Caroline Oliveira Ribeiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Caroline Oliveira Ribeiro has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Agnaldo José Lopes
Rehabilitation Sciences Post-Graduation Program, Centro Universitário Augusto Motta (UNISUAM), Rua Dona Isabel, 94, Bonsucesso, Rio de Janeiro 21032-060, Brazil
10 shared publications - Pedro Lopes de Melo
Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil
10 shared publications - Alvaro Camilo Dias Faria
Biomedical Instrumentation Laboratory, Institute of Biology Roberto Alcantara Gomes and Laboratory of Clinical and Experimental Research in Vascular Biology (BioVasc), State University of Rio de Janeiro, Rio de Janeiro, Brazil
2 shared publications - de Sá Sousa
Instituto de Biologia, Faculdade de Engenharia, Universidade do Estado do Rio de Janeiro, Brasil
2 shared publications - Ana Lucia Ferreira de Barros
Laboratory of Experimental and Applied Physics, Centro Federal de Educação Tecnológica Celso Suckow da Fonseca, Av. Maracanã Campus 229, Rio de Janeiro 20271-110, Brazil
1 shared publication - André Luiz de Campos Pessoa
Pedro Ernesto University Hospital, State University of Rio de Janeiro, Rio de Janeiro, Brazil
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 141, 106997
Assessment of functional exercise capacity, muscle strength, fatigue, body balance, and quality of life in women with neoplasms receiving chemotherapy: Comparisons between breast and gynecological cancers
- 14 October 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 141, 106997
Open AccessAssessment of functional exercise capacity, muscle strength, fatigue, body balance, and quality of life in women with neoplasms receiving chemotherapy: Comparisons between breast and gynecological cancers
- Open Access
- 12 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-18
Multiscale Entropy Reveals Reduced Airflow Complexity in Chronic Obstructive Pulmonary Disease: Associations with Spirometry and Diagnostic Utility
Objective: To investigate the ability of multiscale entropy (MSE) methods to characterize alterations in airflow dynamics in chronic obstructive pulmonary disease (COPD) and to evaluate their associations with lung function and diagnostic performance. Methods: Spontaneous airflow signals were recorded during 150 s from 29 controls and 25 patients with COPD. Signal complexity was quantified using MSE, refined composite MSE (RCMSE), refined composite multiscale fuzzy entropy (RCMFE), and multiscale permutation entropy (MPE). The area under the entropy curve was calculated over predefined scale ranges (S 0-50 , S 50-100 , and S 0-100 ), and entropy at τ = 1 was also analyzed. Associations with spirometry and respiratory resistance (R6) were evaluated, and diagnostic performance was assessed using ROC analysis. Results: COPD patients showed a consistent reduction in airflow complexity across all entropy measures. Entropy indices were positively associated with spirometric parameters and inversely associated with R6, indicating progressive loss of complexity with increasing airway obstruction. The strongest correlations were observed at τ = 1, particularly with R6. Among multiscale indices, S 0-50 showed the strongest associations with lung function, suggesting predominant involvement of short-term airflow dynamics, consistent with small airway abnormalities in COPD. ROC analysis demonstrated high diagnostic accuracy for MSE and RCMSE (AUC > 0.90 for S 0-50 and SampEn 1 ), with comparable performance for MPE and lower accuracy for RCMFE. Conclusion: Multiscale entropy analysis of spontaneous airflow provides a sensitive, noninvasive approach for detecting and characterizing respiratory dysfunction in COPD. These methods capture clinically relevant alterations in airflow dynamics and offer complementary information to conventional lung function tests. Further studies are warranted to validate these findings and enhance their clinical applicability.
