Alexander Prokhorov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander Prokhorov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
A. V. Murthy
Aero-Tech, Inc., Hampton, Virginia 23666-5528
1 shared publication- Boris B. Khlevnoy
All-Russian Research Institute for Optical and Physical Measurements
1 shared publication - Dorothy DeWitt
Faculty of Education, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication E. N. Simonov
1 shared publicationMikhail L Samoilov
Russian Institute for Opto-Physical Measurements (Russia)
1 shared publicationNina I. Prokhorova
Virial International, LLC, 538 Palmspring Dr., Gaithersburg, Maryland 20878, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2021
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University. Series "Mathematical Modelling, Programming and Computer Software"
- Vol. 14 (1) , 104-117
Algorithm of Reconstruction of Three-Dimensional Images in X-Ray Computed Tomography with a Cone Beam
- 1 January 2021
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University. Series "Mathematical Modelling, Programming and Computer Software"
- Vol. 14 (1) , 104-117
Open AccessAlgorithm of Reconstruction of Three-Dimensional Images in X-Ray Computed Tomography with a Cone Beam
- 7 January 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (2-3) , 252-266
Alternative Methods of Blackbody Thermodynamic Temperature Measurement Above Silver Point
- 7 January 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (2-3) , 252-266
Alternative Methods of Blackbody Thermodynamic Temperature Measurement Above Silver Point
- 20 November 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (33) , 8003-8012
Application of the three-component bidirectional reflectance distribution function model to Monte Carlo calculation of spectral effective emissivities of nonisothermal blackbody cavities
We applied the bidirectional reflectance distribution function (BRDF) model consisting of diffuse, quasi-specular, and glossy components to the Monte Carlo modeling of spectral effective emissivities for nonisothermal cavities. A method for extension of a monochromatic three-component (3C) BRDF model to a continuous spectral range is proposed. The initial data for this method are the BRDFs measured in the plane of incidence at a single wavelength and several incidence angles and directional–hemispherical reflectance measured at one incidence angle within a finite spectral range. We proposed the Monte Carlo algorithm for calculation of spectral effective emissivities for nonisothermal cavities whose internal surface is described by the wavelength-dependent 3C BRDF model. The results obtained for a cylindroconical nonisothermal cavity are discussed and compared with results obtained using the conventional specular–diffuse model.
- 20 November 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (33) , 8003-8012
Application of the three-component bidirectional reflectance distribution function model to Monte Carlo calculation of spectral effective emissivities of nonisothermal blackbody cavities
We applied the bidirectional reflectance distribution function (BRDF) model consisting of diffuse, quasi-specular, and glossy components to the Monte Carlo modeling of spectral effective emissivities for nonisothermal cavities. A method for extension of a monochromatic three-component (3C) BRDF model to a continuous spectral range is proposed. The initial data for this method are the BRDFs measured in the plane of incidence at a single wavelength and several incidence angles and directional–hemispherical reflectance measured at one incidence angle within a finite spectral range. We proposed the Monte Carlo algorithm for calculation of spectral effective emissivities for nonisothermal cavities whose internal surface is described by the wavelength-dependent 3C BRDF model. The results obtained for a cylindroconical nonisothermal cavity are discussed and compared with results obtained using the conventional specular–diffuse model.
- 1 May 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (13) , 2322-2332
Effective emissivities of isothermal blackbody cavities calculated by the Monte Carlo method using the three-component bidirectional reflectance distribution function model
This paper proposes a three-component bidirectional reflectance distribution function (3C BRDF) model consisting of diffuse, quasi-specular, and glossy components for calculation of effective emissivities of blackbody cavities and then investigates the properties of the new reflection model. The particle swarm optimization method is applied for fitting a 3C BRDF model to measured BRDFs. The model is incorporated into the Monte Carlo ray-tracing algorithm for isothermal cavities. Finally, the paper compares the results obtained using the 3C model and the conventional specular-diffuse model of reflection.
- 1 May 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (13) , 2322-2332
Effective emissivities of isothermal blackbody cavities calculated by the Monte Carlo method using the three-component bidirectional reflectance distribution function model
This paper proposes a three-component bidirectional reflectance distribution function (3C BRDF) model consisting of diffuse, quasi-specular, and glossy components for calculation of effective emissivities of blackbody cavities and then investigates the properties of the new reflection model. The particle swarm optimization method is applied for fitting a 3C BRDF model to measured BRDFs. The model is incorporated into the Monte Carlo ray-tracing algorithm for isothermal cavities. Finally, the paper compares the results obtained using the 3C model and the conventional specular-diffuse model of reflection.
