Michael Heijnemans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Heijnemans has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Armin Jafari
Power and Wide-Band-Gap Electronics Research Laboratory, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
1 shared publication - Elison Matioli
Power and Wide-band-gap Electronics Research Laboratory (POWERlab), Institute of Electrical and Micro Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
1 shared publication - Enea Figini
Distributed Electrical Systems Laboratory (DESL) -STI-IEL EPFL -DESL ELL 116 (Bâtiment ELL) Station 11 CH-1015 Lausanne
1 shared publication - Furkan Karakaya
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication - Mohammad Samizadeh Nikoo
Nanyang Technological University
1 shared publication - Remco van Erp
Power and Wide-Band-Gap Electronics Research Laboratory, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
1 shared publication
Latest Publications
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 23-28
High-Accuracy Calibration-Free Calorimeter for the Measurement of Low Power Losses
Wide-band-gap technologies enable ultra-high efficiencies in high-frequency power conversion. However, inadequate accuracies in electrical measurements could lead to spurious efficiency measurements, even above 100%. Furthermore, bandwidth limitations, particularly for current probing, delay mismatches between current and voltage probes, loading effects and electromagnetic interferences make electrical techniques inappropriate for measuring extremely-low losses in switches with high dv/dt and di/dt values and magnetic components with high-frequency excitations. Calorimetric methods overcome this issue by a direct loss measurement through the generated heat. Nevertheless, limited ranges and accuracies of existing systems hinder their application in sensitive measurements. Moreover, time-consuming calibrations with extensive data processing impede rapid design assessments. In this work, we propose a closed-type double-chamber calorimeter based on a real-time calibration between two identical chambers, to eliminate extra compensation for ambient variations or changes within the system itself. By streaming the same coolant in both chambers, our system removes the need for flow measurements, enabling extremely low flow rates which improves sensitivity and reduces complexity and system cost. The system provides adjustable cooling and can measure losses down to 500 mW, enabling the evaluation of high-performance power converters and their components with no dependencies on the geometries of the evaluated devices or systems.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 23-28
High-Accuracy Calibration-Free Calorimeter for the Measurement of Low Power Losses
Wide-band-gap technologies enable ultra-high efficiencies in high-frequency power conversion. However, inadequate accuracies in electrical measurements could lead to spurious efficiency measurements, even above 100%. Furthermore, bandwidth limitations, particularly for current probing, delay mismatches between current and voltage probes, loading effects and electromagnetic interferences make electrical techniques inappropriate for measuring extremely-low losses in switches with high dv/dt and di/dt values and magnetic components with high-frequency excitations. Calorimetric methods overcome this issue by a direct loss measurement through the generated heat. Nevertheless, limited ranges and accuracies of existing systems hinder their application in sensitive measurements. Moreover, time-consuming calibrations with extensive data processing impede rapid design assessments. In this work, we propose a closed-type double-chamber calorimeter based on a real-time calibration between two identical chambers, to eliminate extra compensation for ambient variations or changes within the system itself. By streaming the same coolant in both chambers, our system removes the need for flow measurements, enabling extremely low flow rates which improves sensitivity and reduces complexity and system cost. The system provides adjustable cooling and can measure losses down to 500 mW, enabling the evaluation of high-performance power converters and their components with no dependencies on the geometries of the evaluated devices or systems.