Pratyasa Bhui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pratyasa Bhui has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Kotakonda Chakravarthi
Department of Electrical Engineering, Indian Institute of Technology Dharwad, Dharwad, Karnataka, India
4 shared publications - Ajul Dinesh
Inria, University of Lille, CNRS, UMR 9189–CRIStAL Lille France
3 shared publications - Ameer Kalandar Mulla
Department of Electrical, Electronics and Communication Engineering, Indian Institute of Technology Dharwad, Dharwad, India
3 shared publications - Animesh Kumar Sahoo
Department of Electrical, Electronics, and Communication Engineering, IIT Dharwad Karnataka
2 shared publications - Bikash Chandra Pal
Imperial College London
2 shared publications - Faheem Ul Haq
Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.
2 shared publications
Latest Publications
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2150-2160
Robust Decentralized Dissipative Controller-Based Tie-Line Power Flow Regulation in Multi-Area Power System Networks
Deregulation, real-time markets, contingencies, and increased renewable energy integration often lead to congestion in power system networks. Traditional optimal power flow (OPF)-based methods for congestion mitigation are typically too slow for real-time power flow regulation during contingencies, resulting in conservative system operation. Robust controllers offer a viable alternative by regulating line flows within short timeframes. However, existing observer-based centralized controllers are often unsuitable for large-scale grids due to their reliance on state estimation and system-wide data. To address this, the paper proposes a measurement-based decentralized robust control strategy for power flow regulation in tie-lines. Large grids are partitioned into multiple control areas, each modeled as a polytopic uncertain system with external interconnections. Robust static output feedback controllers are then designed for each area to regulate intra-area and inter-area tie-line flows below specified thresholds. These decentralized controllers use dissipativity theory as a robustness measure and are synthesized using linear matrix inequalities (LMIs), relying solely on local data from each control area. For large-scale networks, the proposed controller can be deployed in real time within each control area by re-dispatching generators and battery energy storage systems (BESSs), using synchrophasor measurements from tie-lines. The paper also provides a theoretical analysis of dissipativity and asymptotic stability for the overall interconnected system. The effectiveness of the proposed decentralized robust controller is demonstrated through simulations on a 16-machine, 68-bus test system and Kundur’s 4-machine, 2-area test system, showing its capability to deliver fast and automatic corrective actions for real-time power flow regulation.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2150-2160
Robust Decentralized Dissipative Controller-Based Tie-Line Power Flow Regulation in Multi-Area Power System Networks
Deregulation, real-time markets, contingencies, and increased renewable energy integration often lead to congestion in power system networks. Traditional optimal power flow (OPF)-based methods for congestion mitigation are typically too slow for real-time power flow regulation during contingencies, resulting in conservative system operation. Robust controllers offer a viable alternative by regulating line flows within short timeframes. However, existing observer-based centralized controllers are often unsuitable for large-scale grids due to their reliance on state estimation and system-wide data. To address this, the paper proposes a measurement-based decentralized robust control strategy for power flow regulation in tie-lines. Large grids are partitioned into multiple control areas, each modeled as a polytopic uncertain system with external interconnections. Robust static output feedback controllers are then designed for each area to regulate intra-area and inter-area tie-line flows below specified thresholds. These decentralized controllers use dissipativity theory as a robustness measure and are synthesized using linear matrix inequalities (LMIs), relying solely on local data from each control area. For large-scale networks, the proposed controller can be deployed in real time within each control area by re-dispatching generators and battery energy storage systems (BESSs), using synchrophasor measurements from tie-lines. The paper also provides a theoretical analysis of dissipativity and asymptotic stability for the overall interconnected system. The effectiveness of the proposed decentralized robust controller is demonstrated through simulations on a 16-machine, 68-bus test system and Kundur’s 4-machine, 2-area test system, showing its capability to deliver fast and automatic corrective actions for real-time power flow regulation.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 516-526
Experiences With Controlled Islanding and Relay Coordination in Lalitpur Power System, India
The formation of a power island, encompassing generating plants and nearby critical loads, is a strategy employed to maintain the operation of generating plants and the supply of power to essential services during potential blackouts. This paper presents a robust frequency stabilization strategy for such islands during blackouts in the main grid. The proposed methodology includes: (i) a three-stage under-frequency load shedding (UFLS) scheme that disconnects loads in large blocks to limit frequency decline; (ii) reconnection of shedded loads in smaller blocks in case of frequency rise after load shedding to maintain generationload balance; and (iii) a selective generator tripping scheme based on the estimated time to critical frequency, improving over traditional frequency or ROCOF-based methods. Load shedding locations are selected using voltage security criteria, and the entire protection scheme operates using only local measurements, removing reliance on communication infrastructure. The relay settings were tested in PSS/E for system data of Agra-Lalitpur region of Indian grid including renewables for varying operating conditions. It was also found that with grid supporting renewables, the frequency nadir improves with increasing renewables while frequency droop does not have much impact. The results have been shared with, and accepted by, the utility for potential implementation in the future.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 516-526
