Tao Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hywel Morgan
School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
4 shared publications - Nicolas Gavin Green
Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK
3 shared publications David Holmes
Nanoscale Systems Integration Group, School of Electronics and Computer Science, University of Southampton, United Kingdom
1 shared publication- David Holmes
School of Electronics and Computing Science, University of Southampton, Highfield, Southampton, SO17 1BJ, UK
1 shared publication Donna Davies
Southampton General Hospital, University of Southampton, Southampton, UK
1 shared publication- Judith A. Holloway
University of Southampton, Southampton, UK
1 shared publication
Latest Publications
- 25 October 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 76 (4) , 046610
Analytical solutions of ac electrokinetics in interdigitated electrode arrays: Electric field, dielectrophoretic and traveling-wave dielectrophoretic forces
Analysis of the movement of particles in a nonuniform field requires accurate knowledge of the electric field distribution in the system. This paper describes a method for analytically solving the electric field distribution above interdigitated electrode arrays used for dielectrophoresis (DEP) and traveling wave dielectrophoresis (twDEP), using the Schwarz-Christoffel mapping method. The electric field solutions are used to calculate the dielectrophoretic force in both cases, and the traveling wave dielectrophoretic force and the electrorotational torque for the twDEP case. This method requires no approximations and can take into account the Neumann boundary condition used to represent an insulating lid and lower substrate. The analytical results of the electric field distributions are validated for different geometries by comparison with numerical simulations using the finite element method.
- 25 October 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 76 (4) , 046610
Analytical solutions of ac electrokinetics in interdigitated electrode arrays: Electric field, dielectrophoretic and traveling-wave dielectrophoretic forces
Analysis of the movement of particles in a nonuniform field requires accurate knowledge of the electric field distribution in the system. This paper describes a method for analytically solving the electric field distribution above interdigitated electrode arrays used for dielectrophoresis (DEP) and traveling wave dielectrophoresis (twDEP), using the Schwarz-Christoffel mapping method. The electric field solutions are used to calculate the dielectrophoretic force in both cases, and the traveling wave dielectrophoretic force and the electrorotational torque for the twDEP case. This method requires no approximations and can take into account the Neumann boundary condition used to represent an insulating lid and lower substrate. The analytical results of the electric field distributions are validated for different geometries by comparison with numerical simulations using the finite element method.
- 22 October 2007
- Published by Institution of Engineering and Technology (IET) in IET Nanobiotechnology
- Vol. 1 (5) , 69-79
Analytical electric field and sensitivity analysis for two microfluidic impedance cytometer designs
Microfabricated impedance cytometers have been developed to measure the electrical impedance of single biological particles at high speed. A general approach to analytically solve the electric field distributions for two different designs of cytometers: parallel facing electrodes and coplanar electrodes, using the Schwarz–Christoffel Mapping method is presented. Compared to previous analytical solutions, our derivations are more systematic and solutions are more straightforward. The solutions have been validated by comparison with numerical simulations performed using the finite element method. The influences on the electric field distribution due to the variations in the geometry of the devices have been discussed. A simple method is used to determine the impedance sensitivity of the system and to compare the two electrode designs. For identical geometrical parameters, we conclude that the parallel electrodes design is more sensitive than the coplanar electrodes.
- 22 October 2007
- Published by Institution of Engineering and Technology (IET) in IET Nanobiotechnology
- Vol. 1 (5) , 69-79
Analytical electric field and sensitivity analysis for two microfluidic impedance cytometer designs
Microfabricated impedance cytometers have been developed to measure the electrical impedance of single biological particles at high speed. A general approach to analytically solve the electric field distributions for two different designs of cytometers: parallel facing electrodes and coplanar electrodes, using the Schwarz–Christoffel Mapping method is presented. Compared to previous analytical solutions, our derivations are more systematic and solutions are more straightforward. The solutions have been validated by comparison with numerical simulations performed using the finite element method. The influences on the electric field distribution due to the variations in the geometry of the devices have been discussed. A simple method is used to determine the impedance sensitivity of the system and to compare the two electrode designs. For identical geometrical parameters, we conclude that the parallel electrodes design is more sensitive than the coplanar electrodes.
