JMJaligam Murali Mohan

Jaligam Murali Mohan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jaligam Murali Mohan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Sanket Goel

    Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad, India

    5 shared publications
  • Satish Kumar Dubey

    Birla Institute of Technology and Science (BITS) Pilani

    4 shared publications
  • Arshad Javed

    Department of Mechanical Engineering, Birla Institute of Technology and Science, Hyderabad, 500078, India; MEMS, Microfluidics and Nano Electronics Laboratory, Birla Institute of Technology and Science, Hyderabad, 500078, India

    3 shared publications
  • Khairunnisa Amreen

    Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India

    3 shared publications
  • Arshad Javed

    BITS-Pilani, Hyderabad Campus,Mechanical Engineering Department,Hyderabad,India

    2 shared publications
  • Khairunnisa Amreen

    Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Hyderabad, 500078, India; MEMS, Microfluidics and Nano Electronics Laboratory, Birla Institute of Technology and Science, Hyderabad, 500078, India

    2 shared publications

Latest Publications

  • Open Access

    Enhanced antibacterial efficacy: rapid analysis of silver-decorated azithromycin-infused Soluplus® nanoparticles against E. coli and S. epidermidis biofilms

    by Murali Mohan Jaligam, Chisato Takahashi, Benjamin Heidt, Amy Q. Shen

    The escalating threat of antibiotic-resistant bacterial biofilms necessitates innovative antimicrobial strategies. This study introduces silver-decorated, azithromycin- Soluplus® nanoparticles (Ag-AZI-Sol NPs), synthesized via a controlled emulsion diffusion method to ensure sustained release of antimicrobial silver ions for over six hours—a critical factor for continuous antibacterial efficacy. The efficacy of these nanoparticles was evaluated against biofilms formed by Escherichia coli (E. coli) and Staphylococcus epidermidis (S. epidermidis), pathogens that cause hospital-acquired infections. Concentrations of 5 and 10 µg/mL, Ag-AZI-Sol NPs induced significant morphological changes within biofilms, disrupting the bacterial extracellular matrix as observed using scanning electron microscopy (SEM). This disruption peaked between two and six hours, coinciding with damage to bacterial cells by silver ions. Antibacterial assay measurements and optical density (OD) confirmed a significant reduction in growth rate among Ag-AZI-Sol NPs treated bacteria compared with controls. Electrochemical analysis using laser-induced graphene (LIG) and chronoamperometry revealed a decline in current, indicating an effective antibacterial effect. This innovative biosensing technique makes use of the high conductivity and huge surface area of LIG to detect changes in bacterial activity quickly and sensitively. Our findings highlight the potent microbicidal properties of Ag-AZI-Sol NPs and suggest diverse applications from food processing to medical device coatings.


  • Disposable Paper-Based Miniaturized Device for Sensing of Phthalates

    by Jaligam Murali Mohan, Sanjeet Kumar, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    One of the most frequent plasticizers that can cause endocrine disruption is phthalates. The phthalates are utilized in the production of consumer plastic items, leading to increase the risk of exposure of the items stored in water bottles, beverage drinks and food. Further, bioaccumulation and harmful consequences amongst animal life is also prevalent. Therefore, detection of phthalates over a period of time is crucial in food safety and quality. The present work aims to develop a point-of-care, screen-printed, disposable paper device, for detection of phthalates. The device was integrated with buckypaper for efficient detection of phthalates. Primarily, phthalates response was analyzed in the standard three-electrode system where the buckypaper was used as a working electrode. Further, a paper device was fabricated using screen-printing approach and the device was tested for phthalates sensing. The traditional approach and the screen-printed device exhibited a very similar electrocatalytic oxidation of phthalates at E = -0.25 V using the miniaturized portable Potentiostat. Hence, can be used for point-of-care analysis. Subsequently, various electrochemical parameters were also examined. The device provided a linear range of 70 ppm to 15 ppm with a detection limit of 12.64 ppm and quantification limit as 42.03 ppm. Finally, the device was validated for repeatability and stability. As the analysis for real time sensing, local tap water was used with the standard addition method and the recovery percentages were remarkable. Based on the promising results and benchmarked form-factor, this device has the potential to be used as point-of-care testing platform.