Experiences With Controlled Islanding and Relay Coordination in Lalitpur Power System, India
The formation of a power island, encompassing generating plants and nearby critical loads, is a strategy employed to maintain the operation of generating plants and the supply of power to essential services during potential blackouts. This paper presents a robust frequency stabilization strategy for such islands during blackouts in the main grid. The proposed methodology includes: (i) a three-stage under-frequency load shedding (UFLS) scheme that disconnects loads in large blocks to limit frequency decline; (ii) reconnection of shedded loads in smaller blocks in case of frequency rise after load shedding to maintain generationload balance; and (iii) a selective generator tripping scheme based on the estimated time to critical frequency, improving over traditional frequency or ROCOF-based methods. Load shedding locations are selected using voltage security criteria, and the entire protection scheme operates using only local measurements, removing reliance on communication infrastructure. The relay settings were tested in PSS/E for system data of Agra-Lalitpur region of Indian grid including renewables for varying operating conditions. It was also found that with grid supporting renewables, the frequency nadir improves with increasing renewables while frequency droop does not have much impact. The results have been shared with, and accepted by, the utility for potential implementation in the future.
- Open Access
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 66700-66713
Injection Sensitivity-Based Damping Improvement Model Using V2G and Cooperative Game Theory
With growing concerns about global climate change, the traditional utility grid is transitioning towards cleaner and greener energy generation through renewable energy resources. However, integrating these renewable resources into the utility grid presents significant challenges, adding operational complexities such as low inertia, intermittent generation, and locational inflexibility. Among these, locational inflexibility affects the damping of grid oscillations, particularly low-frequency electromechanical ones. Poorly damped oscillations can lead to reduced Area Transfer Capability (ATC), malfunctioning of protection devices due to erratic power swings, and in the worst case, large-scale outages and blackouts within the power network. This paper proposes a solution to improve the damping of oscillations by introducing an active power injection sensitivity-based damping enhancement using Plug-in Electric Vehicles (PEVs). A cooperative game-theoretic approach is employed to balance the interests of both the Grid and the PEVs while addressing the critical issue of maintaining the oscillation damping factor within a desirable range for secure grid operation. The effectiveness of the proposed method was validated using the standard IEEE 16-Machine 68-Bus test system, as well as a modified version of this test bed. The modification involved integrating wind energy to assess the performance of the proposed method under the influence of renewable energy sources. This adjustment enabled the method to effectively capture scenarios ranging from conventional power grids with minimal renewable integration to modern power systems with high levels of renewable energy integration. The results demonstrate that the method can significantly improve the damping of inter-area oscillations in both scenarios.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 66700-66713
Open AccessInjection Sensitivity-Based Damping Improvement Model Using V2G and Cooperative Game Theory
With growing concerns about global climate change, the traditional utility grid is transitioning towards cleaner and greener energy generation through renewable energy resources. However, integrating these renewable resources into the utility grid presents significant challenges, adding operational complexities such as low inertia, intermittent generation, and locational inflexibility. Among these, locational inflexibility affects the damping of grid oscillations, particularly low-frequency electromechanical ones. Poorly damped oscillations can lead to reduced Area Transfer Capability (ATC), malfunctioning of protection devices due to erratic power swings, and in the worst case, large-scale outages and blackouts within the power network. This paper proposes a solution to improve the damping of oscillations by introducing an active power injection sensitivity-based damping enhancement using Plug-in Electric Vehicles (PEVs). A cooperative game-theoretic approach is employed to balance the interests of both the Grid and the PEVs while addressing the critical issue of maintaining the oscillation damping factor within a desirable range for secure grid operation. The effectiveness of the proposed method was validated using the standard IEEE 16-Machine 68-Bus test system, as well as a modified version of this test bed. The modification involved integrating wind energy to assess the performance of the proposed method under the influence of renewable energy sources. This adjustment enabled the method to effectively capture scenarios ranging from conventional power grids with minimal renewable integration to modern power systems with high levels of renewable energy integration. The results demonstrate that the method can significantly improve the damping of inter-area oscillations in both scenarios.
