  • Enhancing Transient Response of Grid Connected DFIG-WT Through Adaptive Inertia and Damping Control With Virtual Synchronous

    by Shwetank Agrawal, Barjeev Tyagi, Vishal Kumar, Pawan Sharma

    This paper presents the virtual synchronous (VSync) approach with adaptive inertia and damping control (AIDC) for a doubly fed induction generator (DFIG) based wind turbine (WT) connected with the grid to enhance the transient response. The proposed control strategy provides virtual inertia and damping regulation under transient conditions. The VSync method incorporates the swing equation of a synchronous generator (SG), facilitating the synchronization of the DFIG-WT without needing a phase-locked loop (PLL). A rotor flux-based modeling approach for the DFIG is developed to implement the control action. Reactive power is regulated through appropriate rotor flux magnitude control. Active power control is achieved by adjusting the angle of internal voltage generated by the VSync using the AIDC method. The reactive power reference is defined from the inverse Q−V droop to support the voltage regulation at the DFIG-WT terminal. However, the speed controller defines the active power reference, where the speed reference is defined by the wind turbine de-loading graph. The proposed method helps to enhance the rate of change of frequency (ROCOF) and improves the frequency nadir. A time domain analysis is performed to demonstrate the superiority of the proposed control among the vector control (VC), constant parameter control (CPC), and adaptive inertia control (AIC). Further, the controller hardwarein-loop (CHIL) is performed to validate the DFIG-WT response under transient conditions.


  • Operation and Control of Parallel-Operated Interlinking Converter in Hybrid Microgrid

    by Shwetank Agrawal, Barjeev Tyagi, Vishal Kumar, Pawan Sharma

    This paper presents the operation and stability of parallel-operated interlinking converters (ILCs) in a hybrid microgrid (HMG). The hierarchical control strategy, consisting of primary and secondary control, is used to regulate HMG. Primary control utilizes droop control for power sharing on AC and DC buses, while secondary control restores AC frequency and DC/AC bus voltages. The ILCs are controlled using hybrid and inverse Q −V droop with low-pass filters (LPFs) to mitigate high-frequency noise, ensuring efficient power exchange between AC and DC sections. The literature review reveals the need for the model development and testing of the parallel-operated ILC in HMG consisting of primary and secondary control. Hence, a linearized small-signal model consisting of primary and secondary control for HMG has been proposed. The model incorporates AC, DC, and ILC dynamics to analyze the power flow and stability of the system. An eigenvalue analysis is performed to assess the impact of the droop coefficients, providing insight into stability enhancement. Time-domain simulations evaluate transient behaviors under disturbances, and the controller hardware-in-loop (CHIL) platform is used to validate the dynamic response. The findings demonstrate the stability of HMG and the critical role of ILCs in enabling power transfer, akin to inter-area tie-lines in conventional systems


  • Open Access

    Experimental Validation of FOPI Controllers and Modelling of DC Motor for Robotics Applications

    by Pravin Kumar, Vishal Kumar, Barjeev Tyagi

    This work introduces the modelling of the DC servo motor for robotics applications. For the modelled system, it proposes the fractional-order proportional-integral controller. The analysis of different components of the modular servo system has been stated. Various transient responses, like overshoot, steady-state error, delay time, etc., have been considered to evaluate the performance of the proposed controller for the modelled system. The proposed controller has been simulated for various ranges of gain to assess stability. In the last, the experimental validations of the proposed model for the various proportional-integral controllers have also been carried out for the comparative analysis, and the found results are significantly superior.

  • Digital Controller Design and Implementation for AC and DC Side of 3ph qZSI

    by Shwetank Agrawal, Barjeev Tyagi, Vishal Kumar, Pawan Sharma

    This paper presents the multi-loop digital controller design of a quasi-z-source inverter (qZSI). The qZSI is a single-stage power converter and can operate in buck and boost modes. The qZSI is an economical solution for distributed generation and eliminates the need for two-stage power conversion. This paper proposes a detailed step-wise digital controller design using a multi-loop control method. The controllers of the AC and DC sides are designed separately. A proportional controller is used for the inner current control loop on both the AC and DC sides. In contrast, for outer voltage loop control, the proportional and resonant (PR) controller is used on the AC side, and the proportional and integral (PI) is used on the DC side. In designing the digital controllers, the effect of the sensor gain and low pass filter (LPF) in the feedback path is also considered. Furthermore, to mimic the behavior of the synchronous generator, the droop control is used to generate the reference voltage for the AC side of the controller. The time domain simulations are carried out to verify the designed controllers. Experimental results are also presented for the validation of the proposed controllers.


  • Fault Detection Technique for Distribution Networks and Microgrids Using Synchrophasor Data

    by Gagandeep Singh Dua, Barjeev Tyagi, Vishal Kumar

    Integration of distributed energy resources in distribution networks encourages the use of advanced measurement devices such as micro-phasor measurement units ( $\mu$ PMUs) to develop monitoring, protection, automation and control applications. Modern distribution networks have the capability to function as a microgrid and operate in multiple configurations with hourly reconfiguration. Detection of faults in these networks is challenging due to numerous reasons. Therefore, this paper presents a technique to detect the symmetrical and asymmetrical faults in the distribution networks and microgrids using time-series measurements from $\mu$ PMUs deployed at various locations. The network operating in multi-configuration is partitioned into zones between adjacent $\mu$ PMUs. The combination of two criteria, namely the voltage deviation index and power change index, is determined for each zone, and their product is used to accomplish the exercise of fault detection. Simulation results are obtained on a seven-bus microgrid network for various fault and no-fault scenarios to validate the proposed fault detection algorithm. The proposed scheme is also assessed for the effect of network reconfiguration, measurement noise, intermittency of distributed energy resources, and harmonics in the system. In addition, verification in the RTDS environment is done through simulations on a modified IEEE 33-node distribution network deployed with GTNET-PMUs.