  • Microfluidic Device Integrated With PDMS Microchannel and Unmodified ITO Glass Electrodes for Highly Sensitive, Specific, and Point-of-Care Detection of Copper and Mercury

    by Jaligam Murali Mohan, Sohan Dudala, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    This work delves upon developing a two-layer plasma-bonded microfluidic device with a microchannel layer and electrodes for electroanalytical detection of heavy metal ions. The three-electrode system was realized on an ITO-glass slide by suitably etching the ITO layer with the help of CO 2 laser. The microchannel layer was fabricated using a PDMS soft-lithography method wherein the mold created by maskless lithography. The optimized dimensions opted to develop a microfluidic device with length of 20 mm, width of 0.5 mm and gap of 1 mm. The device, with bare unmodified ITO electrodes, was tested to detect Cu and Hg by a portable potentiostat connected with a smartphone. The analytes were introduced in the microfluidic device with a peristaltic pump at an optimal flow rate of 90 μL/min. The device exhibited sensitive electro-catalytic sensing of both the metals by achieving an oxidation peak at -0.4 V and 0.1 V for Cu and Hg respectively. Furthermore, square wave voltammetry (SWV) approach was used to analyze the scan rate effect and concentration effect. The device also used to simultaneously detect both the analytes. During simultaneous sensing of Hg and Cu, the linear range was observed between 2 μM to 100 μM, the limit of detection (LOD) was found to be 0.04 μM and 3.19 μM for Cu and Hg respectively. Further, no interference with other co-existing metal ions was found manifesting the specificity of the device to Cu and Hg. Finally, the device was successfully tested with real samples like tap water, lake water, and serum with remarkable recovery percentages. Such portable devices pave way for detecting various heavy metal ions in a point-of-care environment. The developed device can also be used for detection of other heavy metals like cadmium, lead, zinc etc., by modifying the working electrode with the various nanocomposites.


  • Optimized ink jetted paper device for electroanalytical detection of picric acid

    by Jaligam Murali Mohan, Khairunnisa Amreen, Madhusudan B. Kulkarni, Arshad Javed, Satish Kumar Dubey, Sanket Goel


  • Electrochemical Mini-Platform With Thread- Based Electrodes for Interference Free Arsenic Detection

    by Jaligam Murali Mohan, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    Herein, a fully integrated thread/textile-based electrochemical sensing device has been demonstrated. A hydrophilic conductive carbon thread, chemically modified with gold nanoparticles through an electrodeposition process, was used as a working electrode (WE). The hydrophilic thread coated with Ag/AgCl and an unmodified bare hydrophilic thread were used as reference electrode (RE) and counter electrode (CE) respectively. The device was fabricated with hydrophilic conductive carbon threads supported by capillary tubes and these integrated electrodes were placed in a 2 mL glass vial. The physico-chemical characterization of the working electrode was carried out using SEM (scanning electron microscopy) and X-ray photoelectron spectroscopy (XPS). Furthermore, the fabricated sensing platform, was tested for electrochemical sensing of arsenic. The electrocatalytic oxidation activity of arsenic in the designed platform was investigated via cyclic voltammetry (CV) and square wave Voltammetry (SWV). An oxidation peak at −0.4 V corresponding to the oxidation of arsenic was obtained. Scan rate effect was performed using CV analysis and the diffusion coefficient was found to be $2.478\times 10^{-10}$ with a regression coefficient of R 2 = 0.9647. Further, concentration effect was accomplished in the linear range $0.4~\mu $ M to $60~\mu $ M. The limit of detection was obtained as $0.416~\mu $ M. For the practical application, effect of interference from other chemicals and real sample analysis from the tap water and blood serum sample was carried out which gave remarkable recovery values.


  • Highly Selective Electrochemical Sensing of Dopamine, Xanthine, Ascorbic Acid and Uric Acid Using a Carbon Fiber Paper

    by Jaligam Murali Mohan, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    Biological compounds like Dopamine (D), Xanthine (X), Ascorbic acid (AA) and Uric acid (UA) play a vital role in food, clinical and human metabolism. Since these compounds are present in biological fluids and have close standard potentials values, it is imperative to choose a method to sense these fluids without any electrochemical interference. Toray paper, with a porous gas diffusion layer imbibed with denser carbon fibers, is an excellent option that can be utilized as a working electrode for such sensing applications. Herein, the electroactivity of these compounds was tested using cyclic voltammetry and square wave voltammetry without any interference. The linear ranges for the compounds (D, X, AA, UA) are 10-1000 μlM, 7-300 μM, 100-1000 μM and 30-1000 μM respectively, while the limits of detection are 9.67 μM, 6.54 μM, 97.12 μM and 28.74 μM respectively with S/N ratio of 1.5. Finally, the electrode was tested with human serum samples for the identification of D, X, AA and UA manifesting exceptional reproducibility.