Maneesh Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maneesh Kumar has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Sachidananda Sen
SR University
5 shared publications Sachidananda Sen
4 shared publications- Barjeev Tyagi
Electrical Engineering Department, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
3 shared publications Arvind Kumar Prajapati
2 shared publicationsBarjeev Tyagi
Department of Electrical Engineering, IIT Roorkee, Roorkee, India
2 shared publications- Pravin Kumar
Indian Institute of Technology Roorkee
2 shared publications
Latest Publications
- 14 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Experimentally validated ANN-based sustainable fault diagnosis framework for solar PV systems
- 14 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Experimentally validated ANN-based sustainable fault diagnosis framework for solar PV systems
- 18 June 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
THERMO-ELECTRICAL PERFORMANCE ASSESSMENT OF PHOTOVOLTAIC THERMAL (PVT) SYSTEM USING HYBRID AND MONO-NANOFLUIDS
The objective of the study is to investigate the thermo-electrical performance of photovoltaic thermal (PVT) system under varying volume fraction and mass flow rate (MFR) of various nanofluids such as Cu–water, TiO2–water, and Cu–TiO2–water hybrid nanofluid (HNF) as coolants. An HNF is the combination of different nanoparticles mixed in different proportions in the base fluid. The numerical investigation is carried out on the hourly solar irradiance and ambient temperature data for Ghaziabad city, India (28.6692∘N, 77.4538∘E). The outcome of the investigation shows that the thermo-electrical performance improves significantly as the MFR and volume concentration of nanoparticles in the base fluid increase. Using Cu–TiO2–water nanofluid, the average cell temperature obtained is 33.95∘C, while using TiO2–water nanofluid and Cu-water nanofluid, the average cell temperature is 40.52∘C and 35.68∘C, respectively. The average electrical efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF is 12.91%, 13.34%, and 13.55%, respectively. The average thermal efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF coolant is 34.23%, 38.72%, and 39.76%, respectively. Further, increasing the MFR of HNF from 0.02[ ]kg/s to 0.1[ ]kg/s, the average cell temperature reduces by 9.2%, correspondingly enhancing the electrical efficiency.
- 18 June 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
THERMO-ELECTRICAL PERFORMANCE ASSESSMENT OF PHOTOVOLTAIC THERMAL (PVT) SYSTEM USING HYBRID AND MONO-NANOFLUIDS
The objective of the study is to investigate the thermo-electrical performance of photovoltaic thermal (PVT) system under varying volume fraction and mass flow rate (MFR) of various nanofluids such as Cu–water, TiO2–water, and Cu–TiO2–water hybrid nanofluid (HNF) as coolants. An HNF is the combination of different nanoparticles mixed in different proportions in the base fluid. The numerical investigation is carried out on the hourly solar irradiance and ambient temperature data for Ghaziabad city, India (28.6692∘N, 77.4538∘E). The outcome of the investigation shows that the thermo-electrical performance improves significantly as the MFR and volume concentration of nanoparticles in the base fluid increase. Using Cu–TiO2–water nanofluid, the average cell temperature obtained is 33.95∘C, while using TiO2–water nanofluid and Cu-water nanofluid, the average cell temperature is 40.52∘C and 35.68∘C, respectively. The average electrical efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF is 12.91%, 13.34%, and 13.55%, respectively. The average thermal efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF coolant is 34.23%, 38.72%, and 39.76%, respectively. Further, increasing the MFR of HNF from 0.02[ ]kg/s to 0.1[ ]kg/s, the average cell temperature reduces by 9.2%, correspondingly enhancing the electrical efficiency.
