Kathrin Nuelle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathrin Nuelle has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jessica Burgner-Kahrs
University of Toronto
3 shared publications - Sven Lilge
Continuum Robotics Laboratory, Department of Mathematical and Computational Sciences, University of Toronto, Mississauga, ON, Canada
3 shared publications Tobias Ortmaier
3 shared publicationsJens Kotlarski
Institute of Mechatronic Systems, Leibniz Universität Hannover, Germany
2 shared publications- Svenja Tappe
Gottfried Wilhelm Leibniz Universität Hannover
2 shared publications Andrej Dick
Institute of Mechatronic Systems, Leibniz Universität Hannover, Germany
1 shared publication
Latest Publications
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3252-3270
Parallel-Continuum Robots: A Survey
Parallel-continuum robots combine the advantages of both parallel and continuum robotics. They offer a compromise between the inherent compliance and slenderness of continuum robots and the high precision and strength of rigid-link parallel robots. Throughout recent years there has been an increasing research interest in these novel architectures, which form closed kinematic chains that feature flexible, continuous links undergoing elastic deformations. As the number of publications in this emerging research field is steadily increasing, this survey paper summarizes and reviews the state of the art in parallel-continuum robots, discussing their design and modeling. A definition and notation for parallel-continuum robots is introduced, allowing for a clear classification. In conclusion, current open research questions and possible applications for such robots are discussed.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3252-3270
Parallel-Continuum Robots: A Survey
Parallel-continuum robots combine the advantages of both parallel and continuum robotics. They offer a compromise between the inherent compliance and slenderness of continuum robots and the high precision and strength of rigid-link parallel robots. Throughout recent years there has been an increasing research interest in these novel architectures, which form closed kinematic chains that feature flexible, continuous links undergoing elastic deformations. As the number of publications in this emerging research field is steadily increasing, this survey paper summarizes and reviews the state of the art in parallel-continuum robots, discussing their design and modeling. A definition and notation for parallel-continuum robots is introduced, allowing for a clear classification. In conclusion, current open research questions and possible applications for such robots are discussed.
- 10 December 2020
- Published by Wiley in Journal of Mechanisms and Robotics
- Vol. 13 (1) , 1-34
Tendon Actuated Continuous Structures in Planar Parallel Robots: A Kinematic Analysis
The use of continuous and flexible structures instead of rigid links and discrete joints is a growing field of robotics research. Recent work focuses on the inclusion of continuous segments in parallel robots to benefit from their structural advantages, such as a high dexterity and compliance. While some applications and designs of these novel parallel continuum robots have been presented, the field remains largely unexplored. Furthermore, an exact quantification of the kinematic advantages and disadvantages when using continuous structures in parallel robots is yet to be performed. In this paper, planar parallel robot designs using tendon actuated continuum robots instead of rigid links and discrete joints are proposed. Using the well-known 3-RRR manipulator as a reference design, two parallel continuum robots are derived. Inverse and differential kinematics of these designs are modeled using constant curvature assumptions, which can be adapted for other actuation mechanisms than tendons. Their kinematic performances are compared to the conventional parallel robot counterpart. On the basis of this comparison, the advantages and disadvantages of using continuous structures in parallel robots are quantified and analyzed. Results show that parallel continuum robots can be kinematic equivalent and exhibit similar kinematic performances in comparison to conventional parallel robots depending on the chosen design.
- 10 December 2020
- Published by Wiley in Journal of Mechanisms and Robotics
- Vol. 13 (1) , 1-34
Tendon Actuated Continuous Structures in Planar Parallel Robots: A Kinematic Analysis
The use of continuous and flexible structures instead of rigid links and discrete joints is a growing field of robotics research. Recent work focuses on the inclusion of continuous segments in parallel robots to benefit from their structural advantages, such as a high dexterity and compliance. While some applications and designs of these novel parallel continuum robots have been presented, the field remains largely unexplored. Furthermore, an exact quantification of the kinematic advantages and disadvantages when using continuous structures in parallel robots is yet to be performed. In this paper, planar parallel robot designs using tendon actuated continuum robots instead of rigid links and discrete joints are proposed. Using the well-known 3-RRR manipulator as a reference design, two parallel continuum robots are derived. Inverse and differential kinematics of these designs are modeled using constant curvature assumptions, which can be adapted for other actuation mechanisms than tendons. Their kinematic performances are compared to the conventional parallel robot counterpart. On the basis of this comparison, the advantages and disadvantages of using continuous structures in parallel robots are quantified and analyzed. Results show that parallel continuum robots can be kinematic equivalent and exhibit similar kinematic performances in comparison to conventional parallel robots depending on the chosen design.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (4) , 5811-5818
Modeling, Calibration, and Evaluation of a Tendon-Actuated Planar Parallel Continuum Robot
In this work, a novel planar parallel continuum robot (PCR) is introduced, consisting of three kinematic chains that are coupled at a triangular end-effector platform and include tendon-actuated continuum segments. The kinematics of the resulting structure is derived by adapting the descriptions for conventional planar parallel manipulators to include constant curvature bending of the utilized continuous segments. To account for friction and non-linear material effects, a datadriven model is used to relate tendon displacements and curvature of the utilized continuum segments. A calibration of the derived kinematic model is conducted to specifically represent the constructed prototype. This includes the calibration of geometric parameters for each kinematic chain and for the end-effector platform. During evaluation, positioning repeatability of 1.0 0.3% in relation to one continuum segment length of the robot, and positioning accuracy of 1.4 0.7%, are achieved. These results are comparable to commonly used kineto-static modeling approaches for PCR. The presented model achieves high path accuracies regarding the robot's end-effector pose in an open-loop control scenario.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (4) , 5811-5818
Modeling, Calibration, and Evaluation of a Tendon-Actuated Planar Parallel Continuum Robot
In this work, a novel planar parallel continuum robot (PCR) is introduced, consisting of three kinematic chains that are coupled at a triangular end-effector platform and include tendon-actuated continuum segments. The kinematics of the resulting structure is derived by adapting the descriptions for conventional planar parallel manipulators to include constant curvature bending of the utilized continuous segments. To account for friction and non-linear material effects, a datadriven model is used to relate tendon displacements and curvature of the utilized continuum segments. A calibration of the derived kinematic model is conducted to specifically represent the constructed prototype. This includes the calibration of geometric parameters for each kinematic chain and for the end-effector platform. During evaluation, positioning repeatability of 1.0 0.3% in relation to one continuum segment length of the robot, and positioning accuracy of 1.4 0.7%, are achieved. These results are comparable to commonly used kineto-static modeling approaches for PCR. The presented model achieves high path accuracies regarding the robot's end-effector pose in an open-loop control scenario.