- 8 June 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (8) , 1034-1040
High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences
A novel impedance spectroscopy technique has been developed for high speed single biological particle analysis. A microfluidic cytometer is used to measure the impedance of single micrometre sized latex particles at high speed across a range of frequencies. The setup uses a technique based on maximum length sequence (MLS) analysis, where the time-dependent response of the system is measured in the time domain and transformed into the impulse response using fast M-sequence transform (FMT). Finally fast Fourier transform (FFT) is applied to the impulse response to give the transfer-function of the system in the frequency domain. It is demonstrated that the MLS technique can give multi-frequency (broad-band) measurement in a short time period (ms). The impedance spectra of polystyrene micro-beads are measured at 512 evenly distributed frequencies over a range from 976.5625 Hz to 500 kHz. The spectral information for each bead is obtained in approximately 1 ms. Good agreement is shown between the MLS data and both circuit simulations and conventional AC single frequency measurements.
- 8 June 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (8) , 1034-1040
High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences
A novel impedance spectroscopy technique has been developed for high speed single biological particle analysis. A microfluidic cytometer is used to measure the impedance of single micrometre sized latex particles at high speed across a range of frequencies. The setup uses a technique based on maximum length sequence (MLS) analysis, where the time-dependent response of the system is measured in the time domain and transformed into the impulse response using fast M-sequence transform (FMT). Finally fast Fourier transform (FFT) is applied to the impulse response to give the transfer-function of the system in the frequency domain. It is demonstrated that the MLS technique can give multi-frequency (broad-band) measurement in a short time period (ms). The impedance spectra of polystyrene micro-beads are measured at 512 evenly distributed frequencies over a range from 976.5625 Hz to 500 kHz. The spectral information for each bead is obtained in approximately 1 ms. Good agreement is shown between the MLS data and both circuit simulations and conventional AC single frequency measurements.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1452-1455
Label-Free Differential Leukocyte Counts Using a Microfabricated, Single-Cell Impedance Spectrometer
Impedance spectroscopy is a non-invasive technique which allows analysis of the electrical properties of biological cells and other materials. Typically, the electrical properties of a cell suspension are measured using relatively large volumes (>100 mul). This approach suffers from the significant drawback that the measurement is averaged over several million cells, and as such, discrimination of cell sub-population and cell sorting is impossible. We have developed a microfluidic device capable of high-speed impedance analysis of individual cells in rapid succession. In this paper, we outline the theory for impedance analysis of a single cell in a microchip. We show experimentally, the ability of the technology to distinguish, based on impedance alone, the three main leukocyte (white blood cell) sub-populations (monocytes, lymphocytes, neutrophils) in human blood. Fluorescence analysis of the cells is performed simultaneously with impedance measurement, as cells flow through the device. This provides a direct correlation between cell type (based on antibody) and impedance properties. The data shows distinct differences in the impedance properties of leukocyte sub-populations at specific frequencies.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1452-1455
Label-Free Differential Leukocyte Counts Using a Microfabricated, Single-Cell Impedance Spectrometer
Impedance spectroscopy is a non-invasive technique which allows analysis of the electrical properties of biological cells and other materials. Typically, the electrical properties of a cell suspension are measured using relatively large volumes (>100 mul). This approach suffers from the significant drawback that the measurement is averaged over several million cells, and as such, discrimination of cell sub-population and cell sorting is impossible. We have developed a microfluidic device capable of high-speed impedance analysis of individual cells in rapid succession. In this paper, we outline the theory for impedance analysis of a single cell in a microchip. We show experimentally, the ability of the technology to distinguish, based on impedance alone, the three main leukocyte (white blood cell) sub-populations (monocytes, lymphocytes, neutrophils) in human blood. Fluorescence analysis of the cells is performed simultaneously with impedance measurement, as cells flow through the device. This provides a direct correlation between cell type (based on antibody) and impedance properties. The data shows distinct differences in the impedance properties of leukocyte sub-populations at specific frequencies.