- Top Cited PapersOpen Access
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 84541-84554
Reliability Issues and Degradation Mechanisms of p-GaN Gated E-Mode AlGaN/GaN Power HEMTs: A Critical Review
GaN-HEMTs on silicon (Si) or SiC or sapphire substrates are growing in popularity and is expected to completely transform the power electronics industry. Although GaN HEMTs operate in D-Mode by default, E-Mode operation is necessary for ease of IC design, low power consumption and safe operation. p-GaN gated HEMTs offer a breakdown voltage (V ${}_{\mathrm {BR}}$ ), transconductance (g ${}_{\mathrm {m}}$ ), power added efficiency (PAE) and ON-current (I ${}_{\mathrm {ON}}$ ) of over 2230 V, 205 mS/mm, 55.4 % and 1 A/mm, respectively, which makes them highly suitable for future RF-power switching applications. The time-dependent breakdown of the AlGaN-p-GaN/metal stack (due to avalanche multiplication) is a serious reliability concern in p-GaN HEMTs. Material defects, back gate effects, gate leakage, bias stress effects, ESD & short circuit failures, radiation effects and thermal effects are also important reliability concerns that can result in performance degradation, including current collapse, reduced breakdown voltage, increased on-resistance and device failure. Mechanisms like interface states, ion migration, and electron trapping are also crucial to the aging of p-GaN HEMTs. Understanding these reliability issues and degradation mechanisms is critical for enhancing the robustness of p-GaN HEMTs in power electronics and RF applications. Therefore, this article reviews the reliability issues and various degradation mechanisms of p-GaN gated E-Mode HEMTs such as forward/reverse bias stress effects, back gate effects, current collapse, charge trapping effects, radiation effects, short circuit (SC) & electrostatic discharge (ESD) failures and high temperature reliability issues. RON degradation, gate breakdown, PBTI and NBTI remains serious concerns in the development of p-GaN gated E-Mode HEMTs for future consumer electronics, wireless networks, industrial motors, electric vehicles and space/aeronautic applications.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 84541-84554
Top Cited PapersOpen AccessReliability Issues and Degradation Mechanisms of p-GaN Gated E-Mode AlGaN/GaN Power HEMTs: A Critical Review
GaN-HEMTs on silicon (Si) or SiC or sapphire substrates are growing in popularity and is expected to completely transform the power electronics industry. Although GaN HEMTs operate in D-Mode by default, E-Mode operation is necessary for ease of IC design, low power consumption and safe operation. p-GaN gated HEMTs offer a breakdown voltage (V ${}_{\mathrm {BR}}$ ), transconductance (g ${}_{\mathrm {m}}$ ), power added efficiency (PAE) and ON-current (I ${}_{\mathrm {ON}}$ ) of over 2230 V, 205 mS/mm, 55.4 % and 1 A/mm, respectively, which makes them highly suitable for future RF-power switching applications. The time-dependent breakdown of the AlGaN-p-GaN/metal stack (due to avalanche multiplication) is a serious reliability concern in p-GaN HEMTs. Material defects, back gate effects, gate leakage, bias stress effects, ESD & short circuit failures, radiation effects and thermal effects are also important reliability concerns that can result in performance degradation, including current collapse, reduced breakdown voltage, increased on-resistance and device failure. Mechanisms like interface states, ion migration, and electron trapping are also crucial to the aging of p-GaN HEMTs. Understanding these reliability issues and degradation mechanisms is critical for enhancing the robustness of p-GaN HEMTs in power electronics and RF applications. Therefore, this article reviews the reliability issues and various degradation mechanisms of p-GaN gated E-Mode HEMTs such as forward/reverse bias stress effects, back gate effects, current collapse, charge trapping effects, radiation effects, short circuit (SC) & electrostatic discharge (ESD) failures and high temperature reliability issues. RON degradation, gate breakdown, PBTI and NBTI remains serious concerns in the development of p-GaN gated E-Mode HEMTs for future consumer electronics, wireless networks, industrial motors, electric vehicles and space/aeronautic applications.
- 1 October 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (3) , 1559-1594
Order Reduction of Real Time Electromechanical Systems by Using a New Model Order Reduction Method and Controller Design
- 1 October 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (3) , 1559-1594
Order Reduction of Real Time Electromechanical Systems by Using a New Model Order Reduction Method and Controller Design
- 12 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 83, 396-409
A comprehensive techno-economic analysis for hydrogen fuel-cell supported HEVs using predictive control approach
- 12 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 83, 396-409
A comprehensive techno-economic analysis for hydrogen fuel-cell supported HEVs using predictive control approach
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4870-4887
An Adaptive Fuzzy Controller-Based Distributed Voltage Control Strategy for a Remote Microgrid System With Solar Energy and Battery Support
This paper presents a robust decentralized voltage control strategy for a remote microgrid (rMG) system. The proposed decentralized voltage control strategy is applied to a voltage source inverter (VSI) through a pulse width modulation (PWM) technique. To implement the strategy, a small-scale remote microgrid test system is considered, supported by solar photovoltaic (SPV) and battery energy storage system (BSS). The two sources are connected through a common inverter connected to a three-phase system. Maximum power extraction is considered from the SPV system using an MPPT-based algorithm. The output voltage of the common inverter is maintained by triggering the inverter circuit in a controlled way using the PWM technique. BSS charging and discharging are also controlled through a controller circuit. The uncertainty in the solar irradiance data is captured through a series of variations with different slew rates. The output voltage VSI is controlled using an adaptive fuzzy PID controller (AFPID). This controller eliminates the need for the optimal adaptation gain value for robust control. The VSI voltage control is achieved by considering the peak value of the three-phase AC voltage as a reference, and a closed-loop dq control is implemented. The results are analyzed under various system conditions, and a comparative assessment is obtained with other control schemes such as dual-loop PID, model reference adaptive controller (MRAC), and APID controller. It is observed that the AFPID provides better voltage control and stability to the system as compared to other control schemes. The overall performance of the proposed fuzzy controller is investigated with the help of various performance indices.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4870-4887