- 12 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-18
Open AccessMultiscale Entropy Reveals Reduced Airflow Complexity in Chronic Obstructive Pulmonary Disease: Associations with Spirometry and Diagnostic Utility
Objective: To investigate the ability of multiscale entropy (MSE) methods to characterize alterations in airflow dynamics in chronic obstructive pulmonary disease (COPD) and to evaluate their associations with lung function and diagnostic performance. Methods: Spontaneous airflow signals were recorded during 150 s from 29 controls and 25 patients with COPD. Signal complexity was quantified using MSE, refined composite MSE (RCMSE), refined composite multiscale fuzzy entropy (RCMFE), and multiscale permutation entropy (MPE). The area under the entropy curve was calculated over predefined scale ranges (S 0-50 , S 50-100 , and S 0-100 ), and entropy at τ = 1 was also analyzed. Associations with spirometry and respiratory resistance (R6) were evaluated, and diagnostic performance was assessed using ROC analysis. Results: COPD patients showed a consistent reduction in airflow complexity across all entropy measures. Entropy indices were positively associated with spirometric parameters and inversely associated with R6, indicating progressive loss of complexity with increasing airway obstruction. The strongest correlations were observed at τ = 1, particularly with R6. Among multiscale indices, S 0-50 showed the strongest associations with lung function, suggesting predominant involvement of short-term airflow dynamics, consistent with small airway abnormalities in COPD. ROC analysis demonstrated high diagnostic accuracy for MSE and RCMSE (AUC > 0.90 for S 0-50 and SampEn 1 ), with comparable performance for MPE and lower accuracy for RCMFE. Conclusion: Multiscale entropy analysis of spontaneous airflow provides a sensitive, noninvasive approach for detecting and characterizing respiratory dysfunction in COPD. These methods capture clinically relevant alterations in airflow dynamics and offer complementary information to conventional lung function tests. Further studies are warranted to validate these findings and enhance their clinical applicability.
- Open Access
- 1 August 2025
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 20, 2945-2965
Prediction of Abnormal Functional Performance in Chronic Obstructive Pulmonary Disease Using Respiratory Models: A Pilot Study
Introduction: The contribution of respiratory models to understanding and predicting functional capacity abnormalities in chronic obstructive pulmonary disease (COPD) has not yet been investigated. Purpose: The aims of this study were: (1) To investigate the associations between the extended Resistance-Inertance-Compliance (eRIC) and the fractional-order (FrOr) models with changes in Glittre-ADL and handgrip tests and; (2) To evaluate the accuracy of these models in predicting abnormal functional capacity in COPD. Patients and Methods: The study was carried out in a group of 40 adults with COPD and a control group of 40 healthy individuals, both evaluated by respiratory oscillometry, spirometry, Glittre-ADL test and handgrip test. eRIC and fractional order models were also used to quantify biomechanical changes and obtain physiological information. The ability of model parameters to predict abnormal functional performance was evaluated by investigating the area under the receiver operating characteristic curve (AUC). Results: Inverse relationships were observed between central airway resistance from the eRIC model and the handgrip test (p< 0.005), while respiratory compliance (C) was directly related with handgrip strength test and inversely associated with the Glittre-ADL test time (p< 0.05). The FrOr model showed direct associations among respiratory damping (G) and elastance with the Glittre-ADL test (p< 0.02), while significant inverse relationships were observed with the handgrip test (p< 0.05). Modeling parameters (peripheral resistance, total resistance and hysteresivity) achieved high prediction accuracy (AUC> 0.90) in predicting non-normal functional capacity in COPD assessed by the Glittre-ADL test. Considering abnormal changes evaluated by the handgrip test as a reference, C (AUC=0.810) and G (AUC=0.786) obtained the highest predictive accuracies. Conclusion: Parameters obtained from the eRIC and the fractional order models are associated with non-normal exercise performance in COPD and may help predict poor functional performance in these patients.