- 31 October 2018
- Published by Springer Nature
- p. 169-176
Mobile Augmented Reality System for Craftsmen
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 196-201
Force sensing, low-cost manipulator in mobile robotics
The ability to sense tactile feedback is important for many robotic grasping and manipulating tasks. However, common force sensors are expensive. Therefore, we investigate various force measuring principles and review existing sensor concepts for mobile robotic applications. The results lead to a concept of a low-cost, two-finger manipulator with force sensing ability using embedded hall sensors in flexible material. The gripper is produced by rapid prototyping. A calibration method is presented. Furthermore, we evaluate and present the idle state, local sensitivity, and material influence of the two-finger manipulator. As a result, it is possible to successfully handle sensitive objects with the sensitive areas of the fingers, although a bias was measures while handling ferromagnetic materials. With a priori knowledge of the objects, this effect can be compensated.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 196-201
Force sensing, low-cost manipulator in mobile robotics
The ability to sense tactile feedback is important for many robotic grasping and manipulating tasks. However, common force sensors are expensive. Therefore, we investigate various force measuring principles and review existing sensor concepts for mobile robotic applications. The results lead to a concept of a low-cost, two-finger manipulator with force sensing ability using embedded hall sensors in flexible material. The gripper is produced by rapid prototyping. A calibration method is presented. Furthermore, we evaluate and present the idle state, local sensitivity, and material influence of the two-finger manipulator. As a result, it is possible to successfully handle sensitive objects with the sensitive areas of the fingers, although a bias was measures while handling ferromagnetic materials. With a priori knowledge of the objects, this effect can be compensated.
- 26 September 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (3) , 421-436
Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery
Purpose Minimally invasive cochlear implantation is a novel surgical technique which requires highly accurate guidance of a drilling tool along a trajectory from the mastoid surface toward the basal turn of the cochlea. The authors propose a passive, reconfigurable, parallel robot which can be directly attached to bone anchors implanted in a patient’s skull, avoiding the need for surgical tracking systems. Prior to clinical trials, methods are necessary to patient specifically optimize the configuration of the mechanism with respect to accuracy and stability. Furthermore, the achievable accuracy has to be determined experimentally. Methods A comprehensive error model of the proposed mechanism is established, taking into account all relevant error sources identified in previous studies. Two optimization criteria to exploit the given task redundancy and reconfigurability of the passive robot are derived from the model. The achievable accuracy of the optimized robot configurations is first estimated with the help of a Monte Carlo simulation approach and finally evaluated in drilling experiments using synthetic temporal bone specimen. Results Experimental results demonstrate that the bone-attached mechanism exhibits a mean targeting accuracy of \((0.36\pm 0.12)\) mm under realistic conditions. A systematic targeting error is observed, which indicates that accurate identification of the passive robot’s kinematic parameters could further reduce deviations from planned drill trajectories. Conclusion The accuracy of the proposed mechanism demonstrates its suitability for minimally invasive cochlear implantation. Future work will focus on further evaluation experiments on temporal bone specimen.- 26 September 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (3) , 421-436
Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery
Purpose Minimally invasive cochlear implantation is a novel surgical technique which requires highly accurate guidance of a drilling tool along a trajectory from the mastoid surface toward the basal turn of the cochlea. The authors propose a passive, reconfigurable, parallel robot which can be directly attached to bone anchors implanted in a patient’s skull, avoiding the need for surgical tracking systems. Prior to clinical trials, methods are necessary to patient specifically optimize the configuration of the mechanism with respect to accuracy and stability. Furthermore, the achievable accuracy has to be determined experimentally. Methods A comprehensive error model of the proposed mechanism is established, taking into account all relevant error sources identified in previous studies. Two optimization criteria to exploit the given task redundancy and reconfigurability of the passive robot are derived from the model. The achievable accuracy of the optimized robot configurations is first estimated with the help of a Monte Carlo simulation approach and finally evaluated in drilling experiments using synthetic temporal bone specimen. Results Experimental results demonstrate that the bone-attached mechanism exhibits a mean targeting accuracy of \((0.36\pm 0.12)\) mm under realistic conditions. A systematic targeting error is observed, which indicates that accurate identification of the passive robot’s kinematic parameters could further reduce deviations from planned drill trajectories. Conclusion The accuracy of the proposed mechanism demonstrates its suitability for minimally invasive cochlear implantation. Future work will focus on further evaluation experiments on temporal bone specimen.