  • Microgrid Differential Protection Based on Superimposed Current Angle Employing Synchrophasors

    by Gagandeep Singh Dua, Barjeev Tyagi, Vishal Kumar

    The inclusion of multi-energy distributed generators (DGs), especially inverter-interfaced generators, presents challenges in the microgrid's protection strategy and operational constraints. The work for designing primary protection mechanism for microgrid is continuously progressing. In this regard, this article presents a positive sequence superimposed current differential angle based protection scheme employing only positive sequence current phasor from both ends of the line. The proposed scheme collects current phasor measurements from the low-cost microphasor measurement units ( $\mu$ PMUs). The performance of the proposed scheme is analyzed through simulations on a seven-node microgrid in grid-connected and isolated mode operation under various fault and no-fault situations, and also considering the effect of DG penetration level and DGs types. The simulations are also carried out in the IEEE-33 node network considering C37.118.1 standards-compliant PMUs. Furthermore, a real-time control hardware-in-loop testing is performed to further validate the scheme for practical implementation.


  • PV Modelling and Fuzzy PI Control of Stand Alone Photovoltaic with Battery Storage Backup

    by Pravin Kumar, Vishal Kumar, Barjeev Tyagi

    This article proposes a fuzzy-PI controller for controlling the DC link voltage of a stand-alone microgrid test system. Within this work, the mathematical modelling of PV is determined to assess the P-V and I-V characteristics of PV. The MPPT controller is utilized Perturb & Observe algorithm to generate the maximum power of PV. The proposed controller is simulated for the five various operating cases. The results which are obtained by the proposed controller is compared with the existing method.


  • Change in Sum of Power Based Fault Detection Method for Microgrid Utilizing μPMU

    by Gagandeep Singh Dua, Barjeev Tyagi, Vishal Kumar

    This article presents a method to detect the short-circuit faults in the microgrid by processing and analyzing $\mu$ PMU data. The $\mu$ PMUs are placed in the network for fault observability, and the network is divided into monitoring zones. Thereafter, a fault detection index is developed that computes the change in the per-unit sum of positive sequence active power entering the zone. Extensive test scenarios are simulated on a microgrid system for the grid-connected and islanded mode of operation to verify the proposed scheme. Besides that, validation on several no-fault scenarios such as capacitor and load switching, distributed generator tripping, microgrid islanding, and resynchronization is performed. Across the wide range of operating conditions, the test results indicate that the proposed method reliably detects faults in the microgrid.

  • Sequence-Based Hybrid Technique for Islanding Detection for Microgrid With RES

    by Pravin Kumar, Vishal Kumar, Barjeev Tyagi

    In this work, the detection of islanding of a microgrid having different types of RES (DGs) has been presented. It proposes a technique that uses two new developed criteria; i) Discrimination factor of islanding (DFI) and ii) Superimposed angle of positive sequence impedance ( $\Delta {\phi _{1Z}}$ ), for the true discrimination between islanding and non-islanding events. The technique utilizes the developed criteria in hybridization to complement each other. The efficacy of the proposed hybrid technique has been tested on a 7-bus microgrid test system for illustration and has also been verified on a modified IEEE 34 bus system. All the simulations have been carried out in the RTDS/RSCAD environment. The proposed technique distinguishes the islanding from non-islanding events in the 9 ms even at the 0\% power mismatch; therefore, restricts the undesirable tripping due to the various kinds of non-islanding events. The islanding has been determined considering each type of DGs as targeted DG in various cases. A comparison of the obtained results has also been performed with the existing methods to show the superiority of the proposed technique. The effects of quality factor of load, sampling frequency and noise have also been studied.


  • PMU-Based Voltage Stability Measurement Under Contingency Using ANN

    by Sanjay Kumar, Barjeev Tyagi, Vishal Kumar, Sunita Chohan

    An artificial neural network (ANN) is an effective and efficient approach for solving problems, which require fast and complicated computation. The study proposed a PMU measurement-based voltage stability monitoring and assessment using ANN hybrid model for the evaluation of voltage stability margin. Particle swarm optimization (PSO) optimizes the meta-parameter of ANNs for improving its convergence rate. This model helps in real-time monitoring of long-term voltage stability to avoid grid blackout. The power system security is generally defined based on the single contingency “N−1” criterion, meaning normal system minus one element. Separate ANNs are trained and designed for selected worst case “N−1” contingencies along with base case configuration. Phasor Measurement Unit installed at distant locations provide real-time synchronized measurements of voltage phasor, which forms the input feature for the proposed model. Load $P$ margin evaluated by continuation power flow (CPF) method is considered as output feature of the proposed ANN model. The performance indices mean absolute percentage error (MAPE) and maximum percentage error (MPE) with smaller values indicate small deviation between the estimated and the actual values. The proposed approach is effectively tested on IEEE 14-bus and 30-bus test system.