- 1 August 2025
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 20, 2945-2965
Open AccessPrediction of Abnormal Functional Performance in Chronic Obstructive Pulmonary Disease Using Respiratory Models: A Pilot Study
Introduction: The contribution of respiratory models to understanding and predicting functional capacity abnormalities in chronic obstructive pulmonary disease (COPD) has not yet been investigated. Purpose: The aims of this study were: (1) To investigate the associations between the extended Resistance-Inertance-Compliance (eRIC) and the fractional-order (FrOr) models with changes in Glittre-ADL and handgrip tests and; (2) To evaluate the accuracy of these models in predicting abnormal functional capacity in COPD. Patients and Methods: The study was carried out in a group of 40 adults with COPD and a control group of 40 healthy individuals, both evaluated by respiratory oscillometry, spirometry, Glittre-ADL test and handgrip test. eRIC and fractional order models were also used to quantify biomechanical changes and obtain physiological information. The ability of model parameters to predict abnormal functional performance was evaluated by investigating the area under the receiver operating characteristic curve (AUC). Results: Inverse relationships were observed between central airway resistance from the eRIC model and the handgrip test (p< 0.005), while respiratory compliance (C) was directly related with handgrip strength test and inversely associated with the Glittre-ADL test time (p< 0.05). The FrOr model showed direct associations among respiratory damping (G) and elastance with the Glittre-ADL test (p< 0.02), while significant inverse relationships were observed with the handgrip test (p< 0.05). Modeling parameters (peripheral resistance, total resistance and hysteresivity) achieved high prediction accuracy (AUC> 0.90) in predicting non-normal functional capacity in COPD assessed by the Glittre-ADL test. Considering abnormal changes evaluated by the handgrip test as a reference, C (AUC=0.810) and G (AUC=0.786) obtained the highest predictive accuracies. Conclusion: Parameters obtained from the eRIC and the fractional order models are associated with non-normal exercise performance in COPD and may help predict poor functional performance in these patients.
- Open Access
- 1 October 2024
- Published by Taylor & Francis in Journal of Asthma and Allergy
- Vol. ume 17, 983-1000
Oscillometry in Asthma: Respiratory Modeling and Analysis in Occupational and Work-Exacerbated Phenotypes
Background: Asthma onset or worsening of the disease in adulthood may be associated with occupational asthma (OA) or work-exacerbated asthma (WEA). Oscillometry and respiratory modeling offer insight into the pathophysiology and contribute to the early diagnosis of respiratory abnormalities. Purpose: This study aims to compare the changes due to OA and WEA and evaluate the diagnostic accuracy of this method. Patients and Methods: Ninety-nine volunteers were evaluated: 33 in the control group, 33 in the OA group, and 33 in the WEA group. The area under the receiver operator characteristic curve (AUC) was used to describe diagnostic accuracy. Results: Oscillometric analysis showed increased resistance at 4 hz (R4, p< 0.001), 20 hz (R20, p< 0.05), R4-R20 (p< 0.0001), and respiratory work (p< 0.001). Similar analysis showed reductions in dynamic compliance (p< 0.001) and ventilation homogeneity, as evaluated by resonance frequency (Fr, p< 0.0001) and reactance area (p< 0.0001). Respiratory modeling showed increased peripheral resistance (p< 0.0001), hysteresivity (p< 0.0001), and damping (p< 0.0001). No significant changes were observed comparing OA with WEA in any parameter. For OA, the diagnostic accuracy analyses showed Fr as the most accurate among oscillometric parameters (AUC=0.938), while the most accurate from respiratory modeling was hysteresivity (AUC=0.991). A similar analysis for WEA also showed that Fr was the most accurate among traditional parameters (AUC=0.972), and hysteresivity was the most accurate from modeling (AUC=0.987). The evaluation of differential diagnosis showed low accuracy. Conclusion: Oscillometry and modeling have advanced our understanding of respiratory abnormalities in OA and WEA. Furthermore, our study presents evidence suggesting that these models could aid in the early diagnosis of these diseases. Respiratory oscillometry examinations necessitate only tidal breathing and are straightforward to conduct. Collectively, these practical considerations, coupled with the findings of our study, indicate that respiratory oscillometry in conjunction with respiratory modeling, may enhance lung function assessments in OA and WEA.