- 1 July 2004
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 18 (3) , 333-341
High Heat-Flux Sensor Calibration: A Monte Carlo Modeling
Conventional calibration of heat-flux sensors uses high-temperature blackbody radiation and places the sensors away from the blackbody aperture. This approach limits the achievable calibration heat flux to about 50 kW/m2. Recent interest in extension of the calibration to higher heat-flux levels requires placement the sensors inside the heated cavity under nearly hemispherical irradiation environment. The incident flux at the sensor location depends on the effective emissivity, which is a function of the combined cavity and sensor geometry, and the properties of the radiating surfaces. A scheme is presented to compute the effective emissivity for such measurement schemes by the use of the Monte Carlo technique. Typical results presented demonstrate the influence of the cavity wall surface emissivity and diffusity, nonuniform temperature distributions, and the sensor location on the calculated effective emissivity. The computations show that the optimum location for the sensor is at a distance of about one cavity radius from the cavity bottom. The effective emissivity at this location has a high value, even in the presence of a linear wall-temperature variation, and is relatively insensitive to the cavity-wall temperature gradient. The use of a reflecting shield to increase the effective emissivity is also investigated.
- 1 July 2004
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 18 (3) , 333-341
High Heat-Flux Sensor Calibration: A Monte Carlo Modeling
Conventional calibration of heat-flux sensors uses high-temperature blackbody radiation and places the sensors away from the blackbody aperture. This approach limits the achievable calibration heat flux to about 50 kW/m2. Recent interest in extension of the calibration to higher heat-flux levels requires placement the sensors inside the heated cavity under nearly hemispherical irradiation environment. The incident flux at the sensor location depends on the effective emissivity, which is a function of the combined cavity and sensor geometry, and the properties of the radiating surfaces. A scheme is presented to compute the effective emissivity for such measurement schemes by the use of the Monte Carlo technique. Typical results presented demonstrate the influence of the cavity wall surface emissivity and diffusity, nonuniform temperature distributions, and the sensor location on the calculated effective emissivity. The computations show that the optimum location for the sensor is at a distance of about one cavity radius from the cavity bottom. The effective emissivity at this location has a high value, even in the presence of a linear wall-temperature variation, and is relatively insensitive to the cavity-wall temperature gradient. The use of a reflecting shield to increase the effective emissivity is also investigated.
- 11 August 1998
- Published by SPIE-Intl Soc Optical Eng
- p. 247-258
Modeling, design, and characterization of medium-background blackbodies for full-aperture calibration of spaceborne infrared systems and imagers
Two extended area reference blackbodies, covering temperature range from 100 K to 900 K, have been designed and built by VNIIOFI and Vega International, Inc., for German Institute of Space Sensor Technology. The design objectives were to develop Plankian sources for high accuracy IR calibrations; provide, where possible, both high vacuum and atmospheric operation capabilities for easier achievable calibration traceability; and attain compact design to serve as a portable transfer standard. Target technical specifications for the low temperature blackbody BB100 include 100 mm full aperture, +/- 12 degree viewing angles, 0.999 effective spectral emissivity in 3 micrometers to 15 micrometers band, 100 K to 450 K temperature range, 50 mK temperature uniformity across aperture and, finally, 30 mK temperature setting/measurement accuracy. An employed design was selected after conceptual design study, which involved extensive thermophysical modeling and optimization. A finite element method has been applied to calculation of temperature distribution. Effective emissivity simulation was realized by the Monte Carlo method. The result of computer modeling of temperature distributions and effective emissivity are presented. Both target specifications and results of BB characterization are provided. Results of investigation confirm validity of selected approach and assumptions. Possibilities of further improvement of blackbodies performance are discussed.
- 11 August 1998
- Published by SPIE-Intl Soc Optical Eng
- p. 247-258
Modeling, design, and characterization of medium-background blackbodies for full-aperture calibration of spaceborne infrared systems and imagers
Two extended area reference blackbodies, covering temperature range from 100 K to 900 K, have been designed and built by VNIIOFI and Vega International, Inc., for German Institute of Space Sensor Technology. The design objectives were to develop Plankian sources for high accuracy IR calibrations; provide, where possible, both high vacuum and atmospheric operation capabilities for easier achievable calibration traceability; and attain compact design to serve as a portable transfer standard. Target technical specifications for the low temperature blackbody BB100 include 100 mm full aperture, +/- 12 degree viewing angles, 0.999 effective spectral emissivity in 3 micrometers to 15 micrometers band, 100 K to 450 K temperature range, 50 mK temperature uniformity across aperture and, finally, 30 mK temperature setting/measurement accuracy. An employed design was selected after conceptual design study, which involved extensive thermophysical modeling and optimization. A finite element method has been applied to calculation of temperature distribution. Effective emissivity simulation was realized by the Monte Carlo method. The result of computer modeling of temperature distributions and effective emissivity are presented. Both target specifications and results of BB characterization are provided. Results of investigation confirm validity of selected approach and assumptions. Possibilities of further improvement of blackbodies performance are discussed.