An Adaptive Fuzzy Controller-Based Distributed Voltage Control Strategy for a Remote Microgrid System With Solar Energy and Battery Support
This paper presents a robust decentralized voltage control strategy for a remote microgrid (rMG) system. The proposed decentralized voltage control strategy is applied to a voltage source inverter (VSI) through a pulse width modulation (PWM) technique. To implement the strategy, a small-scale remote microgrid test system is considered, supported by solar photovoltaic (SPV) and battery energy storage system (BSS). The two sources are connected through a common inverter connected to a three-phase system. Maximum power extraction is considered from the SPV system using an MPPT-based algorithm. The output voltage of the common inverter is maintained by triggering the inverter circuit in a controlled way using the PWM technique. BSS charging and discharging are also controlled through a controller circuit. The uncertainty in the solar irradiance data is captured through a series of variations with different slew rates. The output voltage VSI is controlled using an adaptive fuzzy PID controller (AFPID). This controller eliminates the need for the optimal adaptation gain value for robust control. The VSI voltage control is achieved by considering the peak value of the three-phase AC voltage as a reference, and a closed-loop dq control is implemented. The results are analyzed under various system conditions, and a comparative assessment is obtained with other control schemes such as dual-loop PID, model reference adaptive controller (MRAC), and APID controller. It is observed that the AFPID provides better voltage control and stability to the system as compared to other control schemes. The overall performance of the proposed fuzzy controller is investigated with the help of various performance indices.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2390-2408
Distributed-MPC Type Optimal EMS for Renewables and EVs Based Grid-Connected Building Integrated Microgrid
The vision of smart cities are being realized gradually by converting each building into a smart building. These are cyber-physical systems meant to provide best comfort to its habitant at most economical and environmentally sustainable way. There can be multiple loads for heating, cooling, lighting purposes. Renewables such as rooftop solar photovoltaic and small-scale wind turbines are also integrated for generating electricity that reduces the grid-dependency. This forms a Building Integrated Microgrid (BIMG) system consisting of its own sources, storage, and loads. Handling intermittent generation, variable load conditions, and external grid dynamics are the three essential factors to increase buildings’ smartness. In this work, an adaptive Distributed Model Predictive Control (DMPC) principle for energy management of renewables based grid-tied BIMG is presented. All possible arbitrages, viz., generation intermittency of renewables, time-variable load profiles, storage unit's charging and discharging cycles, interruption of non-critical loads, and dynamic pricing of grid energy are considered. The feasibility of the given strategy is validated by realizing extensive test cases over 24 hrs duration using variable profiles of solar irradiance, continuous dynamic load variation at small and large scale, interruption of non-critical loads, two-tier tariff, and battery longevity by accounting for smooth charging/discharging cycles on the MATLAB software and Real-Time Digital Simulator (RTDS) based Hardware-in-Loop (HIL) setup.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2390-2408
Distributed-MPC Type Optimal EMS for Renewables and EVs Based Grid-Connected Building Integrated Microgrid
The vision of smart cities are being realized gradually by converting each building into a smart building. These are cyber-physical systems meant to provide best comfort to its habitant at most economical and environmentally sustainable way. There can be multiple loads for heating, cooling, lighting purposes. Renewables such as rooftop solar photovoltaic and small-scale wind turbines are also integrated for generating electricity that reduces the grid-dependency. This forms a Building Integrated Microgrid (BIMG) system consisting of its own sources, storage, and loads. Handling intermittent generation, variable load conditions, and external grid dynamics are the three essential factors to increase buildings’ smartness. In this work, an adaptive Distributed Model Predictive Control (DMPC) principle for energy management of renewables based grid-tied BIMG is presented. All possible arbitrages, viz., generation intermittency of renewables, time-variable load profiles, storage unit's charging and discharging cycles, interruption of non-critical loads, and dynamic pricing of grid energy are considered. The feasibility of the given strategy is validated by realizing extensive test cases over 24 hrs duration using variable profiles of solar irradiance, continuous dynamic load variation at small and large scale, interruption of non-critical loads, two-tier tariff, and battery longevity by accounting for smooth charging/discharging cycles on the MATLAB software and Real-Time Digital Simulator (RTDS) based Hardware-in-Loop (HIL) setup.