- 1 October 2024
- Published by Taylor & Francis in Journal of Asthma and Allergy
- Vol. ume 17, 983-1000
Open AccessOscillometry in Asthma: Respiratory Modeling and Analysis in Occupational and Work-Exacerbated Phenotypes
Background: Asthma onset or worsening of the disease in adulthood may be associated with occupational asthma (OA) or work-exacerbated asthma (WEA). Oscillometry and respiratory modeling offer insight into the pathophysiology and contribute to the early diagnosis of respiratory abnormalities. Purpose: This study aims to compare the changes due to OA and WEA and evaluate the diagnostic accuracy of this method. Patients and Methods: Ninety-nine volunteers were evaluated: 33 in the control group, 33 in the OA group, and 33 in the WEA group. The area under the receiver operator characteristic curve (AUC) was used to describe diagnostic accuracy. Results: Oscillometric analysis showed increased resistance at 4 hz (R4, p< 0.001), 20 hz (R20, p< 0.05), R4-R20 (p< 0.0001), and respiratory work (p< 0.001). Similar analysis showed reductions in dynamic compliance (p< 0.001) and ventilation homogeneity, as evaluated by resonance frequency (Fr, p< 0.0001) and reactance area (p< 0.0001). Respiratory modeling showed increased peripheral resistance (p< 0.0001), hysteresivity (p< 0.0001), and damping (p< 0.0001). No significant changes were observed comparing OA with WEA in any parameter. For OA, the diagnostic accuracy analyses showed Fr as the most accurate among oscillometric parameters (AUC=0.938), while the most accurate from respiratory modeling was hysteresivity (AUC=0.991). A similar analysis for WEA also showed that Fr was the most accurate among traditional parameters (AUC=0.972), and hysteresivity was the most accurate from modeling (AUC=0.987). The evaluation of differential diagnosis showed low accuracy. Conclusion: Oscillometry and modeling have advanced our understanding of respiratory abnormalities in OA and WEA. Furthermore, our study presents evidence suggesting that these models could aid in the early diagnosis of these diseases. Respiratory oscillometry examinations necessitate only tidal breathing and are straightforward to conduct. Collectively, these practical considerations, coupled with the findings of our study, indicate that respiratory oscillometry in conjunction with respiratory modeling, may enhance lung function assessments in OA and WEA.
- Open Access
- 1 March 2024
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 19, 667-682
Respiratory Oscillometry and Functional Performance in Different COPD Phenotypes
Purpose: Chronic obstructive pulmonary disease (COPD) phenotypes may introduce different characteristics that need to be known to improve treatment. Respiratory oscillometry provides a detailed analysis and may offer insight into the pathophysiology of COPD. In this paper, we used this method to evaluate the differences in respiratory mechanics of COPD phenotypes. Patients and Methods: This study investigated a sample of 83 volunteers, being divided into control group (CG = 20), emphysema (n = 23), CB (n = 20) and asthma-COPD overlap syndrome (ACOS, n = 20). These analyses were performed before and after bronchodilator (BD) use. Functional capacity was evaluated using the Glittre‑ADL test, handgrip strength and respiratory pressures. Results: Initially it was observed that oscillometry provided a detailed description of the COPD phenotypes, which was consistent with the involved pathophysiology. A correlation between oscillometry and functional capacity was observed (r=− 0.541; p = 0.0001), particularly in the emphysema phenotype (r = − 0.496, p = 0.031). BD response was different among the studied phenotypes. This resulted in an accurate discrimination of ACOS from CB [area under the receiver operating curve (AUC) = 0.84] and emphysema (AUC = 0.82). Conclusion: These results offer evidence that oscillatory indices may enhance the comprehension and identification of COPD phenotypes, thereby potentially improving the support provided to these patients.
- 1 March 2024
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 19, 667-682
Open AccessRespiratory Oscillometry and Functional Performance in Different COPD Phenotypes
Purpose: Chronic obstructive pulmonary disease (COPD) phenotypes may introduce different characteristics that need to be known to improve treatment. Respiratory oscillometry provides a detailed analysis and may offer insight into the pathophysiology of COPD. In this paper, we used this method to evaluate the differences in respiratory mechanics of COPD phenotypes. Patients and Methods: This study investigated a sample of 83 volunteers, being divided into control group (CG = 20), emphysema (n = 23), CB (n = 20) and asthma-COPD overlap syndrome (ACOS, n = 20). These analyses were performed before and after bronchodilator (BD) use. Functional capacity was evaluated using the Glittre‑ADL test, handgrip strength and respiratory pressures. Results: Initially it was observed that oscillometry provided a detailed description of the COPD phenotypes, which was consistent with the involved pathophysiology. A correlation between oscillometry and functional capacity was observed (r=− 0.541; p = 0.0001), particularly in the emphysema phenotype (r = − 0.496, p = 0.031). BD response was different among the studied phenotypes. This resulted in an accurate discrimination of ACOS from CB [area under the receiver operating curve (AUC) = 0.84] and emphysema (AUC = 0.82). Conclusion: These results offer evidence that oscillatory indices may enhance the comprehension and identification of COPD phenotypes, thereby potentially improving the support provided to these patients.
