de Sá Sousa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
de Sá Sousa has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Agnaldo José Lopes
Rehabilitation Sciences Post-Graduation Program, Centro Universitário Augusto Motta (UNISUAM), Rua Dona Isabel, 94, Bonsucesso, Rio de Janeiro 21032-060, Brazil
2 shared publications - Caroline Oliveira Ribeiro
Biomedical Instrumentation Laboratory, Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, Brazil
2 shared publications - Pedro Lopes de Melo
Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil
2 shared publications - André Luiz de Campos Pessoa
Pedro Ernesto University Hospital, State University of Rio de Janeiro, Rio de Janeiro, Brazil
1 shared publication Cíntia Moraes
1 shared publicationEduarda Martins
1 shared publication
Latest Publications
- Open Access
- 12 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-18
Multiscale Entropy Reveals Reduced Airflow Complexity in Chronic Obstructive Pulmonary Disease: Associations with Spirometry and Diagnostic Utility
Objective: To investigate the ability of multiscale entropy (MSE) methods to characterize alterations in airflow dynamics in chronic obstructive pulmonary disease (COPD) and to evaluate their associations with lung function and diagnostic performance. Methods: Spontaneous airflow signals were recorded during 150 s from 29 controls and 25 patients with COPD. Signal complexity was quantified using MSE, refined composite MSE (RCMSE), refined composite multiscale fuzzy entropy (RCMFE), and multiscale permutation entropy (MPE). The area under the entropy curve was calculated over predefined scale ranges (S 0-50 , S 50-100 , and S 0-100 ), and entropy at τ = 1 was also analyzed. Associations with spirometry and respiratory resistance (R6) were evaluated, and diagnostic performance was assessed using ROC analysis. Results: COPD patients showed a consistent reduction in airflow complexity across all entropy measures. Entropy indices were positively associated with spirometric parameters and inversely associated with R6, indicating progressive loss of complexity with increasing airway obstruction. The strongest correlations were observed at τ = 1, particularly with R6. Among multiscale indices, S 0-50 showed the strongest associations with lung function, suggesting predominant involvement of short-term airflow dynamics, consistent with small airway abnormalities in COPD. ROC analysis demonstrated high diagnostic accuracy for MSE and RCMSE (AUC > 0.90 for S 0-50 and SampEn 1 ), with comparable performance for MPE and lower accuracy for RCMFE. Conclusion: Multiscale entropy analysis of spontaneous airflow provides a sensitive, noninvasive approach for detecting and characterizing respiratory dysfunction in COPD. These methods capture clinically relevant alterations in airflow dynamics and offer complementary information to conventional lung function tests. Further studies are warranted to validate these findings and enhance their clinical applicability.
- 12 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-18
Open AccessMultiscale Entropy Reveals Reduced Airflow Complexity in Chronic Obstructive Pulmonary Disease: Associations with Spirometry and Diagnostic Utility
Objective: To investigate the ability of multiscale entropy (MSE) methods to characterize alterations in airflow dynamics in chronic obstructive pulmonary disease (COPD) and to evaluate their associations with lung function and diagnostic performance. Methods: Spontaneous airflow signals were recorded during 150 s from 29 controls and 25 patients with COPD. Signal complexity was quantified using MSE, refined composite MSE (RCMSE), refined composite multiscale fuzzy entropy (RCMFE), and multiscale permutation entropy (MPE). The area under the entropy curve was calculated over predefined scale ranges (S 0-50 , S 50-100 , and S 0-100 ), and entropy at τ = 1 was also analyzed. Associations with spirometry and respiratory resistance (R6) were evaluated, and diagnostic performance was assessed using ROC analysis. Results: COPD patients showed a consistent reduction in airflow complexity across all entropy measures. Entropy indices were positively associated with spirometric parameters and inversely associated with R6, indicating progressive loss of complexity with increasing airway obstruction. The strongest correlations were observed at τ = 1, particularly with R6. Among multiscale indices, S 0-50 showed the strongest associations with lung function, suggesting predominant involvement of short-term airflow dynamics, consistent with small airway abnormalities in COPD. ROC analysis demonstrated high diagnostic accuracy for MSE and RCMSE (AUC > 0.90 for S 0-50 and SampEn 1 ), with comparable performance for MPE and lower accuracy for RCMFE. Conclusion: Multiscale entropy analysis of spontaneous airflow provides a sensitive, noninvasive approach for detecting and characterizing respiratory dysfunction in COPD. These methods capture clinically relevant alterations in airflow dynamics and offer complementary information to conventional lung function tests. Further studies are warranted to validate these findings and enhance their clinical applicability.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 56, e12898
Respiratory oscillometry and functional analyses in patients with idiopathic scoliosis
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 56, e12898
Open AccessRespiratory oscillometry and functional analyses in patients with idiopathic scoliosis
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.