- Open Access
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 58870-58886
Overcurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults
The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to a) ensure maximum fault current utilization and b) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposedUNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 58870-58886
Open AccessOvercurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults
The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to a) ensure maximum fault current utilization and b) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposedUNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.
- Open Access
- 8 December 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 156
Robust control for line power flow tracking in power systems- 8 December 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 156
Open AccessRobust control for line power flow tracking in power systems - 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (2) , 3349-3360
Robust Guaranteed Cost Output Feedback Control for Real-Time Congestion Management
This article proposes an approach for line power flow regulation through a robust guaranteed cost output feedback controller to mitigate the congestion in power systems. Using the synchrophasor measurements from the lines, the controller regulates the power flows at a specified thermal limit or any other given security limit by re-dispatching the selected generators and Battery Energy Storage Systems (BESSs) in real time. Linear Matrix Inequality (LMI) conditions for robust controller design are given with the uncertain linearized models to satisfy finite $ \mathcal {L}_{2}$ gain property of the system to worst-case external disturbances. Further, a min-max controller is designed to minimize the upper bound on the cost associated with the considered disturbance attenuation performance by solving an optimization problem. The efficacy and applicability of the proposed control scheme in regulating line power flows and mitigating congestion are demonstrated with extensive simulations on Kundur's 4-machine 2-area test system and a 16-machine 68-bus test system. It is shown that the designed controller can regulate line power flows within 40-60 s, which is fast enough to avoid overheating transmission lines, thereby improving the system's robustness.
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (2) , 3349-3360
Robust Guaranteed Cost Output Feedback Control for Real-Time Congestion Management
This article proposes an approach for line power flow regulation through a robust guaranteed cost output feedback controller to mitigate the congestion in power systems. Using the synchrophasor measurements from the lines, the controller regulates the power flows at a specified thermal limit or any other given security limit by re-dispatching the selected generators and Battery Energy Storage Systems (BESSs) in real time. Linear Matrix Inequality (LMI) conditions for robust controller design are given with the uncertain linearized models to satisfy finite $ \mathcal {L}_{2}$ gain property of the system to worst-case external disturbances. Further, a min-max controller is designed to minimize the upper bound on the cost associated with the considered disturbance attenuation performance by solving an optimization problem. The efficacy and applicability of the proposed control scheme in regulating line power flows and mitigating congestion are demonstrated with extensive simulations on Kundur's 4-machine 2-area test system and a 16-machine 68-bus test system. It is shown that the designed controller can regulate line power flows within 40-60 s, which is fast enough to avoid overheating transmission lines, thereby improving the system's robustness.