- 4 January 2024
- Published by Springer Nature
- p. 345-354
A Portable Low-Cost Device for Respiratory Rate Monitoring in COVID-19, Persistent Post-COVID and Other Severe Respiratory Syndromes
- 4 January 2024
- Published by Springer Nature
- p. 345-354
A Portable Low-Cost Device for Respiratory Rate Monitoring in COVID-19, Persistent Post-COVID and Other Severe Respiratory Syndromes
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 56, e12898
Respiratory oscillometry and functional analyses in patients with idiopathic scoliosis
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 56, e12898
Open AccessRespiratory oscillometry and functional analyses in patients with idiopathic scoliosis
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.
- Open Access
- 1 May 2022
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 17, 1017-1030
Respiratory Oscillometry in Chronic Obstructive Pulmonary Disease: Association with Functional Capacity as Evaluated by Adl Glittre Test and Hand Grip Strength Test
Purpose: Respiratory oscillometry has emerged as a powerful method for detecting respiratory abnormalities in COPD. However, this method has not been widely introduced into clinical practice. This limitation arises, at least in part, because the clinical meaning of the oscillometric parameters is not clear. In this paper, we evaluated the association of oscillometry with functional capacity and its ability to predict abnormal functional capacity in COPD. Patients and Methods: This cross-sectional study investigated a control group formed by 30 healthy subjects and 30 outpatients with COPD. The subjects were classified by the Glittre‑ADL test and handgrip strength according to the functional capacity. Results: This study has shown initially that subjects with abnormal functional capacity had a higher value for resistance (p < 0.05), reactance area (Ax, p < 0.01), impedance modulus (Z4, p < 0.05), and reduced dynamic compliance (Cdyn, p < 0.05) when compared with subjects with normal functional capacity. This resulted in significant and consistent correlations among resistive oscillometric parameters (R=− 0.43), Cdyn (R=− 0.40), Ax (R = 0.42), and Z4 (R = 0.41) with exercise performance. Additionally, the effects of exercise limitation in COPD were adequately predicted, as evaluated by the area under the curve (AUC) obtained by receiver operating characteristic analysis. The best parameters for this task were R4-R20 (AUC = 0.779) and Ax (AUC = 0.752). Conclusion: Respiratory oscillometry provides information related to functional capacity in COPD. This method is also able to predict low exercise tolerance in these patients. These findings elucidate the physiological and clinical meaning of the oscillometric parameters, improving the interpretation of these parameters in COPD patients.
- 1 May 2022
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 17, 1017-1030
Open AccessRespiratory Oscillometry in Chronic Obstructive Pulmonary Disease: Association with Functional Capacity as Evaluated by Adl Glittre Test and Hand Grip Strength Test
Purpose: Respiratory oscillometry has emerged as a powerful method for detecting respiratory abnormalities in COPD. However, this method has not been widely introduced into clinical practice. This limitation arises, at least in part, because the clinical meaning of the oscillometric parameters is not clear. In this paper, we evaluated the association of oscillometry with functional capacity and its ability to predict abnormal functional capacity in COPD. Patients and Methods: This cross-sectional study investigated a control group formed by 30 healthy subjects and 30 outpatients with COPD. The subjects were classified by the Glittre‑ADL test and handgrip strength according to the functional capacity. Results: This study has shown initially that subjects with abnormal functional capacity had a higher value for resistance (p < 0.05), reactance area (Ax, p < 0.01), impedance modulus (Z4, p < 0.05), and reduced dynamic compliance (Cdyn, p < 0.05) when compared with subjects with normal functional capacity. This resulted in significant and consistent correlations among resistive oscillometric parameters (R=− 0.43), Cdyn (R=− 0.40), Ax (R = 0.42), and Z4 (R = 0.41) with exercise performance. Additionally, the effects of exercise limitation in COPD were adequately predicted, as evaluated by the area under the curve (AUC) obtained by receiver operating characteristic analysis. The best parameters for this task were R4-R20 (AUC = 0.779) and Ax (AUC = 0.752). Conclusion: Respiratory oscillometry provides information related to functional capacity in COPD. This method is also able to predict low exercise tolerance in these patients. These findings elucidate the physiological and clinical meaning of the oscillometric parameters, improving the interpretation of these parameters in COPD patients.