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (2) , 4240-4251
Real Time Line Power Flow Control Using Model Agnostic Controller
This paper addresses the challenge of mitigating line overloading/congestion caused by renewable penetration and contingencies. Traditional methods of mitigating overloading involve generation rescheduling in tertiary dispatch every 5-30 minutes. This approach is generally based on forecasted load and generation, and not effective in real-time corrective actions. The paper introduces a model-free Neuro Predictive Controller (NPC) that can map line power flows to the inputs of dispatching resources such as generators and/or battery energy storage systems. The NPC receives synchrophasor measurement of line power flows and generates control inputs (i.e., set points) to generators and/or battery energy storage systems. The controller does not require frequent update of the system model. The efficacy of the controller was tested on 16-machine 68-bus test system and the Indian grid for various scenarios, such as line outage, generator outage, variable renewable generation, and load change. The proposed controller demonstrated better performance as compared to the existing controllers. Upon successful implementation, the controller can regulate line flow in less than 60 seconds, allowing the lines to operate closer to the thermal limit and resolve limit violations due to contingencies and variable renewable generation in real-time.
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (2) , 4240-4251
Real Time Line Power Flow Control Using Model Agnostic Controller
This paper addresses the challenge of mitigating line overloading/congestion caused by renewable penetration and contingencies. Traditional methods of mitigating overloading involve generation rescheduling in tertiary dispatch every 5-30 minutes. This approach is generally based on forecasted load and generation, and not effective in real-time corrective actions. The paper introduces a model-free Neuro Predictive Controller (NPC) that can map line power flows to the inputs of dispatching resources such as generators and/or battery energy storage systems. The NPC receives synchrophasor measurement of line power flows and generates control inputs (i.e., set points) to generators and/or battery energy storage systems. The controller does not require frequent update of the system model. The efficacy of the controller was tested on 16-machine 68-bus test system and the Indian grid for various scenarios, such as line outage, generator outage, variable renewable generation, and load change. The proposed controller demonstrated better performance as compared to the existing controllers. Upon successful implementation, the controller can regulate line flow in less than 60 seconds, allowing the lines to operate closer to the thermal limit and resolve limit violations due to contingencies and variable renewable generation in real-time.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (3) , 2189-2203
Real Time Congestion Management Using Generation Re-Dispatch: Modeling and Controller Design
Increased power demand, poor transmission infrastructure, and uncertain renewable generation cause congestion in the power network. Traditionally network congestion is cleared by the system operator by rescheduling generators once every 5-20 min, which may be too slow for grids with renewable generation. Network congestion can be cleared automatically and immediately by a controller. The controller can obtain synchrophasor measurements of line power flow and maintain it at the desired value by controlling some generators and battery energy storage systems (BESS) in real-time. This paper develops an accurate dynamic model of the line power flow. A disturbance compensation based Model Predictive Control (MPC) strategy is proposed to regulate the line power flow at or below the desired value, e.g., thermal limit, in real-time by re-dispatching some generators and/or BESS’s. The MPC technique considers several realistic constraints such as output and rate limits and active power balance in the network. The control strategy is validated on Kundur 4-machine 2-area and 16-machine 68-bus test systems and shown to have better performance as compared to the existing technique. It has been found out that the proposed controller successfully regulates the line power flow within 20-60s by controlling synchronous generators and within a few seconds by controlling BESS’s.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (3) , 2189-2203
Real Time Congestion Management Using Generation Re-Dispatch: Modeling and Controller Design
Increased power demand, poor transmission infrastructure, and uncertain renewable generation cause congestion in the power network. Traditionally network congestion is cleared by the system operator by rescheduling generators once every 5-20 min, which may be too slow for grids with renewable generation. Network congestion can be cleared automatically and immediately by a controller. The controller can obtain synchrophasor measurements of line power flow and maintain it at the desired value by controlling some generators and battery energy storage systems (BESS) in real-time. This paper develops an accurate dynamic model of the line power flow. A disturbance compensation based Model Predictive Control (MPC) strategy is proposed to regulate the line power flow at or below the desired value, e.g., thermal limit, in real-time by re-dispatching some generators and/or BESS’s. The MPC technique considers several realistic constraints such as output and rate limits and active power balance in the network. The control strategy is validated on Kundur 4-machine 2-area and 16-machine 68-bus test systems and shown to have better performance as compared to the existing technique. It has been found out that the proposed controller successfully regulates the line power flow within 20-60s by controlling synchronous generators and within a few seconds by controlling BESS’s.
- Open Access
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 42029-42043
Real Time Congestion Management Using Plug in Electric Vehicles (PEV’s): A Game Theoretic Approach
This paper presents a game-theoretic approach for solving network congestion in the Smart Grid. A smart grid environment with high penetration of Electric Vehicles (EVs) for a bidirectional power trade provides an opportunity to use the EVs for congestion management. Optimal power injected or drawn by the EV charging stations can be obtained to mitigate the congestion problem by solving a constrained optimization problem to minimize the change in the power injected at every bus while satisfying several constraints. EV charging stations will be requested to inject or draw optimal power as obtained from the optimization problem. This paper proposes a game-theoretic approach (Greed Game) to develop a smart pricing model and design a mechanism to remove congestion in the network. A unique Nash equilibrium is achieved in the game, which optimally fulfills the line power congestion management problem and yields maximum benefit for the EVs. The algorithm was applied to 16-machine 68-bus test systems, and it has been found that the proposed mechanism maximizes the gain of the EVs and solves the congestion problem in the Grid.
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 42029-42043
Open AccessReal Time Congestion Management Using Plug in Electric Vehicles (PEV’s): A Game Theoretic Approach
This paper presents a game-theoretic approach for solving network congestion in the Smart Grid. A smart grid environment with high penetration of Electric Vehicles (EVs) for a bidirectional power trade provides an opportunity to use the EVs for congestion management. Optimal power injected or drawn by the EV charging stations can be obtained to mitigate the congestion problem by solving a constrained optimization problem to minimize the change in the power injected at every bus while satisfying several constraints. EV charging stations will be requested to inject or draw optimal power as obtained from the optimization problem. This paper proposes a game-theoretic approach (Greed Game) to develop a smart pricing model and design a mechanism to remove congestion in the network. A unique Nash equilibrium is achieved in the game, which optimally fulfills the line power congestion management problem and yields maximum benefit for the EVs. The algorithm was applied to 16-machine 68-bus test systems, and it has been found that the proposed mechanism maximizes the gain of the EVs and solves the congestion problem in the Grid.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 673-678
Estimation based Maximum Power Point Control of DFIG based Wind Turbine Systems
The majority of the control schemes of doubly fed induction generator (DFIG) wind turbine systems for the maximum power capture are dependent on its internal states or functions based on these states. Thus, the availability of these states is required to implement such a control scheme in practical. But sometimes some of the states are not available (measurable) to formulate the control law. Hence, this paper recommends the estimation of such unobservable states to implement the maximum extraction control of DFIG based wind energy conversion system in practice. It is based on the estimation based control of the DFIG for the active power control for MPPT as well as the control of the stator terminal voltage. The estimation of the unobservable states have been carried out by Unscented Kalman Filter (UKF), a discrete-time nonlinear estimator. The active power and stator voltage control has been implemented through the rotor flux control approach.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 673-678
Estimation based Maximum Power Point Control of DFIG based Wind Turbine Systems
The majority of the control schemes of doubly fed induction generator (DFIG) wind turbine systems for the maximum power capture are dependent on its internal states or functions based on these states. Thus, the availability of these states is required to implement such a control scheme in practical. But sometimes some of the states are not available (measurable) to formulate the control law. Hence, this paper recommends the estimation of such unobservable states to implement the maximum extraction control of DFIG based wind energy conversion system in practice. It is based on the estimation based control of the DFIG for the active power control for MPPT as well as the control of the stator terminal voltage. The estimation of the unobservable states have been carried out by Unscented Kalman Filter (UKF), a discrete-time nonlinear estimator. The active power and stator voltage control has been implemented through the rotor flux control approach.