- Open Access
- 1 December 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 3273-3289
Oscillation Mechanics, Integer and Fractional Respiratory Modeling in COPD: Effect of Obstruction Severity
Purpose: This research examines the emerging role of respiratory oscillometry associated with integer (InOr) and fractional order (FrOr) respiratory models in the context of groups of patients with increasing severity. The contributions to our understanding of the respiratory abnormalities along the course of increasing COPD severity and the diagnostic use of this method were also evaluated. Patients and Methods: Forty-five individuals with no history of smoking or pulmonary diseases (control group) and 141 individuals with diagnoses of COPD were studied, being classified into 45 mild, 42 moderate, 36 severe and 18 very severe cases. Results: This study has shown initially that the course of increasing COPD severity was adequately described by the model parameters. This resulted in significant and consistent correlations among these parameters and spirometric indexes. Additionally, this evaluation enhanced our understanding of the respiratory abnormalities in different COPD stages. The diagnostic accuracy analyses provided evidence that hysteresivity, obtained from FrOr modeling, allowed a highly accurate identification in patients with mild changes [area under the receiver operator characteristic curve (AUC)= 0.902]. Similar analyses in groups of moderate and severe patients showed that peripheral resistance, derived from InOr modeling, provided the most accurate parameter (AUC=0.898 and 0.998, respectively), while in very severe patients, traditional, InOr and FrOr parameters were able to reach high diagnostic accuracy (AUC> 0.9). Conclusion: InOr and FrOr modeling improved our knowledge of the respiratory abnormalities along the course of increasing COPD severity. In addition, the present study provides evidence that these models may contribute in the diagnosis of COPD. Respiratory oscillometry exams require only tidal breathing and are easy to perform. Taken together, these practical considerations and the results of the present study suggest that respiratory oscillometry associated with InOr and FrOr models may help to improve lung function tests in COPD.
- 1 December 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 3273-3289
Open AccessOscillation Mechanics, Integer and Fractional Respiratory Modeling in COPD: Effect of Obstruction Severity
Purpose: This research examines the emerging role of respiratory oscillometry associated with integer (InOr) and fractional order (FrOr) respiratory models in the context of groups of patients with increasing severity. The contributions to our understanding of the respiratory abnormalities along the course of increasing COPD severity and the diagnostic use of this method were also evaluated. Patients and Methods: Forty-five individuals with no history of smoking or pulmonary diseases (control group) and 141 individuals with diagnoses of COPD were studied, being classified into 45 mild, 42 moderate, 36 severe and 18 very severe cases. Results: This study has shown initially that the course of increasing COPD severity was adequately described by the model parameters. This resulted in significant and consistent correlations among these parameters and spirometric indexes. Additionally, this evaluation enhanced our understanding of the respiratory abnormalities in different COPD stages. The diagnostic accuracy analyses provided evidence that hysteresivity, obtained from FrOr modeling, allowed a highly accurate identification in patients with mild changes [area under the receiver operator characteristic curve (AUC)= 0.902]. Similar analyses in groups of moderate and severe patients showed that peripheral resistance, derived from InOr modeling, provided the most accurate parameter (AUC=0.898 and 0.998, respectively), while in very severe patients, traditional, InOr and FrOr parameters were able to reach high diagnostic accuracy (AUC> 0.9). Conclusion: InOr and FrOr modeling improved our knowledge of the respiratory abnormalities along the course of increasing COPD severity. In addition, the present study provides evidence that these models may contribute in the diagnosis of COPD. Respiratory oscillometry exams require only tidal breathing and are easy to perform. Taken together, these practical considerations and the results of the present study suggest that respiratory oscillometry associated with InOr and FrOr models may help to improve lung function tests in COPD.